Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-06T22:17:40.371Z Has data issue: false hasContentIssue false

Impact of CT-based planning and bladder volume changes on the dosimetry of vaginal vault brachytherapy

Published online by Cambridge University Press:  09 February 2021

Jeyaanth Venkatasai*
Affiliation:
Department of Radiation Oncology, Dr Ida B Scudder Cancer Centre, Christian Medical College, Vellore, India
Jebakarunya Ramireddy
Affiliation:
Department of Radiation Oncology, Dr Ida B Scudder Cancer Centre, Christian Medical College, Vellore, India
Arvind Sathyamurthy
Affiliation:
Department of Radiation Oncology, Dr Ida B Scudder Cancer Centre, Christian Medical College, Vellore, India
Henry Finlay Godson
Affiliation:
Department of Radiation Oncology, Dr Ida B Scudder Cancer Centre, Christian Medical College, Vellore, India
Reka Karuppusami
Affiliation:
Department of Biostatistics, Christian Medical College, Vellore, India
Saikat Das
Affiliation:
Department of Radiation Oncology, Dr Ida B Scudder Cancer Centre, Christian Medical College, Vellore, India Department of Radiation Oncology, AIIMS, Bhopal, India
Thomas Samuel Ram
Affiliation:
Department of Radiation Oncology, Dr Ida B Scudder Cancer Centre, Christian Medical College, Vellore, India
*
Author for correspondence: Dr Jeyaanth Venkatasai, Department of Radiation Oncology, Dr Ida B Scudder Cancer Center, Christian Medical College, Vellore, Tamil Nadu 632004, India. Tel: +91-9444275245/0416-228-3145. E-mail: jeyaanth@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Aim:

To compare dose to target and organs at risk (OARs) in conventional plan (2D) versus computed tomography (CT)-based three-dimensional (3D) plan in vaginal cuff brachytherapy (VBT) and to compare the effect of bladder distension on target and OARs dosimetry.

Materials and methods:

Post-hysterectomy patients with an indication for VBT were included in the study. All patients underwent planning CT scans with a full bladder and an empty bladder protocol. For each CT, two plans were generated—one library-based 2D plan and another CT-based 3D plan. Dosimetric parameters were recorded for clinical target volume (CTV) and OARs.

Results:

A total of 92 observations were made from data collected from 46 patients. Difference between CTV dose in terms of 2D and 3D plans were not statistically significant for CTV (p = 0·11). Significant reduction in D0·1cc, D1cc and D2cc dose parameters were observed in bladder, rectum, sigmoid and bowel doses with the 3D plan (p < 0·001). Bladder distension showed a 20% reduction in dose for bowel (p < 0·001). Bladder distension also showed a 6·12% (p = 0·047) increase in D2cc, but there was a significant reduction in the mean dose to the bladder.

Conclusion:

Our study demonstrates the dosimetric benefits with 3D CT-based planning for VBT over 2D-based conventional planning and benefit of bladder distension in the reduction of bowel dose without compromising dose to the target volume.

Information

Type
Original Article
Copyright
© The Author(s), 2021. Published by Cambridge University Press
Figure 0

Table 1. Patient characteristics

Figure 1

Table 2. Dose parameters for CTV and organs at risk (OARs) in 2D (library) and 3D plans

Figure 2

Figure 1. 2D versus 3D dose–volume comparison in (a) bladder, (b) rectum, (c) sigmoid and (d) bowel.

Figure 3

Table 3. Dose parameters for CTV and OARs in full bladder and empty bladder plans

Figure 4

Figure 2. Dose (D2cc) variation in organs at risk (OARs) in full bladder state.

Figure 5

Table 4. D2cc physical dose parameters for OARs and cumulative EQD2 for EBRT and brachytherapy

Figure 6

Figure 3. Differences between empty bladder (a—axial, b—sagittal, dark blue—bladder, cyan—bowel, pink—sigmoid) and full bladder (c—axial, d—sagittal, dark blue—bladder, yellow—bowel, pink—sigmoid). Black arrows—Bladder horns.