Hostname: page-component-7b7567c8c-jswmv Total loading time: 0 Render date: 2026-11-15T19:53:22.058Z Has data issue: false hasContentIssue false

Effects of Prandtl number in quasi-two-dimensional Rayleigh–Bénard convection

Published online by Cambridge University Press:  16 March 2021

Xiao-Ming Li
Affiliation:
Center for Complex Flows and Soft Matter Research, and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, PR ChinaGuangdong Provincial Key Laboratory of Turbulence Research and Applications, Southern University of Science and Technology, Shenzhen 518055, PR China
Ji-Dong He
Affiliation:
Center for Complex Flows and Soft Matter Research, and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, PR China
Ye Tian
Affiliation:
Center for Complex Flows and Soft Matter Research, and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, PR ChinaGuangdong Provincial Key Laboratory of Turbulence Research and Applications, Southern University of Science and Technology, Shenzhen 518055, PR China
Peng Hao
Affiliation:
Center for Complex Flows and Soft Matter Research, and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, PR China
Shi-Di Huang*
Affiliation:
Center for Complex Flows and Soft Matter Research, and Department of Mechanics and Aerospace Engineering, Southern University of Science and Technology, Shenzhen 518055, PR China
*
†Email address for correspondence: huangsd@sustech.edu.cn

Abstract

We report an experimental study of the Prandtl-number effects in quasi-two-dimensional (quasi-2-D) Rayleigh–Bénard convection. The experiments were conducted in four rectangular convection cells over the Prandtl-number range of $11.7 \leqslant Pr \leqslant 650.7$ and over the Rayleigh-number range of $6.0\times 10^8 \leqslant Ra \leqslant 3.0\times 10^{10}$. Flow visualization reveals that, as $Pr$ increases from 11.7 to 145.7, thermal plumes pass through the central region much less frequently and their self-organized large-scale motion is more confined along the periphery of the convection cell. The large-scale flow is found to break down for higher $Pr$, resulting in a regime transition in the Reynolds number $Re$. For the $Pr$ range with a large-scale flow of system size, the $Re$ number, Nusselt number $Nu$ and local temperature fluctuations were investigated systematically. It is found that $Re$ scales as $Re \sim Ra^{0.58}Pr^{-0.82}$ in the present geometry, which suggests that it is in line with the behaviour in the 2-D configuration. On the other hand, the measured $Nu(Ra, Pr)$ relation $Nu \sim Ra^{0.289}Pr^{-0.02}$ tends to be compatible with the finding in a three-dimensional (3-D) system. For the temperature fluctuations in the cell centre and near the sidewall, they exhibit distinct $Ra$-dependent scalings that could not be accounted for with existing theories, but their $Pr$ dependences for $Pr \lesssim 50$ are in agreement with the predictions by Grossmann & Lohse (Phys. Fluids, vol. 16, 2004, pp. 4462–4472). These results enrich our understanding of quasi-2-D thermal convection, and its similarities and differences compared to 2-D and 3-D systems.

Information

Type
JFM Papers
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Table 1.Geometrical information on the convection cells for different $Pr$ numbers and the corresponding $Ra$ number ranges. Here, H (cm), L (cm) and W (cm) are the height, length and width of the convection cell, respectively. The fluid properties of the silicone oils used in the present study are also provided, where $\alpha$ ($\textrm {{K}}^{-1}$), $\kappa$ ($\textrm {{m}}^{2}\ \textrm {{s}}^{-1}$) and $\nu$ ($\textrm {{m}}^{2}\ \textrm {{s}}^{-1}$) are the thermal expansion coefficient, the thermal diffusivity and the kinematic viscosity, respectively.

Figure 1

Figure 1.(a) Schematic diagram of the experimental set-up. Here $T_1$, $T_2$ and $T_3$ indicate three small thermistors used to measure local temperature in the flow. (b) The correlation function between the signals measured by $T_2$ and $T_3$, based on which we can obtain the characteristic flow velocity. See text for the explanation. Inset: A segment of the temperature time series measured by $T_2$ and $T_3$ at $Ra \simeq 5.9\times 10^9$ and $Pr = 49.3$.

