Hostname: page-component-7b7567c8c-2n9c9 Total loading time: 0 Render date: 2026-11-17T02:09:30.555Z Has data issue: false hasContentIssue false

Turbulent drag reduction over air-fed hydrophobic surfaces with longitudinal grooves

Published online by Cambridge University Press:  21 July 2025

Shijie Qin
Affiliation:
College of Energy Engineering, Zhejiang University, Hangzhou 310027, PR ChinaState Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, PR China
Shuai Sun
Affiliation:
China Ship Development and Design Center, Wuhan 430064, PR China
Shuze Tang
Affiliation:
College of Energy Engineering, Zhejiang University, Hangzhou 310027, PR China
Zonglong Wang
Affiliation:
Marine Design and Research Institute of China, Shanghai 200011, PR China
Dazhuan Wu*
Affiliation:
College of Energy Engineering, Zhejiang University, Hangzhou 310027, PR ChinaState Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, PR China
*
Corresponding author: Dazhuan Wu, wudazhuan@zju.edu.cn

Abstract

This study presents an experimental investigation on the drag reduction (DR) over air-fed hydrophobic surfaces (AFHS) with longitudinal grooves in a turbulent boundary layer (TBL). The AFHS, designed with longitudinal grooves and air supplement channels, enables active maintenance and reversible restoration of the plastron in TBL. The shear stress sensor, particle image velocimetry (PIV) and interfacial visualization are applied for simultaneous measurement of the skin friction drag, TBL velocity profiles and plastron coverage. The AFHS demonstrated the ability to control plastron shape and enhance its sustainability with friction Reynolds numbers up to 1723. Drag reductions ranging from 14.8–35.8 % are obtained over the AFHS. At same designed air fraction, the AFHS exhibits higher DR than the conventional hydrophobic surface. By minimizing influences of the degradation of plastron coverage and the shape, the monotonic increase in DR and slip velocity with Reynolds number is confirmed, which corroborates trends from direct numerical simulations. Turbulence statistics measured by PIV reveal an apparent decrease in near-wall viscous shear stress, and corresponding slip velocities both in the viscous sublayer and log-law region. The Reynolds shear stress and streamwise velocity fluctuations over the AFHS are larger than those over a smooth wall, where near-wall vortex cores of the AFHS are found to be shifted 10 % towards the wall. This study presents the first simultaneous experimental quantification of skin friction, plastron coverage and turbulence statistics under sustained plastron conditions in TBL. The results demonstrate the efficacy of the plastron control strategy on hydrophobic surfaces and address a critical gap in validating numerical predictions for turbulent flows in practical applications.

Information

Type
JFM Papers
Copyright
© The Author(s), 2025. Published by Cambridge University Press
Figure 0

Figure 1.Schematic of (a) conventional HS and (b) AFHS with longitudinal grooves.

Figure 1

Figure 2.(a) The picture of the AFHS and (b) the 3-D microscopic morphology of the grooves measured by the light scanning interferometry. The nominal dimensions of the AFHS as well as the HSs are 50 mm in width and 100 mm in length.

Figure 2

Table 1.Dimensions and contact angles of the tested samples. Within the tested turbulent Reynolds numbers, the wall unit ($l_{v}$) varies from 13.23 to 8.02 μm and the corresponding normalized structural pitch (W+) ranges from 9.07 to 14.96.

Figure 3

Figure 3.Schematics of (a) the water tunnel and measurement systems, (b) the test section of the water tunnel, the assembled shear stress sensor and the tested sample. The dimensions of the water tunnel rectangular test section are 1.0 m × 0.12 m × 0.18 m (length, height and width) and the operating speed of the tunnel is adjustable between 0–3.5 m s−1. The tested sample, embedded in the assembled shear stress sensor, is mounted on the ceiling of the test section, with a distance of 682.5 mm between the turbulence generator and the centre of the sample.

Figure 4

Figure 4.(a) Schematic and (b) photograph of the assembled shear stress sensor and the tested sample for skin friction drag measurement. The sensor comprises a mounting base, air chamber, spring element, optical encoder and optical scale. The tested sample is mounted on the sensor, aligned flush with the front and rear walls, while maintaining a 50 μm gap around it to ensure proper isolation and minimize interference.

Figure 5

Figure 5.Calibration of shear stress sensor for skin friction drag measurement. (a) The comparison between the measured skin friction drags and the semiempirical equation (Schlichting & Gersten 2016). (b) The comparison of the measured skin friction coefficient against theoretical predictions across different Reynolds numbers. The calibration process involved repeated measurements of skin friction drag over a smooth plate under different incoming flow velocities.

Figure 6

Figure 6.(a) Schematic and (b) actual set-up of the macroscopic and microscopic interfacial visualization systems. For macroscopic visualization, a collimated light source and a SLR camera (Nikon D7500, denoted as Camera 1 in the image) are utilized to quantitatively characterize the overall plastron coverage. This was achieved by measuring the reflection contrast between the air–water interface and the solid wall. A high resolution Grasshopper3 camera (Flir, GS3-U3-51S5M) is integrated with a 45° reflector and a Cassegrain optical telescope system (Seika, Maksutov–Cassegrain system) to capture the fine details of the plastron’s shape.

Figure 7

Figure 7.The overall and local views of the plastron captured by the macroscopic and microscopic interfacial reflection systems. (a) The flat plastron on the microgroove appears shiny in the macroscopic image but exhibits a dark groove in the microscopic image. (b) The concave plastron demonstrate a dark macroscopic image which reveals a bright reflective region on the right side of the groove in the microscopic image. (c) The convex plastron shows a dark macroscopic image but displays a bright reflective region on the left side of the groove in the microscopic image.

