Hostname: page-component-7b7567c8c-wxvwp Total loading time: 0 Render date: 2026-11-15T15:49:48.638Z Has data issue: false hasContentIssue false

A boundary integral method with volume-changing objects for ultrasound-triggered margination of microbubbles

Published online by Cambridge University Press:  19 December 2017

Achim Guckenberger*
Affiliation:
Biofluid Simulation and Modeling, Fachbereich Physik, Universität Bayreuth, 95440 Bayreuth, Germany
Stephan Gekle
Affiliation:
Biofluid Simulation and Modeling, Fachbereich Physik, Universität Bayreuth, 95440 Bayreuth, Germany
*
†Email address for correspondence: achim.guckenberger@uni-bayreuth.de

Abstract

A variety of numerical methods exist for the study of deformable particles in dense suspensions. None of the standard tools, however, currently include volume-changing objects such as oscillating microbubbles in three-dimensional periodic domains. In the first part of this work, we develop a novel method to include such entities based on the boundary integral method. We show that the well-known boundary integral equation must be amended with two additional terms containing the volume flux through the bubble surface. We rigorously prove the existence and uniqueness of the solution. Our proof contains as a subset the simpler boundary integral equation without volume-changing objects (such as red blood cell or capsule suspensions) which is widely used but for which a formal proof in periodic domains has not been published to date. In the second part, we apply our method to study microbubbles for targeted drug delivery. The ideal drug delivery agent should stay away from the biochemically active vessel walls during circulation. However, upon reaching its target it should attain a near-wall position for efficient drug uptake. Though seemingly contradictory, we show that lipid-coated microbubbles in conjunction with a localized ultrasound pulse possess precisely these two properties. This ultrasound-triggered margination is due to hydrodynamic interactions between the red blood cells and the oscillating lipid-coated microbubbles which alternate between a soft and a stiff state. We find that the effect is very robust, existing even if the duration in the stiff state is more than three times lower than the opposing time in the soft state.

Information

Type
JFM Papers
Copyright
© 2017 Cambridge University Press 
Figure 0

Figure 1.(a) Example of a triclinic unit cell $\unicode[STIX]{x1D6E4}$ (thick lines), together with 11 replicas (thin grey lines). In this example, the two basis vectors $\boldsymbol{a}^{(1)}$ and $\boldsymbol{a}^{(2)}$ lie in the $x$–$y$-plane, but $\boldsymbol{a}^{(2)}$ is not parallel to the $y$-axis. (b) Two-dimensional sketch of the general three-dimensional problem. $\unicode[STIX]{x1D6E4}\subset \mathbb{R}^{3}$ contains the whole unit cell (everything within the dashed border $\unicode[STIX]{x2202}\unicode[STIX]{x1D6E4}$). $\unicode[STIX]{x1D6FA}\subset \unicode[STIX]{x1D6E4}$ is the ambient fluid with dynamic viscosity $\unicode[STIX]{x1D707}$ (light blue). As an example, two capsule-like entities (${\mathcal{C}}_{1}$, ${\mathcal{C}}_{2}$), two volume-changing bubbles (${\mathcal{B}}_{1}$, ${\mathcal{B}}_{2}$) and a wall ${\mathcal{W}}_{1}$ are shown. The normal vectors always point into $\unicode[STIX]{x1D6FA}$. The arrows on the left represent an imposed flow.

Figure 1

Figure 2.Simulation set-up. (a) Snapshot of the large simulation containing 30 red blood cells and two microbubbles. Periodic boundary conditions are used, i.e. the left and right non-translucent cylinders are periodic images of the centre one which has a length of $48~\unicode[STIX]{x03BC}\text{m}$ in this case. (b) Sketch of Marmottant et al.’s model for lipid-coated microbubbles (Marmottant et al.2005; Overvelde et al.2010). The effective surface tension $\unicode[STIX]{x1D6FE}$ is a function of the effective radius which varies between $R_{min}$ and $R_{max}$ during an ultrasound period. The bubble is in the soft buckled state for $R_{eff}\leqslant R_{soft}$ and in the stiff ruptured state for $R_{eff}>R_{stiff}$, as indicated by the two inset sketches.

