Experimental investigations of X-pinch backlighters on QiangGuang-1 generator

Published online by Cambridge University Press:  22 March 2011

J. Wu
Affiliation:
Department of Engineering Physics, Tsinghua University, Beijing, China Northwest Institute of Nuclear Technology, Xi'anChina
L. Wang
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
A. Qiu*
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
J. Han
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
M. Li
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
T. Lei
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
P. Cong
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
M. Qiu
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
H. Yang
Affiliation:
Northwest Institute of Nuclear Technology, Xi'anChina
M. Lv
Affiliation:
Department of Engineering Physics, Tsinghua University, Beijing, China
*
Address correspondence and reprint requests to: Aici Qiu, Northwest Institute of Nuclear Technology, Xi'an 710024, China. E-mail: qiuac@cae.cn

Abstract

Experiments of the return current post installed X-pinches were carried out on the 1-MA “QiangGuang-1” facility with the purpose of understanding X-pinch characteristics under this setup and establishing X-pinch backlighting diagnostics for the wire-array Z-pinches. Different wire-array loads along with the two-wire 30 µm Mo X-pinch backlighter were tested. The X-pinches emit the X-ray radiation with the burst time variation of ± 4 ns and the bright spot size of  ~30 µm. X-ray backlighting shadowgraphy images of the over-mass and radiation-suppressed Z-pinch wire array were obtained.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2011
Figure 0

Fig. 1. Photo of the one frame X-pinch-based X-ray backlighting configuration.

Figure 1

Table 1. Summary of the X-pinch backlighters with the main-loads tested in the experiments

Figure 2

Fig. 2. (Color online) (a) Transmission of the filters and wires. The Mo L-shell line radiation is in 2–3 keV X-ray energy range. (b) The dependence of the Kodak biomax-MS X-ray film's optical density on photon exposure for different energies.

Figure 3

Fig. 3. (Color online) The main load current and the detector signals from shot 10095 (8 × 50 µm W CWA with 2 × 30 µm Mo X-pinch) (a) and shot 10100 (8 × 20 µm Al PWA with 2 × 30 µm Mo X-pinch) (b). X-pinch radiations were recorded by the PCD and the wire-array load by the XRD.

Figure 4

Fig. 4. The first X-ray burst timing of the return current-post based X-pinches. X-ray signals from shot 10092 and 10097 were missed.

Figure 5

Fig. 5. (a) The X-ray backlighting image of the slit array from shot 10095 (8 × 50 µm W CWA with 2 × 30 µm Mo X-pinch). (b) A lineout through the center of the backlighting image. (c) An expanded plot of the left slit image from (b). Vertical bars indicates the distance between the 12.5% and 87.5% peak intensity points.

Figure 6

Fig. 6. (a) X-pinch backlighting (2 × 30 µm Mo X-pinch) arrangement for the 8-wire-50 µm W CWA Z-pinch from shot 10097. (b) Backlighting images from shot 10097.

Figure 7

Fig. 7. (a) X-pinch backlighting (2 × 30 µm Mo X-pinch) arrangement for the 12-wire-50 µm Al CWA Z-pinch from shot 10098. (b) Backlighting images from shot 10098. (c) An expanded region of the W-5 in (b).