Hostname: page-component-74656f9884-g96k6 Total loading time: 0 Render date: 2026-11-10T08:09:37.386Z Has data issue: false hasContentIssue false

Determining the extent of pressurized flow beneath Storglaciären, Sweden, using results of tracer experiments and measurements of input and output discharge

Published online by Cambridge University Press:  20 January 2017

Jack Kohler*
Affiliation:
NVE (Norwegian Water Resources and Energy Administration), Box 5091, Maj., N-0301 Osh, Norway
Rights & Permissions [Opens in a new window]

Abstract

Two experiments were conducted on the drainage system beneath the Lower part of the ablation zone of Storglaciären, a small valley glacier in northern Sweden. In the first experiment, over 70 tracer tests were performed in a cluster of moulins during a 1 month period, at sub-daily intervals. In the second experiment, input- and output-discharge signals were measured on the supraglacial melt stream emptying into a moulin and on the proglacial stream to which the moulin drains. The data from these two experiments are used in an idealized model of the subglacial drainage system to calculate the percentage of the system flowing as an open channel. Results from the tracer experiment suggest that the system is pressurized to within 60-340 m of the snout, while analysis of the discharge data indicates pressurized ronduits to within 0-415 m of the snout.

Information

Type
Research Article
Copyright
Copyright © International Glaciological Society 1995
Figure 0

Fig. 1. (a) Ablation area of Storglaciären, showing bedrock contours (gray lines, contour interval 210 m), surface contours (heavy black lines, contour interval 210 m), moulins (black circles), tracer-injection sites (labels), proglacial streams, and Sydjåkk dam (X). Equilibrium line is at about 1400 m. (b) Cross-section along profile X-X'. The black and white bars show the system lengths of ihe study area flowing as pressurized conduit and open channel, for both the tracer (T) and discharge (Q) analysis. The gray bar denotes the range of reasonable values for the pressurized-conduit length, and the tick mark shows the best fit to the data

Figure 1

Fig. 2. Discharge Q, conductivity C, and time-lo-peak tp for a typical trace

Figure 2

Fig. 3. Average discharge Q and velocity U for tracts in riegel moulins M1–M4. and in proglacial stream S2 (symbols). Dashed line is fitted to S2 data using Equation (5) for a V-notck channel

Figure 3

Table 1. Hydraulic parameter values for two open-channel models and closed conduit

Figure 4

Fig. 4. Upper graph: ratio of average discharge Q to average velocity U for the riegel moulins M1 (black squares), M2 (black triangles), M3 (crosses), and M4 (white triangles). Lower graph: smoothed discharge (dark gray line), hourly discharge (lighter gray line) and average discharge at the time of the trace for the riegel moulins (symbols). Dotted vertical lines demarcate times of tracer (T) and discharge (Q) analysis.

Figure 5

Fig. 5. Simple model diagram. See text for explanation of symbols

Figure 6

Fig. 6. Average discharge Q and velocity U for traces conducted 2–10 August (open circles), restricted best fit of data to Equation (24) (solid line), and 68.3% confidence limits (light gray lines)

Figure 7

Fig. 7. Input and output discharge Qi and Qo in a pressurized-conduit system for a step increase in Qi, and time tc at which Qo is 95% of Qi.

Figure 8

Fig. 8. Input and output discharge Qi and Qo in a combined presurized-conduit–open-channel flow system for a spike input, and the time toc it takes the pressure wave to traverse the open-channel segment of the system.

Figure 9

Fig. 9. Moulin bag: a fabric funnel is connected to a section of pipe with a hole at ike bottom and is suspended within themouth of a moulin. A pressure transducer in the pipe monitors the water level within the bag.

Figure 10

Fig. 10. Rating curve for the moulin bag in M1. Two curves art used because the moulin bag had two holes at different heights from the bottom

Figure 11

Fig. 11. Input-discharge (gray line) and output-discharge (black line) signals after normalization of the input signal. Time is relative to midnight, 5 August 1988. (b) Low-frequency component of the input-discharge (gray line) and output-discharge (black line) signals, (c) Input-discharge (gray line) and output-discharge (black line) signals with the low-frequeney components subtracted.

Figure 12

Fig. 12. Calculated transfer function, with close-up of the first 120 points (gray line) and the theoretical transfer function using best-fit values of the free parameters in Equation (48) (dashed line)