Figure 2

Figure 3.Margination behaviour of purely soft and purely stiff non-oscillating (a) and oscillating (b) microbubbles. $\unicode[STIX]{x1D6FE}=\text{const.}$ in all cases. We depict the radial positions of the centroids of two bubbles with constant effective surface tensions in blood flow as a function of time. The surface tensions are set to $\unicode[STIX]{x1D6FE}=\unicode[STIX]{x1D6FE}_{soft}=0.5\unicode[STIX]{x1D705}_{S}$ (red/orange) and $\unicode[STIX]{x1D6FE}=\unicode[STIX]{x1D6FE}_{stiff}=10\unicode[STIX]{x1D705}_{S}$ (black/grey). For (b), bubbles oscillate with a frequency of $f=1~\text{kHz}$, leading to a variation of $R_{eff}$ between $1.7~\unicode[STIX]{x03BC}\text{m}$ and $2.075~\unicode[STIX]{x03BC}\text{m}$. Curves for different $\unicode[STIX]{x1D6FE}$ constitute independent simulations. The red blood cells, shown as light grey lines, illustrate the cell-free layer between $7~\unicode[STIX]{x03BC}\text{m}$ and the wall. The vessel radius is $11~\unicode[STIX]{x03BC}\text{m}$, the haematocrit is fixed to 16 % and the maximal flow velocity is $u_{max}\approx 4.7~\text{mm}~\text{s}^{-1}$. The soft bubbles ($\unicode[STIX]{x1D6FE}=\unicode[STIX]{x1D6FE}_{soft}$) remain in the centre, whereas the stiff bubbles ($\unicode[STIX]{x1D6FE}=\unicode[STIX]{x1D6FE}_{stiff}$) show margination.

Figure 3

Figure 4.Ultrasound-triggered margination. (a) Radial positions of the centroids of two microbubbles coated with lipids, modelled according to Marmottant et al.’s law (Marmottant et al.2005; Overvelde et al.2010). Since the ultrasound is off at the beginning, the bubbles are soft and thus remain in the vessel interior (effective radius $R_{eff}=2~\unicode[STIX]{x03BC}\text{m}$). When the oscillations are switched on at ${\approx}4~\text{s}$, ultrasound-triggered margination leads to rapid migration to the vessel wall. Here, $\unicode[STIX]{x1D6FF}=1$, i.e. the bubbles are stiff for the first half of the ultrasound period and soft during the second with their effective surface tension varying in the range $\unicode[STIX]{x1D6FE}\in [0.5;10]\unicode[STIX]{x1D705}_{S}$. The effective radii alternate between $1.7~\unicode[STIX]{x03BC}\text{m}$ and $2.23~\unicode[STIX]{x03BC}\text{m}$ in each period. See the SI for a movie. (b) Average radial positions of the oscillating bubbles and the RBCs for several different values of $\unicode[STIX]{x1D6FF}$. The rightmost point corresponds to the limit $\unicode[STIX]{x1D6FF}\rightarrow \infty$ (i.e. always stiff) from figure 3(b). Error bars are determined as explained in the main text and the SI.

Figure 4

Figure 5.Average asphericities of oscillating lipid-coated microbubbles. (a) The left figure shows the result for a single microbubble in an infinite shear flow with shear rate $s=544~\text{s}^{-1}$ as a function of $\unicode[STIX]{x1D6FF}$. At $\unicode[STIX]{x1D6FF}\approx 0.05$ the deformation increases sharply while for $\unicode[STIX]{x1D6FF}>0.1$ almost no deformation is seen. The limiting value $\unicode[STIX]{x1D6FF}\rightarrow \infty$ is shown as a red solid line at the bottom. The surface tension varies in $\unicode[STIX]{x1D6FE}\in [0.5;10]\unicode[STIX]{x1D705}_{S}$ and the oscillation frequency is $f=1~\text{kHz}$. Error bars indicate the minimal and maximal asphericities during one ultrasound period. The two inset snapshots show the bubbles with their maximal deformation for $\unicode[STIX]{x1D6FF}=0.032$ (left inset) and $\unicode[STIX]{x1D6FF}=1$ (right inset). (b) Asphericity of the bubbles from figure 4(a) averaged over consecutive time intervals of 0.5 s.

