Hostname: page-component-6898cfcb55-zkb6p Total loading time: 0 Render date: 2026-11-11T05:27:51.085Z Has data issue: false hasContentIssue false

Experimental non-Boussinesq fountains

Published online by Cambridge University Press:  09 November 2015

Rabah Mehaddi*
Affiliation:
Aix-Marseille Université, Laboratoire IUSTI, UMR CNRS 7343, 5 rue Enrico Fermi, 13 453 Marseille, CEDEX 13, France
Olivier Vauquelin
Affiliation:
Aix-Marseille Université, Laboratoire IUSTI, UMR CNRS 7343, 5 rue Enrico Fermi, 13 453 Marseille, CEDEX 13, France
Fabien Candelier
Affiliation:
Aix-Marseille Université, Laboratoire IUSTI, UMR CNRS 7343, 5 rue Enrico Fermi, 13 453 Marseille, CEDEX 13, France
*
†Email address for correspondence: rabah.mehaddi@univ-lorraine.fr

Abstract

Laboratory experiments involving downward air–helium fountains are presented. The large density differences between these releases and the ambient allow us to investigate how non-Boussinesq effects modify fountain heights and fountain fluctuations in comparison with the Boussinesq case (i.e. marginal density differences). In these experiments, the source Froude number is varied over a wide range covering (i) the very weak, (ii) the weak and (iii) the forced fountain regimes. It is shown that the classical Boussinesq correlations can be extended to the non-Boussinesq case provided that the Froude number is multiplied by the square root of the ratio between the released fluid density and that of the ambient. In the range investigated, no influence of the source Reynolds number is observed.

Information

Type
Rapids
Copyright
© 2015 Cambridge University Press 
Figure 0

Figure 1.Schematic of the different steps of the development of a typical turbulent fountain: (a) initial up-flow, (b) steady state.

Figure 1

Figure 2.Schematic of the experimental apparatus: $1$, air source; $2$, helium source; $3$, flow meters; $4$, hydrochloric acid; $5$, ammoniac; $6$, plenum chamber; $7$, rectangular panel; $8$, laser sheet; $9$, CCD camera.

Figure 2

Figure 3.Instantaneous snapshots of (a) a stable fountain ($Fr=1$, $Re=570$ and ${\it\rho}_{i}/{\it\rho}_{0}=0.95$) and (b) a fluctuating fountain ($Fr=14$, $Re=1770$ and ${\it\rho}_{i}/{\it\rho}_{0}=0.44$).

Figure 3

Figure 4.Comparisons between the present experimental results for the mean height $H_{m}$ and the correlations by Burridge & Hunt (2012): solid line, $H_{m}/b_{i}=2.46Fr$; dashed line, $H_{m}/b_{i}=0.86Fr^{2}$; dash-dotted line, $H_{m}/b_{i}=0.81Fr^{2/3}$. The experimental data points $(\circ )$ are shaded according to the density ratio ${\it\rho}_{i}/{\it\rho}_{0}$.

Figure 4

Figure 5.Determination from experimental data $(\circ )$ the corrective function associated with the density ratio ${\it\rho}_{i}/{\it\rho}_{0}$. The solid line represents the best fit, with a slope of $1/2$, and the dashed line, whose slope is $3/4$, represents the solution derived from the Morton-like model (see appendix A). The dash-dotted line corresponds to the Boussinesq case.

Figure 5

Figure 6.Ratio between the dimensionless fountain height and its corresponding correlation as a function of the source Reynolds number.

Figure 6

Figure 7.Comparisons between the experimental results obtained for the fountain mean height $H_{m}$ and the following correlations: solid line, $H_{m}/b_{i}=2.58Fr_{NB}$; dashed line, $H_{m}/b_{i}=1.4Fr_{NB}^{2}$; dash-dotted line, $H_{m}/b_{i}=1.1Fr_{NB}^{2/3}$. The data points $(\circ )$ are shaded according to the density ratio ${\it\rho}_{i}/{\it\rho}_{0}$.

Figure 7

Figure 8.Variation of the standard deviation ${\it\delta}z$ as a function of the non-Boussinesq Froude number $Fr_{NB}$. The best-fit line (solid line) is given by (4.4). The experimental data points $(\circ )$ are shaded according to the density ratio ${\it\rho}_{i}/{\it\rho}_{0}$.

Figure 8

Table 1.Flow regime and the associated correlations for the mean fountain height as a function of the non-Boussinesq Froude number.

Figure 9

Figure 9.Variation of the Strouhal number $St$ as a function of the non-Boussinesq Froude number $Fr_{NB}$. The experimental data points $(\circ )$ are shaded according to the density ratio ${\it\rho}_{i}/{\it\rho}_{0}$.