Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-07T08:32:37.893Z Has data issue: false hasContentIssue false

Demonstration of symcaps to measure implosion symmetry in the foot of the NIF scale 0.7 hohlraums

Published online by Cambridge University Press:  23 January 2009

A. Seifter*
Affiliation:
Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
G.A. Kyrala
Affiliation:
Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
S.R. Goldman
Affiliation:
Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
N.M. Hoffman
Affiliation:
Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
J.L. Kline
Affiliation:
Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
S.H. Batha
Affiliation:
Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
*
Address correspondence and reprint requests to: Achim Seifter, AOT-ABS, MS: H817, Los Alamos National Laboratory, Los Alamos, NM 87545. E-mail: seif@lanl.gov

Abstract

Implosions using inertial confinement fusion must be highly symmetric to achieve ignition on the National Ignition Facility. This requires precise control of the drive symmetry from the radiation incident on the ignition capsule. For indirect drive implosions, low mode residual perturbations in the drive are generated by the laser-heated hohlraum geometry. To diagnose the drive symmetry, previous experiments used simulated capsules by which the self-emission X-rays from gas in the center of the capsule during the implosion are used to infer the shape of the drive. However, those experiments used hohlraum radiation temperatures higher than 200 eV (Hauer et al., 1995; Murphy et al., 1998a, 1998b) with small NOVA scale hohlraums under which conditions the symcaps produced large X-ray signals. At the foot of the NIF ignition pulse, where controlling the symmetry has been shown to be crucial for obtaining a symmetric implosion (Clark et al., 2008), the radiation drive is much smaller, reducing the X-ray emission from the imploded capsule. For the first time, the feasibility of using symcaps to diagnose the radiation drive for low radiation temperatures, <120 eV and large 0.7 linear scales NIF Rev3.1 (Haan et al., 2008) vacuum hohlraums is demonstrated. Here we used experiments at the Omega laser facility to demonstrate and develop the symcap technique for tuning the symmetry of the NIF ignition capsule in the foot of the drive pulse.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2009
Figure 0

Fig. 1. Photograph of one of the targets. One can see the LEH, the stalk to mount the hohlraum in the experimental chamber, the window with the beryllium plug and shields to block unwanted X-rays from diagnostics.

Figure 1

Fig. 2. (Color online) Sketch of the pointing of the three different cones from each side of the hohlraum. Blue, Cone 3 (59° with respect to hohlraum axis); red, cone 2 (42°); green, cone 1 (21°). F is the distance of defocusing, x is the distance where the beam intersects the axis with respect to the laser entrance hole.

Figure 2

Table 1. Pointing, focusing and irradiation of the laser beams of the three cones for shot #45797

Figure 3

Fig. 3. (Color online) Hohlraum brightness temperature as measured by DANTE shows reproducibility of the laser drive as the desired peak temperature of 118 eV was achieved.

Figure 4

Fig. 4. (Color online) Processed images of the capsule X-ray self emission of shot #45797, where the intensity for each image is normalized to its peak. The implosion occurs at t = 6.03 ns (peak X-ray emission time), the hohlraum axis is horizontal. The brightest emission is shown by the darkest colors.

Figure 5

Fig. 5. (Color online) Detailed image of the capsule implosion of shot #45797 at peak emission time, integrated over 35 ps (FWHM). The hohlraum axis is horizontal. The parameters a(0) to a(4) are the fractional amplitudes of the Legendry-fit parameters normalized to the fitted zero order amplitude (a(0); measured to be 53.7 µm) at the 30% brightness contour.