Figure 8

Figure 8.(a) The planar PIV system for the TBL velocity profile measurement. A high-frequency Nd-YAG Laser (CNI, AO-X-532, 532 nm) and a high-resolution CCD camera (ImperX, ICL-B3340, 3312 × 2488 pixels, 5.5 μm pixel–1) equipped with a microlens (Nikon, Micro-Nikkor 60 mm f/2.8G ED) are employed. (b) The velocity contour measured by the planar PIV system at ReL = 1.85 × 106.

Figure 9

Figure 9.Calibration of PIV measurement. (a) The normalized mean velocity profiles, and (b) the streamwise and wall-normal velocity fluctuations of the smooth surface. The classical law of the wall is shown for comparison and the results of Ling et al. (2016) measured by the in-line digital holographic microscopy at similar friction Reynolds numbers are also included.

Figure 10

Figure 10.Control of plastron shape on the AFHS by pressure regulation. From (a) to (e), with ΔP gradually increases from negative to positive, the plastron shape changes from concave to convex, i.e. in the region marked by two red dashed lines, a reflective shiny band shifts from one side to another side. The notations R and L indicate the right and left side of the groove. The $\theta$ and $h$ are the tangential angle and penetration height of the plastron estimated by the Young–Laplace equation, respectively.

Figure 11

Figure 11.The comparison of microscopic interfacial images between HS (a)–(e) and AFHS ( f)–(j) under different ReL. Notations ‘R’ and ‘L’ indicate the right and left side of the groove. The red dashed line pairs are added for comparison of the reflective intensity.

Figure 12

Figure 12.Comparison of macroscopic plastron images of (a) HS and (b) AFHS across a range of ReL. The flow direction is from the top to the bottom. The bright region indicates that the tested sample is covered with a layer of plastron, and the dark region indicates the deterioration or depletion of the plastron.

Figure 13

Figure 13.Comparison of the calculated plastron coverage (φ) between HS and AFHS at different ReL. The overall coverage of the plastron is quantitively extracted from the macroscopic plastron images by image processing and extraction methods.

Figure 14

Figure 14.Time traces of skin-friction drag measured by the shear stress sensor over the smooth plate, the conventional HS and the AFHS at ReL = 2.17 × 106.

Figure 15

Figure 15.(a) The DR of the HS and AFHS at same designed air fraction (φgroove = 0.4) under different ReL. The HS (H = 130 μm) is the conventional hydrophobic surface, the AFHS (H = 130 μm) and AFHS-H (H = 180 μm) are the AFHS. (b) The DR of AFHS at the same groove depth but different designed air fraction (AFHS, φgroove = 0.4; AFHS-D1, φgroove = 0.3; AFHS-D2, ϕgroove = 0.2).

Figure 16

Figure 16.The DR normalized by the plastron coverage (φ) versus the ReL. The fitted line is obtained by the least square fitting method based on data from different HSs tests.

Figure 17

Figure 17.(a) Mean velocity profiles (b) viscous shear stress and Reynolds shear stress at ReL = 1.85 × 106 in TBL flow for the smooth wall and the AFHS, respectively. The velocities are scaled by their own inner units, while the viscous and Reynolds shear stress are scaled by the total wall stress of the smooth wall for the quantitative comparison of shear stresses.

Figure 18

Figure 18.Comparison of velocity fluctuations between the smooth wall and the AFHS in (a) streamwise direction, and (b) wall-normal direction at ReL = 1.85 × 106. Results are scaled by the smooth wall inner units.

Figure 19

Figure 19.The comparison of time-averaged local swirling strength contours of (a) the smooth wall and (b) the AFHS at ReL = 1.85 × 106. The local swirling strength (Zhou et al.1999), $\skew2\bar{\lambda}_{ci}$, is applied to visualize the near-wall vortical structures by extracting the imaginary part of the complex eigenvalue of the velocity gradient tensor. The x+and y+ are the normalized streamwise and wall-normal distance.

Figure 20

Figure 20.(a) The wall-normal profile of the streamwise averaged swirling strength, $\skew2\bar{\lambda}_{ci}$ for the smooth wall and the AFHS at ReL = 1.85 × 106. (b) The comparison of wall-normal $\skew2\bar{\lambda}_{ci}$ profiles of the smooth wall and the AFHS at different ReL.

Figure 21

Figure 21.(a) Mean velocity profiles of the AFHS at different ReL. The classical law of the wall is shown for comparison. (b) The normalized mean slip velocity, $\bar{u}_s^{+}$, at different ReL. The slip velocity is extracted from the mean velocity profile in the linear viscous sublayer measured by the planar PIV.

Figure 22

Figure 22.Magnitude of DR versus the normalized slip velocity both measured in this experiment and those in the literature. Drag reduction is measured by the in-house made shear stress sensor and the normalized slip velocity is extracted from PIV data for varying Reτ = 885–1723. The experimental results by Ling et al. (2016)and Abu Rowin & Ghaemi (2020), and the DNS results by Martell et al. (2010), Park et al. (2013), Lee et al. (2015) and Rastegari & Akhavan (2019) are also shown. The theoretical prediction (lines) on the basis of Fukagata, Kasagi & Koumoutsakos (2006) and Busse & Sandham (2012) are included for comparison, where the λx and λz indicate components of the so-called slip lengths in streamwise and spanwise directions, respectively.