Figure 2

Figure 2.Shadowgraph images of the flow pattern at $Ra \simeq 3.6 \times 10^{9}$ for different $Pr$: (a) $Pr = 11.7$, (b) $Pr = 20.5$, (c) $Pr = 81.6$, (d) $Pr = 145.7$, (e) $Pr = 345.2$ and (f) $Pr = 650.7$. See also Movie 1 in the supplementary movies available at https://doi.org/10.1017/jfm.2021.21.

Figure 3

Figure 3.Shadowgraph images of the flow pattern at $Ra \simeq 2.1\times 10^{10}$ for (a) $Pr = 11.7$, (b) $Pr = 20.5$, (c) $Pr = 81.6$ and (d) $Pr = 145.7$. Shadowgraph images of the flow pattern for (e) $Ra =1.4\times 10^{10}$, $Pr = 345.2$ and (f) $Ra= 5.0\times 10^{9}$, $Pr = 650.7$. See also Movie 2 in the supplementary movies available at https://doi.org/10.1017/jfm.2021.21.

Figure 4

Figure 4.Log–log plots of (a) $Re$ versus $Ra$ for different $Pr$ and (b) $Re$ versus $Pr$ for different $Ra$, as indicated by the symbols. For clarity, the data in panel (b) have been shifted by multiplication by different constant factors for different $Ra$. The solid lines represent power-law fits to individual datasets. See tables 2 and 3 in the appendix for the fitting results in detail.

Figure 5

Table 2.The power-law fitting results for $Re = C_{1}Ra^{\alpha }$, $Nu= C_{2}Ra^{\gamma }$, ($\sigma _c/\Delta T$)$^{\ast } = C_{3}Ra^{\zeta }$ and ($\sigma _s/\Delta T$)$^{\ast } = C_{4}Ra^{\xi }$ at different $Pr$.

Figure 6

Table 3.The power-law fitting results for $Re = C_{5}Pr^{\beta }$ and $Nu = C_{6}Pr^{\delta }$ at different $Ra$.

Figure 7

Figure 5.(a) Plot of $Re\,f_{Re}(Pr)$ as a function of $Ra$. Here, $f_{Re}(Pr)$ is a factor used to multiply the measured $Re$ data such that the obtained results $Re \, f_{Re}(Pr)$ at different $Pr$ collapse onto a single line. Note that the factor $f_{Re}(Pr)$ depends on $Pr$ only and thus it is a constant for the dataset at each $Pr$. The solid line is the best power-law fit to all the data points: $Re \,f_{Re}(Pr) = 0.006Ra^{0.58\pm 0.01}$. (b) Plot of $ReRa^{-0.58}$ as a function of $Pr$. The data are mean values of $ReRa^{-0.58}$ averaged over all the $Ra$ numbers for each $Pr$. The solid line represents a power-law fit: $ReRa^{-0.58} = 0.074Pr^{-0.82\pm 0.04}$.

Figure 8

Figure 6.Plots of (a) $U/V_{f}$ and (b) ($U/V_{f})Pr^{0.5}$ as functions of $Pr$. Here, $U$ is the characteristic velocity as explained in § 2 and $V_{f}$ is the free-fall velocity. The dashed line in panel (a) shows the best-fitting exponent if a power-law fit is attempted to all the data points therein.

Figure 9

Figure 7.Plots of $Nu$ as a function of (a) $Ra$ for different $Pr$ and (b) $Pr$ for different $Ra$, as indicated by the symbols. For clarity, the data in panel (a) have been shifted by multiplication by the different constant factors shown for different $Pr$. The solid lines represent power-law fits to individual datasets with the fitting results shown in tables 2 and 3.

Figure 10

Figure 8.(a) Plot of $Nu\,f_{Nu}(Pr)$ as a function of $Ra$. Here, $f_{Nu}(Pr)$ is a factor used to multiply the measured $Nu$ data such that the obtained results $Nu\,f_{Nu}(Pr)$ at different $Pr$ collapse onto a single line. Note that the factor $f_{Nu}(Pr)$ depends on $Pr$ only and thus it is a constant for the dataset at each $Pr$. The solid line is the best power-law fit to all the data points except for the open symbols: $Nu\,f_{Nu}(Pr)$ = $0.16Ra^{0.289\pm 0.002}$. (b) Plot of $Nu$ compensated by $Ra^{0.289}$ as a function of $Pr$. The data are the mean values of $Nu Ra^{-0.289}$ averaged over different $Ra$ at each $Pr$. The solid line is a power-law fit: $NuRa^{-0.289} = 0.17Pr^{-0.02\pm 0.01}$.

