Room shielding with frequency-selective surfaces for electromagnetic health application

Published online by Cambridge University Press:  16 February 2016

Soheil Hashemi*
Affiliation:
Department of Electrical Engineering, Iran University of Science and Technology (IUST), Narmak, Tehran, Iran Bioelectromagnetics Laboratory, Iran University of Science and Technology (IUST), Narmak, Tehran, Iran
Ali Abdolali
Affiliation:
Department of Electrical Engineering, Iran University of Science and Technology (IUST), Narmak, Tehran, Iran Bioelectromagnetics Laboratory, Iran University of Science and Technology (IUST), Narmak, Tehran, Iran
*
Corresponding author: S. Hashemi Email: s_hashemy@iust.ac.ir
Rights & Permissions [Opens in a new window]

Abstract

Use of frequency-selective surfaces (FSSs) is proposed to shield rooms against electromagnetic fields in order to achieve secure indoor communications and reduce human exposure to external fields. The secure room is designed using two-layer FSSs with an FR4 substrate to cover 10–12 GHz frequency band. Different elements in each layer and shift in the position of elements are the reasons for more than 3 GHz bandwidths in X band. The performance of the structure is also stable versus the misaligned position of layers. An equivalent circuit model is proposed for the structure and results show −20 dB isolation between inside and outside of the room in the desired frequency band. Bio tissue is located inside the cubic structure with FSS walls and the results of the specific absorption rate are demonstrated and compared in two rooms with FSS cover on concrete walls and a room with concrete walls. The 17 × 17 cm2 two-layer FSS is fabricated for the measurement and the results are presented. The designed FSS can be used in the construction of wave-isolated room for any application.

Information

Type
Research Papers
Copyright
Copyright © Cambridge University Press and the European Microwave Association 2016 
Figure 0

Fig. 1. Design geometries in (a) first layer, (b) second layer, and (c) both layers.

Figure 1

Fig. 2. (a) Geometry of periodic structure from the front and side views. (b) Bandstop filter response.

Figure 2

Fig. 3. Equivalent circuit of the design.

Figure 3

Table 1. Elements of the circuit model.

Figure 4

Fig. 4. Cubic FSS structure as the equivalent model of a room.

Figure 5

Fig. 5. SE of periodic FSS for both TE and TM polarizations.

Figure 6

Fig. 6. Frequency response of the proposed circuit model and full-wave analysis.

Figure 7

Fig. 7. Percentage of shifts at resonant frequencies versus misaignment.

Figure 8

Fig. 8. Plane wave radiation to biologic tissue. (a) A room with 3 cm concrete walls. (b) Inside room with FSS cover on 3 cm concrete walls.

Figure 9

Fig. 9. Vertical cut plane of the equivalent phantom of finger. (1) Bone with the radius of 5.5 mm, (2) muscle with 2.5 mm width, (3) fat with 2 mm width, and (4) skin with 2 mm width.

Figure 10

Fig. 10. SAR values inside the tissue at 10, 11, and 12 GHz. (a) Inside a room with 3 cm concrete walls at 8 GHz, (b) inside FSS structure at 8 GHz, (c) inside a room with 3 cm concrete walls at 10 GHz, (d) inside FSS structure at 10 GHz, (e) inside a room with 3 cm concrete walls at 12 GHz, and (f) inside FSS structure at 12 GHz.

Figure 11

Fig. 11. Measurement. (a) setup and (b) fabricated plate.

Figure 12

Fig. 12. S21or shielding efficiency parameter of measurement.