Hostname: page-component-74656f9884-rngvg Total loading time: 0 Render date: 2026-11-04T17:30:12.883Z Has data issue: false hasContentIssue false

Compliance modeling of a full 6-DOF series–parallel flexure-based Stewart platform-like micromanipulator

Published online by Cambridge University Press:  22 March 2022

Suraj Kumar Mishra*
Affiliation:
Robotics and Intelligent Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, India
Cheruvu Siva Kumar
Affiliation:
Robotics and Intelligent Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, India
*
Rights & Permissions [Opens in a new window]

Abstract

With many micromanipulator designs emerging in micro and nanosystem applications, the element of compliance in the mechanisms is gaining attention. Several designs consider motions limited in a plane for high accuracy and repeatability as needed in micro/nano manipulation applications. Extending this to a full spatial configuration with coupled motions of series and parallel linkages with flexure joints of 1-degree-of-freedom (DOF) and 3-DOF needs a systematic analytical approach. One such approach for compliance analysis is presented in this article for a mechanism designed at Indian Institute of Technology Kharagpur. To validate the analytical models, finite element analysis simulations are performed with the help of the Abaqus-6.14 software package. Following the successful validation, the effect of structural parameters on the performance is presented with the help of the analytical expressions. We explore the performance of the mechanism with different dimensions of flexures of a particular type. Results indicate that the design with dissimilar dimensional parameters can give superior performance.

Information

Type
Research Article
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Figure 1. A flexure member subjected to a general force vector at its free end.

Figure 1

Figure 2. Schematic diagram of a generalized compliant parallel manipulator.

Figure 2

Figure 3. Schematic diagram of the modified CPM for input compliance determination.

Figure 3

Figure 4. Schematic diagram for amplification ratio determination.

Figure 4

Figure 5. Design elements of the micromanipulator.

Figure 5

Figure 6. Kinematic diagram of a limb of the mechanism.

Figure 6

Figure 7. A limb of the micromanipulator with dimensions.

Figure 7

Figure 8. The general Stewart platform and compliant version of the micromanipulator.

Figure 8

Figure 9. Output compliance, input compliance, and amplification ratio.

Figure 9

Figure 10. Coordinate system assignment scheme for compliant members.

Figure 10

Figure 11. Numbering of key nodes and points in the limb-1 of the mechanism.

Figure 11

Figure 12. Connectivity graph of members in a limb for output compliance determination.

Figure 12

Figure 13. Amplification ratio formulation.

Figure 13

Figure 14. Connectivity graph of members for calculation of $C_A^G$.

Figure 14

Figure 15. Simplified connectivity graph of steps involved in calculation of $C_{D(2-6)}$.

Figure 15

Figure 16. Simplified connectivity graph of members for calculation of input compliance.

Figure 16

Table I. Dimensional and simulation parameters.

Figure 17

Figure 17. FEA model of the CPM.

Figure 18

Figure 18. Input and output compliance determination using FEA simulations.

Figure 19

Table II. Comparison of results obtained from analytical and FEA model.

Figure 20

Figure 19. Effect of flexure dimensions on compliance.

Figure 21

Figure 20. Effect of flexure and beam parameters on AR.

Figure 22

Figure 21. Effect of dissimilar flexures.

Figure 23

Figure 22. Stretching of a thin flexure.