Hostname: page-component-6898cfcb55-zsp5v Total loading time: 0 Render date: 2026-11-11T10:54:23.964Z Has data issue: false hasContentIssue false

Inactivation and/or physical removal of Candida auris from floors by detergent cleaner, disinfectants, microfiber, and ultraviolet C light (UV-C)

Published online by Cambridge University Press:  02 October 2023

William A. Rutala*
Affiliation:
Statewide Program for Infection Control and Epidemiology, University of North Carolina School (UNC) of Medicine, Chapel Hill, North CarolinaDivision of Infectious Diseases, UNC School of Medicine, Chapel Hill, North Carolina
Austin C. Bolomey
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Jennifer L. Cadnum
Affiliation:
Research Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio
Curtis J. Donskey
Affiliation:
Geriatric Research, Education and Clinical Center, Louis Stokes Cleveland Veterans’ Affairs Medical Center, Cleveland, OhioDepartment of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio
*
Author for correspondence: William A. Rutala, PhD, MPH, CIC, Division of Infectious Diseases, UNC School of Medicine, Bioinformatics Building, CB#7030, 130 Mason Farm Road, Chapel Hill, NC 27514-7030. Email: brutala@med.unc.edu
Rights & Permissions [Opens in a new window]

Abstract

Contaminated surfaces may be a source of transmission for the globally emerging pathogen, Candida auris. Because floors may be a source of C. auris contamination on hands, strategies for inactivating or removing C. auris from floors were investigated. A sporicidal disinfectant and UV-C were most effective in inactivating C. auris on floors.

Information

Type
Concise Communication
Copyright
© The Author(s), 2023. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Figure 1.Picture of 30×30-cm (12×12-inch) floor tiles used for inoculation with Candida auris and wiping with microfiber and cotton cloth mops. Three 30×30-cm (12×12-inch) tiles were inoculated (shown as 1–3) and wiped from left to right and back 3 times.

Figure 1

Table 1.Inactivation and/or Removal of C. auris From Floors by UV-C and Microfiber or Cloth Mops With Water, Detergent