Aeration of water with oxygen microbubbles and its purging effect

Published online by Cambridge University Press:  19 July 2017

Tatsuya Yamashita
Affiliation:
Department of Mechanical Engineering, Keio University, Yokohama 223-8522, Japan
Keita Ando*
Affiliation:
Department of Mechanical Engineering, Keio University, Yokohama 223-8522, Japan
*
†Email address for correspondence: kando@mech.keio.ac.jp

Abstract

In this paper, we apply aeration with oxygen microbubbles to tap water; the intent is to quantitatively evaluate whether nitrogen gas originally dissolved in the water under the atmosphere is purged by the aeration with oxygen microbubbles. Oxygen microbubbles are continuously injected into the circulation system of tap water open to the atmosphere. While the concentration of dissolved oxygen (DO) can be detected by a commercial DO meter, that of dissolved nitrogen (DN) is unavailable. To detect the DN level, we observe the growth of millimetre-sized gas bubbles nucleated at glass surfaces in contact with the aerated water and compare it with the multi-species theory of Epstein and Plesset where the (unknown) DN concentration is treated as a fitting parameter. In the theory, we solve binary diffusion of each gas species (oxygen or nitrogen) in the water independently, under the assumption that the dissolved gases are sufficiently dilute. Comparisons between the experiment and the theory suggest that the DN in the water is effectively purged by the oxygen aeration. The supplemental experiment of aeration with nitrogen microbubbles is also documented to show that the DO can be effectively purged as well.

Information

Type
Papers
Copyright
© 2017 Cambridge University Press 
Figure 0

Figure 1. (a) A schematic diagram of aerating water by a commercial microbubble generator of spiral flow type. The $\text{O}_{2}$ generator is replaced with an $\text{N}_{2}$ generator in supplemental experiments (documented in the appendices). (b) Image of the aeration with oxygen microbubbles produced by the commercial microbubble generator. Oxygen bubbles are ejected from a polyurethane tube whose inner and outer diameter are 7 mm and 9.5 mm, respectively.

Figure 1

Figure 2. A schematic diagram of visualizing the growth of a bubble nucleated at a glass surface in the aerated water.

Figure 2

Table 1. Initial radius of the nucleated bubble (captured in the initial frame), supersaturation from the DO reading, and fitted values of DN supersaturation in experiments (i)–(iv).

Figure 3

Figure 3. A growing bubble attached at the glass surface in experiment (i) under the (maximum) supersaturation of DO at $\unicode[STIX]{x1D701}_{1}=6.0$. The image at $t=0$ corresponds to the initial video frame to capture the nucleated bubble.

Figure 4

Figure 4. Evolution of the growth of the bubble in experiment (i) under the maximum supersaturation of DO at $\unicode[STIX]{x1D701}_{1}=6.0$. The experiment (i) is compared with the multi-species Epstein–Plesset formula (§ 3) with different supersaturation of DN at $\unicode[STIX]{x1D701}_{2}=-0.91$ (fitted) and $\unicode[STIX]{x1D701}_{2}=0$.

Figure 5

Figure 5. (a) Evolution of the growth of the bubble in experiments (i)–(iv). These measurements are compared with the multi-species Epstein–Plesset formula (represented by lines) with the DN concentration fitted (see table 1). (b) Simulated evolution of the mass influx of gas species $i$ into the bubble, $j_{in,i}$.

Figure 6

Figure 6. (a) Evolution of the growth of the bubble in experiments (v) and (vi). These measurements are compared with the multi-species Epstein–Plesset formula with the DN concentration fitted (see table 2). (b) Simulated evolution of the mass influx of gas species $i$ into the bubble, $j_{in,i}$.

Figure 7

Table 2. Initial radius of the nucleated bubble (captured in the initial frame), supersaturation from the DO reading, and fitted values of DN supersaturation in experiments (v)–(vii).

Figure 8

Figure 7. As figure 4, but with the oxygen aeration applied to DN-supersaturated water at $\unicode[STIX]{x1D701}_{2}=1.3$ (fitted according to appendix A).