Parallel rotation for negating Coriolis force effect on heat transfer

Published online by Cambridge University Press:  31 January 2020

A. Sarja
Affiliation:
Department of Mechanical and Aerospace Engineering North Carolina State University Raleigh, NCUSA
P. Singh*
Affiliation:
Department of Mechanical Engineering Mississippi State University Mississippi State, MSUSA
S.V. Ekkad
Affiliation:
Department of Mechanical and Aerospace Engineering North Carolina State University Raleigh, NCUSA
Rights & Permissions [Opens in a new window]

Abstract

Gas turbine blades feature multi-pass internal cooling channels, through which relatively colder air bled from the compressor is routed to cool internal walls. Under rotation, due to the influence of Coriolis force and centrifugal buoyancy, heat transfer at the trailing side enhances and that at the leading side reduces, for a radially outward flow. This non-uniform temperature distribution results in increased thermal stress, which is detrimental to blade life. In this study, a rotation configuration is presented which can negate the Coriolis force effect on heat and fluid flow, thereby maintaining uniform heat transfer on leading and trailing walls. A straight, smooth duct of unit aspect ratio is considered to demonstrate the concept and understand the fluid flow within the channel and its interaction with the walls. The new design is compared against the conventional rotation design. Numerical simulations under steady-state condition were carried out at a Reynolds number of 25000, where the Rotation numbers were varied as 0, 0.1, 0.15, 0.2, 0.25. Realisable version of k-$\varepsilon$ model was used for turbulence modelling. It was observed that new rotation (parallel) configuration’s heat transfer on leading and trailing sides were near similar, and trailing side was marginally higher compared to leading side. An interesting phenomenon of secondary Coriolis effect is reported which accounts for the minor differences in heat transfer augmentation between leading and trailing walls. Due to centrifugal buoyancy, the fluid is pushed towards the radially outward wall, resulting in a counter-rotating vortex pair, which also enhances the heat transfer on leading and trailing walls when compared to stationary case.

Information

Type
Research Article
Copyright
© Royal Aeronautical Society 2020
Figure 0

Figure 1. Representation of orthogonal and parallel rotation configurations (not drawn to scale).

Figure 1

Figure 2. Hexahedral mesh (a) On the walls (b) At a cross section of the channel (flow into the plane).

Figure 2

Figure 3. Global averaged normalised Nusselt number variation with grid size.

Figure 3

Table 1 Test matrix

Figure 4

Figure 4. Normalized Nusselt number $$(Nu/N{u_0})$$ contours in the last $${\rm{25}}{d_h}$$ region for orthogonal mode rotation at Re = 25000, Ro = 0.25 for constant flux wall condition $${(x/{D_h} = {\rm{25}}\;to\;{\rm{50}}}$$).

Figure 5

Figure 5. Normalized Nusselt number contours $$(Nu/N{u_{\bf{0}}})$$ in the last 25 dh region for parallel mode rotation at Re = 25000, Ro = 0.25 for constant flux wall condition (from x/d = 25 Dh to 50 Dh).

Figure 6

Figure 6. Span wise averaged normalized Nusselt number $$(Nu/N{u_{\bf{0}}})$$ distribution at Re = 25000, Ro = 0.25, for constant flux wall heating condition for (a) orthogonal rotation (b) parallel rotation.

Figure 7

Figure 7. Secondary Coriolis force on the planes normal to bulk flow at various axial locations.

Figure 8

Figure 8. Comparison of leading and trailing wall normalised Nusselt numbers for all Rotation numbers with constant flux case for (a) Orthogonal mode rotation (b) Parallel mode rotation.

Figure 9

Figure 9. Variation of Span-wise averaged normalised Nusselt number along axial location parallel mode rotation on (a) Trailing wall (b) Leading wall (c) Top wall (d) Bottom wall with constant flux heating condition.

Figure 10

Figure 10. Variation of global averaged normalised Nusselt number in the last 25 dh with Rotation number for parallel mode rotation (a) constant flux wall heating condition (b) Constant temperature wall heating condition.

Figure 11

Figure 11. Secondary flow due to centrifugal buoyancy and normalised bulk fluid temperatures on the planes normal to bulk flow at various axial locations (a) constant heat flux (b) constant wall temperature.

Figure 12

Figure 12. Normalised turbulent kinetic energy contours in the last 25 dh region for orthogonal mode rotation at Re = 25000, Ro = 0.25 for constant flux wall condition (from x/d = 25 Dh to 50 Dh).

Figure 13

Figure 13. Normalised turbulent kinetic energy contours in the last 25 dh region for parallel mode rotation at Re = 25000, Ro = 0.25 for constant flux wall condition (from x/d = 25 Dh to 50 Dh).

Figure 14

Figure 14. Comparison of normalised Nusselt number between constant flux and constant temperature conditions at Rotation numbers (a) Ro 0.1 (b) Ro 0.15 (c) Ro 0.2 (d) Ro 0.25.

Figure 15

Figure 15. Comparison of buoyancy number between constant flux and constant temperature conditions, Ro = 0.25.