X-ray diffraction imaging for predictive metrology of crack propagation in 450-mm diameter silicon wafers

Published online by Cambridge University Press:  19 April 2013

B.K. Tanner*
Affiliation:
Department of Physics, Durham University, South Road, Durham DH1 3LE, UK
J. Wittge
Affiliation:
University of Freiburg, Kristallographie, Geowissenschaftliches Institut, Freiburg, Germany
P. Vagovič
Affiliation:
Karlsruhe Institute of Technology, Institut für Synchrotronstrahlung, Karlsruhe, Germany
T. Baumbach
Affiliation:
Karlsruhe Institute of Technology, Institut für Synchrotronstrahlung, Karlsruhe, Germany
D. Allen
Affiliation:
Dublin City University, School of Electronic Engineering, Dublin 9, Ireland
P.J. McNally
Affiliation:
Dublin City University, School of Electronic Engineering, Dublin 9, Ireland
R. Bytheway
Affiliation:
Jordan Valley Semiconductors UK Ltd, Durham DH1 1TW, UK
D. Jacques
Affiliation:
Jordan Valley Semiconductors UK Ltd, Durham DH1 1TW, UK
M.C. Fossati
Affiliation:
Department of Physics, Durham University, South Road, Durham DH1 3LE, UK
D.K. Bowen
Affiliation:
Department of Physics, Durham University, South Road, Durham DH1 3LE, UK
J. Garagorri
Affiliation:
CEIT and Tecnun (University of Navarra), 20018 San Sebastián, Spain
M.R. Elizalde
Affiliation:
CEIT and Tecnun (University of Navarra), 20018 San Sebastián, Spain
A.N. Danilewsky
Affiliation:
University of Freiburg, Kristallographie, Geowissenschaftliches Institut, Freiburg, Germany
*
a)Author to whom correspondence should be addressed. Electronic mail: b.k.tanner@dur.ac.uk

Abstract

The apparatus for X-ray diffraction imaging (XRDI) of 450-mm wafers, is now placed at the ANKA synchrotron radiation source in Karlsruhe, is described in the context of the drive to inspect wafers for plastic deformation or mechanical damage. It is shown that full wafer maps at high resolution can be expected to take a few hours to record. However, we show from experiments on 200-, 300-, and 450-mm wafers that a perimeter-scan on a 450-mm wafer, to pick up edge damage and edge-originated slip sources, can be achieved in just over 10 min. Experiments at the Diamond Light Source, on wafers still in their cassettes, suggest that clean-room conditions may not be necessary for such characterization. We conclude that scaling up of the 300-mm format Jordan Valley tools, together with the existing facility at ANKA, provides satisfactory capability for future XRDI analysis of 450-mm wafers.

Information

Type
Technical Articles
Copyright
Copyright © International Centre for Diffraction Data 2013 
Figure 0

Figure 1. Principle of large area transmission topography at a synchrotron radiation source.

Figure 1

Figure 2. 300-mm wafer mounted in the goniometer and 500-mm translation stage.

Figure 2

Figure 3. 500-mm stage and 300-mm wafer holder with wafer mounted. Inset: 450-mm wafer holder.

Figure 3

Figure 4. Metrology of 200-mm Si wafer ex situ at room temperature after 60 s plateau annealing at 1000 °C. Slip bands originate from the notch and laser written number.

Figure 4

Figure 5. 200-mm wafer in its cassette mounted for white radiation XRDI at the Diamond Light Source. Note the radiation damage to the cassette as indicated by the red circle.

Figure 5

Figure 6. BedeScan™ transmission XRD Image of 200-mm plateau annealed Si wafer at 1000 °C for 30 s showing slip bands developing from the edge. Scan time 0.3 h.

Figure 6

Figure 7. BedeScan™ transmission XRD Image of 200-mm (001) Si wafer which had been indented at 90, 180, and 270° with respect to the notch at the bottom of the image. The small crack circled on the right side is not visible optically.

Figure 7

Table I. Process time for complete wafer mapping at Topo-Tomo beamline, ANKA, ($0\bar 22$) reflection, transmission mode, and in the laboratory on Jordan Valley BedeScan™, QCRT™, and QCTT™ instruments.