Adhesion of antibiotic-resistant bacteria to patient-applied thermoplastic medical devices

Published online by Cambridge University Press:  20 April 2026

Catherine Brock*
Affiliation:
Occupational Therapy, Pat Capps Covey College of Allied Health Professions, University of South Alabama, Mobile, USA
Dev Mehta
Affiliation:
Biomedical Sciences, Pat Capps Covey College of Allied Health Professions, University of South Alabama, Mobile, USA
Terrence Ravine
Affiliation:
Biomedical Sciences, Pat Capps Covey College of Allied Health Professions, University of South Alabama, Mobile, USA
*
Corresponding author: Catherine Brock; Email: cwbrock@southalabama.edu

Abstract

Adhesion of antibiotic-resistant bacteria to medical device thermoplastics was evaluated by removal sampling at 1 and 24 hours. Vancomycin-resistant Enterococcus faecalis was removed in greater numbers than either methicillin-resistant Staphylococcus aureus or extended-spectrum beta-lactamase Escherichia coli, suggesting less adhesion and greater potential for transfer to patients wearing contaminated devices.

Information

Type
Concise Communication
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided that no alterations are made and the original article is properly cited. The written permission of Cambridge University Press or the rights holder(s) must be obtained prior to any commercial use and/or adaptation of the article.
Copyright
© The Author(s), 2026. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Figure 1.(A) Hand surgery incisions, (B) hand immobilized in a custom thermoplastic orthosis, (C) test material template, (D) thermoplastic sheets with bacterial inoculum sampling squares: Klarity ThermoSheetsTM | Klarity Contour BlendTM, NC | SpectrumTM Beige (left to right).

Figure 1

Figure 2.Two-way ANOVA of 1-hour log10 CFU data revealed a significant bacterium effect (p ≈ .02), while neither material (p ≈ .60) nor the interaction between bacterium and material (P ≈ .63) was considered significant. Panel C At 24 hours, no effects or interactions achieved significance of P = .05; bacterium P ≈ .10, material P ≈ .49, and interaction P ≈ .13. In all instances, fewer bacteria were recovered after 24 hours of contact than were recovered at 1 hour.