Hostname: page-component-74656f9884-6grmk Total loading time: 0 Render date: 2026-11-06T09:00:54.891Z Has data issue: false hasContentIssue false

A new density filter for pipes for fluid topology optimization

Published online by Cambridge University Press:  30 April 2024

Young Hun Choi
Affiliation:
School of Mechanical Engineering, Hanyang University, Seoul, 04763, South Korea
Gil Ho Yoon*
Affiliation:
School of Mechanical Engineering, Hanyang University, Seoul, 04763, South Korea
*
†Email address for correspondence: ghy@hanyang.ac.kr

Abstract

This study presents a new density filter for a pipe-shaped structure and its application to fluid topology optimization. A simple and straight pipe-shaped structure for fluid is preferred for many engineering purposes rather than the perplex manifold structure provided by the topology optimization method. To determine an optimal pipe structure for fluid, we develop a new density filter and apply it to fluid topology optimization. Hence, the original spatially varying design variables of the fluid topology optimization are modified based on the pipe density filter. Subsequently, the filter design variables, including a uniform pipe wall thickness and adjusted cross-section, are used for artificial pseudo-rigid bodies in fluid topology optimization. An additional constraint is imposed to maintain a nearly uniform pipe thickness. Several numerical examples are solved to demonstrate the validity of the present pipe density filter for fluid topology optimization problems minimizing the energy dissipation of the fluid and controlling the particles suspended in the fluid.

Information

Type
JFM Papers
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. Concept of the pipe density filter and its application to fluid problems. (a) Conventional fluid topology optimization, (b) pipe structure, (c) two topology optimizations with the pipe density filter and (d) pipe wall thickness and pipe cross-sectional thickness.

Figure 1

Figure 2. Process of the pipe density filter. (a) Pipe-shaped structure in fluid related problems, (b) pipe density filter and (c) process of the pipe density filter in one dimension.

Figure 2

Figure 3. (a) Each step of the process of the pipe density filter and (b) examples of the pipe density filter ($p = 6, a = -30, b = 0.5$ and design domain $= 100 \times 100$).

Figure 3

Figure 4. Process of designing a pipe with a uniform thickness. (a) Schematic drawing of the maximum thickness constraint and (b) schematic drawing of a uniformly thick pipe.

Figure 4

Figure 5. Pipe design without density filtering with a radius of $r_{{thick}}$. (a) Schematic drawing and (b) an example of the difficulty of controlling the pipe cross-sectional thickness using only the maximum thickness constraint.

Figure 5

Figure 6. Optimization process using the pipe density filter.

Figure 6

Figure 7. Example 1. (a) Problem definition of fluid topology optimization for the diffuser (${\alpha _{max}} = {10^{10}}$, $n = 3$, input velocity: ${{\boldsymbol {u}}_{{{in}}}} = (u, 0)$, $u = - {u_{max }}( {y - 0.0048} )( {y - 0.0252} )$, ${u_{max }} = 1.80625\ \textrm {m}\ \textrm {s}^{-1}$, fluid properties: density = $1\ \textrm {kg}\ \textrm {m}^{-3}$ and viscosity = $1\ \textrm {{Pa}} \times \textrm {{s}}$), (b) an optimized result of the conventional fluid topology optimization and (c) the fluid velocity (the volume of the structure: 55 % and the dissipation energy: 319.4 W).

Figure 7

Figure 8. Optimization result with the pipe density filter in figure 7 (the pipe volume: 45 % of the design domain, the objective: 326.2 W and the density filter: $p=6, a=-30, b=0.5$, ${\tau _{{{thick}}}} = 1.2$). (a) Optimized design ${\boldsymbol {\gamma }}_{{p}}$, (b) design variables ${\boldsymbol {\gamma }}$ and (c) fluid velocity in the optimized design.

Figure 8

Figure 9. Optimized layouts, objectives, streamlines and fluid velocities with different parameters ($a$, $b$, ${\tau _{{{thick}}}}$) in figure 8.

Figure 9

Figure 10. Optimization histories of figure 9: (a) $a=-60$, $b=0.1$, ${\tau _{{{thick}}}=1.5}$ pixels, (b) $a=-30$, $b=0.5$, ${\tau _{{{thick}}}=1.5}$ pixels, (c) $a=-30$, $b=0.5$, ${\tau _{{{thick}}}=2.5}$ pixels and (d) $a=-30$, $b=0.5$, ${\tau _{{{thick}}}=3.5}$ pixels.

