Penumbra Indigo® system to safely remove intracardiac thrombus in a 7-month-old infant with severe immunodeficiency disorder

Published online by Cambridge University Press:  28 October 2024

Raymond N. Haddad*
Affiliation:
Centre de Référence Malformations Cardiaques Congénitales Complexes—M3C, Assistance Publique—Hôpitaux de Paris, Hôpital Universitaire Necker-Enfants Malades, Paris, France
Ahmed Adel Hassan
Affiliation:
Department of Pediatric Cardiology, Heart Centre of Excellence, Al Jalila Children’s Speciality Hospital, Dubai, United Arab Emirates
Mahmoud Al Soufi
Affiliation:
Department of Pediatric Cardiology, Heart Centre of Excellence, Al Jalila Children’s Speciality Hospital, Dubai, United Arab Emirates
Mohamed Kasem
Affiliation:
Department of Pediatric Cardiology, Heart Centre of Excellence, Al Jalila Children’s Speciality Hospital, Dubai, United Arab Emirates
*
Corresponding author: Raymond N. Haddad; Email: raymondhaddad@live.com
Rights & Permissions [Opens in a new window]

Abstract

We report on a 7-month-old boy (4.2 kg/60 cm) with severe immunodeficiency disorder and bacterial septicaemia who was referred for an infected atrial thrombus secondary to a jugular central line. The echocardiogram showed a teardrop-shaped thrombus with a wide base adherent to the interatrial wall and a flimsy tail moving freely in the right atrium. Chest CT scan showed multiple lesions in both lungs consistent with infected micro-thrombi. The thrombus increased in size despite 2 weeks of antibiotics and anticoagulation. We applied the Indigo® Lightning® 7 aspiration system from Penumbra® (Alameda, USA) and removed percutaneously the thrombus under transoesophageal ultrasound and biplane fluoroscopic guidance. At 6 weeks of follow-up, the patient is alive, under enoxaparin with no procedure-related complication.

Information

Type
Brief Report
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. (a) Modified four cavities subcostal ultrasound view showing the atrial thrombus adherent to the interatrial wall with a flimsy tail across the tricuspid valve (white arrow). Note the smaller thrombus fixed to the mitral valve apparatus (blue arrow). (b) Postoperative transthoracic ultrasound showing complete atrial thrombus removal.

Figure 1

Figure 2. Illustration of components of the Pneumbra’s Indigo Lightning peripheral mechanical thrombectomy system. (a) Lightning® 7 aspiration catheter (black arrow) and SeparatorTM 7 (grey arrow). (b) Penumbra ENGINE® aspiration source and Lightning aspiration tubing.

Supplementary material: File

Haddad et al. supplementary material 1

Haddad et al. supplementary material
Download Haddad et al. supplementary material 1(File)
File 10.7 KB
Supplementary material: File

Haddad et al. supplementary material 2

Haddad et al. supplementary material
Download Haddad et al. supplementary material 2(File)
File 6.1 MB
Supplementary material: File

Haddad et al. supplementary material 3

Haddad et al. supplementary material
Download Haddad et al. supplementary material 3(File)
File 3.9 MB