Hostname: page-component-7b7567c8c-jswmv Total loading time: 0 Render date: 2026-11-15T16:28:31.241Z Has data issue: false hasContentIssue false

Experimental evidence of velocity profile inversion in developing laminar flow using magnetic resonance velocimetry

Published online by Cambridge University Press:  25 July 2018

A. Reci
Affiliation:
Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge CB3 0AS, UK
A. J. Sederman*
Affiliation:
Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge CB3 0AS, UK
L. F. Gladden
Affiliation:
Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge CB3 0AS, UK
*
†Email address for correspondence: ajs40@cam.ac.uk

Abstract

A discrepancy exists between the predictions of analytical solutions of approximate Navier–Stokes equations and numerical finite-difference solutions of the full Navier–Stokes equations regarding the development of laminar flow at the entrance to cylindrical pipes for Newtonian fluids. Starting from a uniform velocity profile at the entrance to the pipe, analytical solutions of approximate Navier–Stokes equations predict the velocity profile to have a maximum at the centre of the pipe at all times. In contrast, numerical finite-difference solutions of the full Navier–Stokes equations have suggested that the location of the velocity maximum moves from the wall towards the centre of the pipe at a short distance from the entrance, after which it remains at the centre of the pipe. This study presents the first experimental evidence of the moving velocity maximum from the wall towards the centre of the pipe. The initial uniform velocity profile was achieved by flowing the fluid through a monolith composed of narrow parallel channels and the flow development was investigated using magnetic resonance velocimetry. The experimentally observed variation of the position and size of the velocity maximum with the Reynolds number and the distance from the entrance to the pipe is shown to be in good agreement with the predictions of numerical finite-difference solutions of the full Navier–Stokes equations.

Information

Type
JFM Papers
Copyright
© 2018 Cambridge University Press 
Figure 0

Figure 1.Schematic of the development of the axial velocity profile at the entrance to a cylindrical pipe for laminar flow, as predicted by (a) analytical solutions of approximate Navier–Stokes equations and by (b) numerical finite-difference solutions of the full Navier–Stokes equations.

Figure 1

Figure 2.(a) Schematic of the positions inside the monolith (position A) and at the exit of the monolith, or equivalently the entrance to the pipe ($z/D=0.25$, 0.5, 1, 2, 4, 6) where MR velocimetry acquisitions of the axial velocity in a transverse plane were obtained. (b) MR velocimetry pulse sequence used in this work, with the important acquisition parameters identified. Flow is in the positive $z$-direction.

Figure 2

Figure 3.(a) Cross-section magnitude image of the fluid in the monolith, composed of parallel square channels, at a distance of 10 mm before the exit of the monolith (position A in figure 2a). The fluid is MR-active while the monolith is MR-inactive and does not contribute to the MR signal. The image comprises of $512\times 512$ pixels and is of resolution $0.039~\text{mm}\times 0.039~\text{mm}$. The thickness of the wall separating the channels is approximately 0.15 mm. (b) Axial velocity image of a single representative channel highlighted in (a) at $Re_{p}=500$, $Re_{c}=21$. The image comprises of $16\times 16$ pixels and is of resolution $0.039~\text{mm}\times 0.039~\text{mm}$. The maximum uncertainty in the pixel-wise reported velocity is $1.4~\text{mm}~\text{s}^{-1}$. The axial velocity in the monolith is denoted by $v$ in order to distinguish it from the axial velocity at the exit of the monolith, denoted by $u$.

Figure 3

Figure 4.Radially averaged axial velocity profile at a position of 10 mm before the exit of the monolith (position A in figure 2a) at the four Reynolds numbers studied. $r$ refers to the radial distance; $R$ refers to the radius of the pipe; and $u_{mean}$ refers to the mean velocity. The lines are included to guide the eye. The graphs were constructed by radial averaging the mean velocities of the fluid within each channel. The uncertainty related to each data point is dominated by the circular asymmetry of the velocity profile, rather than the uncertainty related to pixel-wise velocity measurements. The maximum uncertainty of the reported $u/u_{mean}$ values is 0.05. For reasons of clarity, error bars are not shown.

Figure 4

Figure 5.Radially averaged axial velocity profiles at positions $z/D=0.25$, 0.5, 1, 2, 4 and 6 from the entrance to the pipe and Reynolds numbers, $Re_{p}$, of (a) 120, (b) 250, (c) 500 and (d) 1100. The lines are included to guide the eye. For each Reynolds number, the entrance length required for fully developed laminar flow, $z_{ent}/D$, is included in the figure. The uncertainty related to each data point is dominated by the circular asymmetry of the velocity profile, rather than the uncertainty related to pixel-wise velocity measurements. The maximum uncertainty of the reported $u/u_{mean}$ values is 0.03. For reasons of clarity, error bars are not shown.

Figure 5

Figure 6.Comparison of the present experimental results with the results from finite-difference numerical methods solution of the full Navier–Stokes equations from Friedmann et al. (1968) and Dombrowski et al. (1993) at $Re_{p}=500$ and Wagner (1975) at $Re_{p}=400$. The graphs show the variation of (a) the critical radius $r_{c}/R$ at which the maximum of the velocity occurs, (b) the maximum of the velocity $u_{max}/u_{mean}$ and (c) the velocity at the centre of the pipe $u_{centre}/u_{mean}$ with the distance from the entrance to the pipe $z/D$. The results are only shown for values of $z/D$ at which the maximum in the velocity profile is not at the centre of the pipe. The uncertainty associated with the estimation of $r_{c}/R$ is dominated by the spatial resolution of the MR image; the uncertainty associated with $u_{max}/u_{mean}$ and $u_{centre}/u_{mean}$ is dominated by the circular asymmetry of the velocity profile, rather than the uncertainty related to pixel-wise velocity measurements.