Hostname: page-component-7b7567c8c-2rsb6 Total loading time: 0 Render date: 2026-11-12T05:53:06.096Z Has data issue: false hasContentIssue false

Icing on a Non-Rotating Cylinder Under Conditions of High Liquid Water Content in the Air: II. Heat Transfer and Rate of Ice Growth

Published online by Cambridge University Press:  20 January 2017

Jouko Launiainen
Affiliation:
Department of Geophysics, University of Helsinki, Fabianinkatu 24 A, SF-00100 Helsinki 10, Finland
Markku Lyyra
Affiliation:
Institute of Marine Research, Box 33, SF-00931 Helsinki, Finland
Rights & Permissions [Opens in a new window]

Abstract

The rate of ice growth and heat transfer during a stationary wet-growth icing was studied, based on wind-tunnel experiments of Reynolds numbers of I04 to 105, and air temperatures of 0°C to –13°C. The convective heat-transfer coefficient, a quantity of primary importance entering the heat-balance equation of a freezing surface, was found to depend strongly on the liquid water content in the air (or rather, on the impinging water flow on the surface). The convective heat-transfer coefficient was considered theoretically and the dependence is thought to be caused by an increase in the surface roughness and, especially, by an effect of the impinging water droplets on viscous sub-layers and on turbulent heat transfer near the icing boundary. The above evaluation allows us to calculate an accretion efficiency for each icing condition.

Résumé

Résumé

La vitesse de croissance de la glace et les transferts de chaleur pendant un givrage humide stationnaire sont étudiés dans une soufflerie pour des nombres de Reynolds de 104 à 105 et des températures de 0°C à –13°C. On a trouvé que le coefficient de transfert convectif de la chaleur, paramétre essentiel de l’équation régissant le bilan thermique d’une surface en train de geler, dépendait fortement de la teneur en eau liquide de l’air (ou plutôt du flux de gouttelettes liquides heurtant la surface). Le coefficient de transfert convectif de la chaleur est étudié d’un point de vue théorique. On pense que ses variations sont liées à une augmentation de la rugosité de la surface et, surtout, aux conséquences de l’impact des gouttelettes d’eau sur les sous couches visqueuses et sur les transferts turbulents de chaleur près du front de congélation. Les estimations précédentes nous permettent de calculer l’efficacité de l’accrétion de glace pour chaque condition de givrage.

Zusammenfassung

Zusammenfassung

Auf der Grundlage von Windkanal-Versuchen mit Reynolds-Zahlen von 104 bis 105 und bei Lufttemperaturen zwischen 0° C und –13°C wurde die Eiswachstumsrate und der Wärme- transport während einer stationären feuchten Vereisung untersucht. Der Koeffizient des konvektiven Wärmeflusses, eine Grösse von primärer Bedeutung, die in die Wärmebilanzgleichung für eine gefrierende Oberfläche eingeht, erwies sich als stark abhängig von dem Gehalt an flüssigem Wasser in der Luft (oder besser gesagt: von dem an der Oberfläche auftreffenden Wasserstrom). Eine theoretische Betrachtung des Koeffizienten des konvektiven Wärmeflusses führt zu der Annahme, dass seine Abhängigkeit durch eine Zunahme der Oberflächen- rauhigkeit und besonders durch eine Wirkung der auf- treffenden Wassertröpfchen auf viskose tiefere Schichten und auf turbulenten Wärmefluss nahe der Vereisungsgrenzfläche verursacht wird. Die geschilderte Auswertung erlaubt die Berechnung einer Zuwachsleistung für jeden Vereisungszustand.

Information

Type
Research Article
Copyright
Copyright © International Glaciological Society 1986
Figure 0

Fig. 1.a. Dependence of ice-mass growth (m1) per unit length for a 5 cm diameter cylinder on the liquid water content, for various temperatures and a wind speed of 15 m/s. and test duration of 15 min. The product eVWb gives the total amount of water falling on the surface. The vertical pointers below show the theoretical critical water content (Wc) for the temperature in question.b. Dependence of ice-mass growth per unit length for a 5 cm diameter cylinder on the liquid water content, for a set of experiments of V = 10 m/s and T = —6°C, and one of 20 m/s and −9°C. Test duration 15 min. The product eVWb gives the total amount of water falling on the surface, and the pointers below show the theoretical critical water content.c. Comparison of the experimental and theoretically calculated ice growth. The experimental curve is based on a set (Ta= −8° C) of measurements from Figure 1a. The graphs ‘1’ and ‘2’ give the theoretically estimated ice growth, using for the convective heat-transfer coefficient the smooth-surface formula of Equation (8) in ‘1’ and the rough-surface formula by Lozowski and others (1983[a]) in ‘2". Both theoretical graphs are given for the droplet size of MVD m 60 μm (lower lines) and 80 μm (upper lines).

Figure 1

Table I.Theoretical Estimates Of The Different Heat Fluxes of Equation (3) For Wind Speeds of 10 and 20 m/s, Temperatures OF − 1° and − 10°C, and Liquid Water Contents of 1 and 4 g/m3

Figure 2

Fig. 2.Time development of the average experimental convective heat-transfer coefficient for various icing conditions. The coefficients hs(10) and hs(15) give the smooth-cylinder coefficients according to Equation (8).

Figure 3

Fig. 3.Fig. 3. a. Dependence of the experimental convective heat-transfer coefficient on the liquid water content in the air for various temperatures and a wind speed of 15 m/s. hs(15) gives the coefficient for a smooth cylinder, b Dependence of the experimental heat-transfer coefficient on the liquid water content in the air for wind speeds of 7.5, 10, and 20 m/s. For symbols, see Figure 3a.

Figure 4

Fig. 4.Fig. 4. Convective heat-transfer coefficient versus the liquid water content for test periods of 1–5 min (V = 15 m/s). The dashed line represents the dependence of 15 min tests in Figure 3.

Figure 5

Fig. 5.Fig. 5. A schematic diagram showing temperature conditions: (a) in a viscous sub-layer in air above an ice—air boundary under dry-growth icing; (b) in the viscous sub-layer in water and in air in an ice-water film-air boundary under wet-growth icing.

Figure 6

Fig. 6.Examples of the convective heat-transfer coefficients in air (h1) and in water (h2) based on Equation (11) and on an assumption of a linear increase of h1 with increasing liquid water content. The experimental coefficients h1 are from Figure 3.

Figure 7

Fig. 7.Accretion efficiency of Equation (1) for a 5 cm diameter cylinder, based on the experimental convective heat-transfer coefficients from Figure 3. The dotted line gives the theoretical accretion efficiency calculated by using the convective heal-transfer coefficient for a smooth cylinder for an air temperature of –14°c and wind speed of 15 m/s.