Hostname: page-component-6898cfcb55-w5hgh Total loading time: 0 Render date: 2026-11-11T20:23:26.091Z Has data issue: false hasContentIssue false

Comparative quantification of varicella-zoster virus in air, pharyngeal swabs, and vesicle content in patients with varicella, disseminated zoster, and localized herpes zoster

Published online by Cambridge University Press:  15 November 2024

Kei Yamamoto*
Affiliation:
Diseases Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan
Maki Nagashima
Affiliation:
Diseases Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan
Motoko Ishida
Affiliation:
Diseases Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan
Masayuki Ota
Affiliation:
Diseases Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan
Yuichi Katanami
Affiliation:
Diseases Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan
Ryoko Adachi
Affiliation:
Department of Pharmacy, National Center for Global Health and Medicine, Tokyo, Japan
Ayako Shigeno
Affiliation:
Department of Pharmacy, National Center for Global Health and Medicine, Tokyo, Japan
Takeshi Tamaki
Affiliation:
Department of Dermatology, National Center for Global Health and Medicine, Tokyo, Japan
Norio Ohmagari
Affiliation:
Diseases Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan
*
Corresponding author: Kei Yamamoto; Email: kyamamoto@hosp.ncgm.go.jp
Rights & Permissions [Opens in a new window]

Abstract

We evaluated the viral load of varicella-zoster virus (VZV) in ambient air, vesicle, and pharyngeal swabs in VZV-infected patients. Of 46 cases, 6 had VZV detected in indoor air samples from patient rooms. Results suggest an association between viral load in the pharyngeal swab and indoor air.

Information

Type
Concise Communication
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Table 1.Characteristics of study patients

Figure 1

Figure 1.ROC curve demonstrating the varicella-zoster viral load of pharyngeal secretions used to detect the varicella-zoster virus in the air inside the room. AUC 0.89 (95% CI 0.78–0.99). Youden’s index showed a cutoff value of 2.9 log10 copies/test with a sensitivity of 0.78 and a specificity of 1.00. ROC, receiver operating characteristic.

Supplementary material: File

Yamamoto et al. supplementary material

Yamamoto et al. supplementary material
Download Yamamoto et al. supplementary material(File)
File 909.4 KB