Figure 5

Figure 6.Polar plot of several bubble trajectories (i.e. as viewed from the outlet). The figure shows the $\unicode[STIX]{x1D6FF}=0.74$ and $\unicode[STIX]{x1D6FF}=1$ simulations used for figure 4(b), representing different system realizations. Trajectories only shown for $t>1~\text{s}$ or after definite margination. Rare short-lived migration events to the inside occur. Each bubble in each simulation is shown in a different colour. The outer grey dashed line depicts the vessel radius.

Figure 6

Figure 7.Influence of frequency: behaviour of two oscillating lipid-coated microbubbles for $\unicode[STIX]{x1D6FF}=1$ and a haematocrit of 16 %, once for a frequency of $f=1~\text{kHz}$ and once for 10 kHz (two distinct simulations); $u_{max}\approx 4.7~\text{mm}~\text{s}^{-1}$. (a) Radial positions of the centroids. The red blood cells are shown in light grey. (b) Corresponding microbubble asphericities averaged over consecutive time intervals of 50 ms.

Figure 7

Figure 8.Influence of haematocrit: (a) only bubbles ($\text{haematocrit}=0$); (b) average radial position for $\unicode[STIX]{x1D6FF}=1$ as a function of haematocrit. Values and error bars extracted from several simulations as in figure 4(b).

Figure 8

Figure 9.Influence of the velocity for $\unicode[STIX]{x1D6FF}=1$ and a haematocrit of 16 %: average radial position as a function of the flow velocity. Values and error bars extracted from several simulations as in figure 4(b).

Figure 9

Figure 10.Overlapping of objects with the unit cell boundary $\unicode[STIX]{x2202}\unicode[STIX]{x1D6E4}=\unicode[STIX]{x2202}\widetilde{\unicode[STIX]{x1D6E4}}\cup a^{\prime }\cup b^{\prime }$. Primed quantities lie outside of the unit cell (except $a^{\prime }$ and $b^{\prime }$ which form portions of $\unicode[STIX]{x2202}\unicode[STIX]{x1D6E4}$). A single object $O_{B}^{\prime }\cup O_{A}$ is shown. This object has a periodic image $O_{B}\cup O_{A}^{\prime }$. Furthermore, both are cut at the same place into two parts as they overlap with $\unicode[STIX]{x2202}\unicode[STIX]{x1D6E4}$. The four closed sets are $O_{B}^{\prime }$, $O_{A}$, $O_{B}$ and $O_{A}^{\prime }$. The corresponding surfaces without the cut faces are $B^{\prime }$, $A$, $B$ and $A^{\prime }$. For the left object, the cut faces (dotted) are $a$ and $b^{\prime }$, where both lie on $\unicode[STIX]{x2202}\unicode[STIX]{x1D6E4}$ and are identical except that their normal vectors point in opposite directions; i.e. there is no gap between $a$ and $b^{\prime }$. Similar for its right image (but with $b$ and $a^{\prime }$). Moreover, there is no real gap between $\unicode[STIX]{x2202}\widetilde{\unicode[STIX]{x1D6E4}}$ and the objects. $\unicode[STIX]{x2202}\unicode[STIX]{x1D6FA}$ in this figure is given by $\unicode[STIX]{x2202}\unicode[STIX]{x1D6FA}=\unicode[STIX]{x2202}\widetilde{\unicode[STIX]{x1D6E4}}\cup A\cup B$; in the general case $\unicode[STIX]{x2202}\unicode[STIX]{x1D6FA}$ also contains the full surfaces of objects completely located within the unit cell.

Guckenberger and Gekle supplementary movie

Video showing an excerpt from the simulation depicted in fig. 4 (a) in the main text. The ultrasound is switched on at around 4s.

Download Guckenberger and Gekle supplementary movie(Video)
Video 198.3 MB
Supplementary material: PDF

Guckenberger and Gekle supplementary material

Supplementary Information

Download Guckenberger and Gekle supplementary material(PDF)
PDF 4.2 MB