Hostname: page-component-74656f9884-skzmx Total loading time: 0 Render date: 2026-11-06T03:58:38.041Z Has data issue: false hasContentIssue false

Reducing Herbicide Particle Drift: Effect of Hooded Sprayer and Spray Quality

Published online by Cambridge University Press:  21 November 2018

Henry C. Foster
Affiliation:
Graduate Student, Department of Plant and Soil Sciences, Mississippi State University, Mississippi State, MS, USA
Benjamin P. Sperry
Affiliation:
Graduate Student, Department of Plant and Soil Sciences, Mississippi State University, Mississippi State, MS, USA
Daniel B. Reynolds*
Affiliation:
Professor and Endowed Chair, Department of Plant and Soil Sciences, Mississippi State University, Mississippi State, MS, USA
Greg R. Kruger
Affiliation:
Associate Professor and Extension Specialist, University of Nebraska, North Platte, NE, USA
Steve Claussen
Affiliation:
President of Willmar Fabrications LLC, Willmar, MN, USA
*
Author for correspondence: Daniel B. Reynolds, Professor and Endowed Chair, Department of Plant and Soil Sciences, Mississippi State University, 32 Creelman Street, Mississippi State, MS 39762. (E-mail: dreynolds@pss.msstate.edu)
Rights & Permissions [Opens in a new window]

Abstract

A field study was conducted in 2015 and 2016 to compare particle drift of glyphosate using a fluorescent tracer dye applied with hooded and open sprayers at four spray qualities (Fine [F], Medium [M], Very-Coarse [VC], and Ultra-Coarse [UC]). F and M spray qualities exhibited up to 86% and 56% less drift, respectively, out to 31 m downwind with the hooded sprayer than with the open sprayer. Conversely, VC and UC spray qualities were not affected by sprayer type out to 31 m downwind. From 43 to 104 m downwind, hooded sprayer applications exhibited approximately 50% less drift than open sprayer applications, regardless of spray quality. From 43 to 89 m downwind, F spray qualities, regardless of sprayer type, exhibited higher drift than all other spray qualities. These data indicate that hooded sprayers considerably reduce drift of all spray qualities at short distances downwind. Additionally, at longer distances downwind, both larger spray qualities and sprayer hoods reduced drift independently.

Information

Type
Research Article
Copyright
© Weed Science Society of America, 2018. 
Figure 0

Figure 1 Broadcast Redball hooded sprayer with a continuous shield (top) and broadcast Redball open sprayer (bottom) (Wilmar Manufacturing LLC, Benson, MN).

Figure 1

Table 1 Application parameters for treatments investigating the effect of sprayer type and spray quality on particle drift.

Figure 2

Table 2 Meteorological conditions during applications comparing particle drift from Nebraska (NE) and Mississippi (MS) field trials.a,b

Figure 3

Figure 2 Nonlinear asymptotic regression modela fitted over data from the current study, which investigated the effect of spray quality and sprayer type on particle drift. aRegression model Y=Yasym[1–exp(–aI/Yasym)], where Y is the response variable (% relative fluorescence [RFU]), Yasym is the Y asymptote, I is the explanatory variable (distance from the boom), and a is the initial slope at low I values.

Figure 4

Table 3 Particle drift deposition of fluorescent tracer dye from 2 to 31 m downwind as influenced by spray quality and sprayer type.a

Figure 5

Table 4 Particle drift deposition of fluorescent tracer dye from 42 to 104 m downwind influenced by sprayer type averaged across four spray qualities.a,b

Figure 6

Table 5 Particle drift deposition of fluorescent tracer dye from 43 to 104 m downwind as influenced by spray quality averaged across hooded and open sprayer types.a

Figure 7

Table 6 Regression modela parameters from analysis of the effect of sprayer type and spray quality on particle drift.b