Hostname: page-component-7b7567c8c-7pwfn Total loading time: 0 Render date: 2026-11-16T06:12:14.649Z Has data issue: false hasContentIssue false

Wall-bounded thermal turbulent convection driven by heat-releasing point particles

Published online by Cambridge University Press:  15 December 2022

Yuhang Du
Affiliation:
State Key Laboratory for Turbulence and Complex Systems, and Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing 100871, PR ChinaJoint Laboratory of Marine Hydrodynamics and Ocean Engineering, Pilot National Laboratory for Marine Science and Technology (Qingdao), Shandong 266299, PR China
Yantao Yang*
Affiliation:
State Key Laboratory for Turbulence and Complex Systems, and Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing 100871, PR ChinaJoint Laboratory of Marine Hydrodynamics and Ocean Engineering, Pilot National Laboratory for Marine Science and Technology (Qingdao), Shandong 266299, PR China
*
†Email address for correspondence: yantao.yang@pku.edu.cn

Abstract

In this work we investigate the thermal convection driven by heat-releasing point particles. Three-dimensional direct numerical simulations are conducted for $1\times 10^7\le {\textit {Ra}} \le 1\times 10^{10}$ and $0.01\le {\textit {St}} \le 10$, where the Rayleigh number ${\textit {Ra}}$ and Stokes number ${\textit {St}}$ measure the strengths of the heat releasing rate and the Stokes drag, respectively. A regime at intermediate Stokes numbers is identified with most particles accumulating into the top boundary layer region, while for other cases particles are constantly advected over the entire domain. For the latter state, the flow motions are stronger at the upper part of the domain. The thicknesses of both momentum and thermal boundary layers at the top plate follow the same scaling law with ${\textit {Ra}}$ and show minor dependences on ${\textit {St}}$. The volume-averaged temperature and convective flux exhibit non-monotonic variations as ${\textit {St}}$ increases and reach their minimums at intermediate ${\textit {St}}$. The fraction coefficient of heat flux, i.e. the ratio between the heat flux through the bottom plate and the total flux through both plates, shares the similar dependence on ${\textit {St}}$ as the convective flux. The relation between these scaling laws can be explained by using the global balance between the dissipation and convective flux. The scaling laws for the transition between different flow regimes are also proposed and agree with the numerical results. The preferential concentration of particles is observed for all cases and is strongest at intermediate Stokes numbers, for which multiscale clustering emerges with small clusters forming larger ones.

Information

Type
JFM Papers
Copyright
© The Author(s), 2022. Published by Cambridge University Press
Figure 0

Figure 1.The explored phase space in the ${\textit {St}}$–${\textit {Ra}}$ plane. The black diamonds mark the cases in which all the particles gradually accumulate near the top plates and simulation cannot continue. All other cases can reach a statistically steady state. For those marked by orange squares the normalized number density of particles exceeds $10$ in the upper viscous boundary layer (BL), while for those marked by red circles are not. The grey dashed line marks the scaling of $St^{u}_{cr}$ with slope $-5/3$, and the grey dash-dotted line for $St^{l}_{cr}$ with slope $-5$.

Figure 1

Figure 2.Mean profiles for the cases with ${\textit {Ra}}=10^{10}$ and different ${\textit {St}}$. (a) The r.m.s. of vertical velocity. (b) The r.m.s. of horizontal velocity. (c) The horizontally averaged temperature. (d) The standard deviation of temperature ($\theta _{std}$).

Figure 2

Figure 3.The thickness of (a) top viscous BL, (b) bottom viscous BL. The dashed lines in both panels have the same slope of $-0.196$. The value of the slope is obtained through linear regression with the details given in the main text.

Figure 3

Figure 4.The thickness of (a) top thermal BL, (b) bottom thermal BL and (c) single thermal BL versus Rayleigh number. The dashed lines in the three panels have the same slope of $-0.196$.

Figure 4

Figure 5.The dependences of (a) volume-averaged temperature $\langle \theta \rangle _V$ and (b) volume-averaged convective flux $\langle w\theta \rangle _V$ on the Stokes number ${\textit {St}}$ and Rayleigh number ${\textit {Ra}}$. (c,d) The ${\textit {Ra}}$-compensated plots of the same dataset.

Figure 5

Figure 6.The variations of the fraction coefficient $F_B$ and its two components versus the control parameters: (a) increasing ${\textit {St}}$ for fixed ${\textit {Ra}}=10^{10}$; (b,c) increasing ${\textit {Ra}}$ for fixed ${\textit {St}}=0.01$ and ${\textit {St}}=10$, respectively.