Figure 10

Figure 11. Example 2. A fluid topology optimization problem with one inlet and two outlets. (a) Problem definition ($L = 0.03$ m, ${\alpha _{max }} = {10^{10}}$, $n = 3$, input velocity: ${{\boldsymbol {u}}_{{{in}}}} = (u, 0)$, $u = - {u_{max }}( {y - 2L/5} )( {y - 3L/5} )$, ${u_{max }} = 0.1\ \textrm {m}\ \textrm {s}^{-1}$, fluid properties: density = $1\ \textrm {kg}\ \textrm {m}^{-3}$ and viscosity $= 1\ \textrm {Pa} \times \textrm {s}$), (b) an optimized result of conventional fluid topology optimization (volume of the structure: 50 %) and (c) fluid velocity (the objective $= 6.352\times 10^{-2}~\textrm {{{W}}}$).

Figure 11

Figure 12. Optimized result of fluid topology optimization without the thickness constraint (parameters of the density filter: $p=6, a=-30, b=0.5$, ${\tau _{{{{thick}}}}} = 1.5$, volume of the inner pipe: 50 %). (a) Pipe filtered variables, (b) design variables and (c) fluid velocity (the objective $= 6.616\times 10^{-2}\ \textrm {W}$).

Figure 12

Figure 13. Result with unnecessary structures obtained by optimization with the maximum thickness constraint (radius of the density filter $= 9.5$ pixels, ${r_{{cross}}} = 10.5$ pixels, $p=6, a=-30, b=0.5$, ${\tau _{{{{thick}}}}} = 1.5$, volume of the inner pipe: 50 %, the objective $=0.1810~\textrm {{{W}}}$). (a) An optimized design, (b) design variables, (c) density filtered design and (d) fluid velocity.

Figure 13

Figure 14. Example of the unnecessary structure.

Figure 14

Figure 15. Optimized results of fluid topology optimization with the pipe density filter, maximum thickness constraint and penalty term (${r_{{thick}}} = 9.5$ pixels, $\beta = 10^{-7}$, $p=6, a=-30, b=0.5$, ${\tau _{{{{thick}}}}} = 1.5$ and volume of the inner pipe: 50 %). (a) A result with $r_{{cross}}$ value of 10.5 pixels (the modified objective $=0.18190$ W, dissipated power $= 0.18188$ W), (b) a result with $r_{{cross}}$ value of 15.5 pixels (the modified objective $=6.9548 \times 10^{-2}$ W, dissipated power $=6.9437 \times 10^{-2}$ W) and (c) their optimization histories.

Figure 15

Figure 16. Example 3. (a) Problem definition of the separation of the three particles (${\alpha _{max }} = {10^{10}}$, $n = 4$, ${t_f} = 8\ \textrm {s}$, $\Delta t=10^{-5}$ s, ${u_{max }} = 0.02\ \textrm {m}\ \textrm {s}^{-1}$, fluid properties: density = $1000\ \textrm {kg}\ \textrm {m}^{-3}$ and viscosity $= 5 \times {10^{ - 3}}\ \textrm {{Pa}} \times \textrm {{s}}$, properties of the particles: $F_D$ = $200$, $40$ and $20\ ({{{\textrm {N}} \times {\textrm {s}}}})\ ({{{\textrm {kg}} \times {\textrm {m}}}})^{-1}$), (b) an optimized result without the pipe density filter (Choi & Yoon 2023) and (c) fluid velocity.

Figure 16

Figure 17. Optimized result with the pipe density filter (the ${\textrm {margin}} = 0.0025\ {\textrm {m}}$ (5 pixels), volume fraction of pipe: $0.45$ and parameters of the density filter: $p=6, a=-30, b=0.5$, ${r_{{thick}}} = 3.9$, ${\tau _{{{thick}}}} = 1.5$). (a) An optimized design, (b) design variables, (c) density filtered design and (d) fluid velocity.

Figure 17

Figure 18. Optimization history of figure 17.

Figure 18

Figure 19. Example 4. Optimized results with the pipe density filter and thickness constraint (${r_{{thick}}} = 5.5$ pixels, ${r_{{cross}}} = 6.5$ pixels, the ${{margin}} = 0.0035\ {\textrm {m}}$ (7 pixels), ${\tau _{{{{thick}}}}} = 1.5$, $p=6, a=-30, b=0.5$). Optimized pipe results and optimization histories with $\beta$ values of (a) $10^{-7}$ and (b) $10^{-8}$.