Figure 11

Figure 9.(a) The measured $Nu$ compared with the values predicted by the updated GL model (Stevens et al.2013). The dashed lines indicate the updated GL model predictions multiplied by 0.93, 0.93, 0.94, 0.94, 0.95, 0.96, 0.96 and 0.98 from highest to lowest $Ra$, respectively. (b) The relative difference in $Nu$ between the present study and the GL model prediction, i.e. $(Nu - Nu_{GL})/Nu_{GL}$.

Figure 12

Figure 10.The p.d.f.s of temperature fluctuation measured in the central region of the convection cell for different $Pr$: (a) $Ra\simeq 3.6\times 10^{9}$ and (b) $Ra\simeq 2.1\times 10^{10}$.

Figure 13

Figure 11.(a) Normalized temperature fluctuation $\sigma _{c}/\Delta T$ at the cell centre as a function of $Ra$ for different $Pr$. (b) Plot of $\sigma _{c}/\Delta T$ for $Pr = 20.5$ measured at two convection cells. See text for detailed explanation. (c) Plot of $(\sigma _{c}/\Delta T)^{\ast }$ versus $Ra$ as indicated by the same symbols as used in panel (a). Here, $(\sigma _{c}/\Delta T)^{\ast } = (\sigma _{c}/\Delta T)/(H/12.6)^{0.4}$ represents temperature fluctuation with the system size effect compensated. The solid lines are power-law fits to individual datasets with the fitting results listed in table 2. (d) Plot of $(\sigma _{c}/\Delta T)^{\ast }$ versus $Pr$ for different $Ra$. The two dashed lines represent the predictions for interior temperature fluctuation by two different models. See text for explanation.

Figure 14

Figure 12.The p.d.f.s of temperature fluctuation measured near the sidewall of the convection cell for different $Pr$: (a) $Ra\simeq 3.6\times 10^{9}$ and (b) $Ra\simeq 2.1\times 10^{10}$.

Figure 15

Figure 13.(a) Normalized temperature fluctuation $\sigma _{s}/\Delta T$ near the sidewall region as a function of $Ra$ for different $Pr$. (b) Plot of $\sigma _{s}/\Delta T$ versus $Ra$ for $Pr = 20.5$ measured at two convection cells. The symbols share the same meanings as in figure 11(b). (c) Plot of $(\sigma _{s}/\Delta T)^{\ast }$ versus $Ra$ for different $Pr$ as indicated by the same symbols as used in panel (a). Here, $(\sigma _{s}/\Delta T)^{\ast } = (\sigma _{s}/\Delta T)/(H/12.6)^{-0.55}$ represents temperature fluctuation with the system size effect compensated. The solid lines are power-law fits with the fitting results shown in table 2. (d) Plot of $(\sigma _{s}/\Delta T)^{\ast }$ versus $Pr$ for different $Ra$. The dashed line represents the prediction by Grossmann & Lohse (2004) for temperature fluctuation close to the sidewall.

Figure 16

Table 4.Experimental parameters ($Pr, Ra$) and the measured results ($Re, Nu$) for all the measurements in the present study. The positions of the two thermistors $T_2$ and $T_3$, i.e. their distance away from the sidewall relative to the cell's length $s/L$, are also provided.

Li et al. supplementary movie 1

See pdf file for movie caption

Download Li et al. supplementary movie 1(Video)
Video 49.8 MB

Li et al. supplementary movie 2

See pdf file for movie caption

Download Li et al. supplementary movie 2(Video)
Video 50.9 MB
Supplementary material: PDF

Li et al. supplementary material

Captions for movies 1-2

Download Li et al. supplementary material(PDF)
PDF 14.4 KB