Figure 6

Figure 7.(a) The dependence of fraction coefficient $F_B$ on the Stokes number ${\textit {St}}$ and Rayleigh number ${\textit {Ra}}$. (b) The ${\textit {Ra}}$-compensated plot of the same dataset.

Figure 7

Figure 8.The mean profiles of the viscous dissipation rate $\langle \epsilon _u\rangle _h$ versus the height $z$ for different ${\textit {St}}$ and fixed ${\textit {Ra}}=10^{10}$.

Figure 8

Figure 9.The total dissipation rate in (a) the top BL region, (b) the bottom BL region and (c) the bulk versus the Reynolds number, respectively. In panels (a–c) the slope of the dashed line is $2.4$, $2.33$ and $2.7$, respectively.

Figure 9

Figure 10.The temporally averaged flow field on a vertical midplane. Contours show the vertical velocity, and the streamlines are integrated with the in-plane velocity vector. Here (a) ${\textit {St}}=0.01$, (b) ${\textit {St}}=0.4$, and (c) ${\textit {St}}=10$, respectively, and the Rayleigh number is ${\textit {Ra}}=10^{10}$.

Figure 10

Figure 11.The compensated plot of Reynolds number ${\textit {Re}}$ versus ${\textit {Ra}}$.

Figure 11

Figure 12.The time evolution of the profile of mean number density of particles for two cases with (a) $St=0.1$ and (b) $St=0.02$, respectively. The Rayleigh number ${\textit {Ra}}=10^9$ is same for the two cases.

Figure 12

Figure 13.(a–c) The contours of vertical velocity on a middle vertical plane, and (d–f) the contours of temperature field along with the instantaneous particle distribution on the same vertical plane, respectively. Here (a,d), (b,e) and (c,f) are ${\textit {St}}=0.01$, $0.4$ and $10$, respectively. The Rayleigh number is ${\textit {Ra}}=10^{10}$.

Figure 13

Figure 14.(a) The probability density function of the vertical positions of particles. (b) The Stokes number ${\textit {St}}_\eta$ defined by the local Kolmogorov time scale versus the height. For all the shown cases ${\textit {Ra}}=10^{10}$.

Figure 14

Figure 15.Typical snapshots of the horizontal distribution of particles and their Voronoï diagram for $Ra=10^{10}$ and different ${\textit {St}}$: (a–c) ${\textit {St}}=0.01$; (d–f) ${\textit {St}}=0.4$; (g–h) ${\textit {St}}=10$. Here (a,d,g), (b,e,h) and (c,f,i) are $z=\lambda _{u,bot}, 0.5H, H-\lambda _{u,top}$, respectively.

Figure 15

Figure 16.The p.d.f.s of normalized Voronoï area $A/\langle A \rangle _p$ in the horizontal planes for different ${\textit {St}}$ and ${\textit {Ra}}=10^{10}$: (a) $z=\lambda _{u,bot}$; (b) $z=0.5H$; (c) $z=H-\lambda _{u,top}$.

Figure 16

Figure 17.The p.d.f.s of normalized Voronoï area $A/\langle A \rangle _p$ in the horizontal planes for different ${\textit {St}}$ and ${\textit {Ra}}$: (a,d) $z=\lambda _{u,bot}$; (b,e) $z=0.5H$; (c,f) $z=H-\lambda _{u,top}$. Here panels (a–c) are for ${\textit {St}}=0.01$, and (d–f) for ${\textit {St}}=10$, respectively.

Figure 17

Figure 18.The RDFs in the horizontal planes for different ${\textit {St}}$ and fixed ${\textit {Ra}}=10^{10}$: (a) $z=\lambda _{u,bot}$; (b) $z=0.5H$; (c) $z=H-\lambda _{u,top}$.

Figure 18

Table 1.Summary of the numerical simulations. Columns from left to right are the Rayleigh number, the Stokes number, the resolutions in the horizontal and vertical directions, the fraction of internally heat across bottom boundaries, the Reynolds number based on the r.m.s. value of velocity, the mean system temperature, the thickness of top and bottom viscous BL, the thickness of temperature BL, the mean concentration $c_s$ for the top BL, the mean temperature difference of two phases, the non-dimensional total heat flux across top and bottom plates $Nu$, respectively. The resolution in the $y$ direction is the same as that in the $x$ direction. For all cases the aspect ratio of the domain $L=4$, the Prandtl number $Pr=0.7$, the non-dimensional particle number density $C=1\times 10^5$, the heat-capacity ratio $\varPhi _{\theta }=0.1$ and the heat-mixing parameter $\sigma =1$.