Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-08T10:39:54.228Z Has data issue: false hasContentIssue false

Transcarotid balloon aortic valvuloplasty for critical aortic stenosis in an infant weighing 890 g

Published online by Cambridge University Press:  16 November 2020

Naomi Nakagawa*
Affiliation:
Department of Pediatric Cardiology, Hiroshima City Hospital, Hiroshima, Japan
Masahiro Kamada
Affiliation:
Department of Pediatric Cardiology, Hiroshima City Hospital, Hiroshima, Japan
Yuji Moritoh
Affiliation:
Department of Pediatric Cardiology, Hiroshima City Hospital, Hiroshima, Japan
*
Author for correspondence: N. Nakagawa, MD, PhD, Department of Pediatric Cardiology, Hiroshima City Hospital, 7-33 Naka-ku Moto-machi, Hiroshima City, Hiroshima 730-8518, Japan. Tel.: +81 82 2291. E-mail: polonekogorogoro@dream.com
Rights & Permissions [Opens in a new window]

Abstract

We report the smallest case of the balloon aortic valvuloplasty via a carotid artery. A baby boy weighing 890 g suffered from a severe aortic stenosis. Balloon aortic valvuloplasty using a TMP-Ped 4-mm balloon catheter succeeded in resolving severe aortic stenosis without any complications. Balloon aortic valvuloplasty via a carotid artery can be a first-line treatment even for extremely-low-birth-weight infants.

Information

Type
Brief Report
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
© The Author(s), 2020. Published by Cambridge University Press
Figure 0

Figure 1. A simulative schema of balloon aortic valvuloplasty using ultrasound finding. The image of the balloon was put on this ultrasound image to know the length of sheath which can be inserted into the artery. aAo = Ascending aorta; AoV = Aortic valve; RCCA = right common carotid artery.

Figure 1

Figure 2. Balloon aortic valvuloplasty using a 4 × 20 mm TMP-Ped balloon catheter.