Contamination on AMS Sample Targets by Modern Carbon is Inevitable

Published online by Cambridge University Press:  17 February 2016

Dipayan Paul
Affiliation:
Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ESRIG), University of Groningen, Nijenborgh 4, 9747 AG, Groningen, the Netherlands.
Henk A Been
Affiliation:
Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ESRIG), University of Groningen, Nijenborgh 4, 9747 AG, Groningen, the Netherlands.
Anita Th Aerts-Bijma
Affiliation:
Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ESRIG), University of Groningen, Nijenborgh 4, 9747 AG, Groningen, the Netherlands.
Harro A J Meijer*
Affiliation:
Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ESRIG), University of Groningen, Nijenborgh 4, 9747 AG, Groningen, the Netherlands.
*
*Corresponding author. Email: h.a.j.meijer@rug.nl.
Rights & Permissions [Opens in a new window]

Abstract

Accelerator mass spectrometry (AMS) measurements of the radiocarbon content in very old samples are often challenging and carry large relative uncertainties due to possible contaminations acquired during the preparation and storage steps. In case of such old samples, the natural surrounding levels of 14C from gases in the atmosphere, which may well be the source of contamination among others, are 2–3 orders of magnitude higher than the samples themselves. Hence, serious efforts are taken during the preparation steps to have the samples pristine until measurements are performed. As samples often have to be temporarily stored until AMS measurements can be performed, storage conditions also become extremely crucial. Here we describe an assessment of this process of contamination in background AMS samples. Samples, both as pressed graphite (on AMS targets) and graphite powder, were stored in various storage conditions (CO2-spiked air) to investigate the extent of contamination. The experiments clearly show that the pressed targets are more vulnerable to contamination than the unpressed graphite. Experiments conducted with enriched CO2-spiked laboratory air also reveal that the contaminating carbon is not only limited to the target surface but also penetrates into the matrix. A combination of measurements on understanding the chemical nature of the graphitization product, combined with long-available knowledge on “adventitious carbon” from the surface science community, brought us to the conclusion that contamination is to a certain extent inevitable. However, it can be minimized, and should be dealt with by sputter-cleaning the samples individually before the actual measurement.

Information

Type
Research Article
Copyright
© 2016 by the Arizona Board of Regents on behalf of the University of Arizona 
Figure 0

Figure 1 Plots illustrating the impact of modern carbon contamination (MCC) and dead carbon contamination (DCC) on age determination: (a) impact of MCC on age determination; (b) impact of DCC on age determination (for clarity shown with log-log axes); (c) impact of MCC on age determination of a background sample (42,500 yr) with respect to sample size; (d) impact of DCC on age determination of a near-contemporary sample (105 yr) with respect to sample size. Typical uncertainties in age determination as performed in Groningen are shown with shaded background. Modern carbon contaminations have the largest effects on samples containing close to background levels of 14C and on very small samples.

Figure 1

Figure 2 Data showing a typical background target measurement. (a) The 14C counts are shown with a solid line, the corresponding 14C/12C with solid circles, and an exponential fit to the counts with the dashed line. (b) Counts accumulated in 10 consecutive sets of eight blocks, shown with squares, and the corresponding 14C/12C averages, shown with circles (error bars representing 1σ standard deviation). Higher counts are observed during the initial part of the measurement due to carbonaceous contaminants on the surface of the target. As the measurement proceeds, cleaner surface is exposed, indicated by the reduced number of counts representative of the background material.

Figure 2

Figure 3 Storage test demonstrating the extent of acquired contamination in pressed targets on exposure to: Storage 1, dry argon; Storage 2, humidified lab air +5% CO2 (0.27±0.02 pMC); and Storage 3, humidified lab air +5% CO2 (980 pMC). (a) 14C counts (raw data) detected during measurements of five pressed targets per storage condition. (b) Average frequency distribution of the counts for five pressed targets per storage condition. (c) Calculated 14C activity (pMC) of the stored targets. For each storage condition, the results shown are the measurements of five samples that were pressed and stored for a period of 10 days before measurements were performed.

Figure 3

Figure 4 (a) Frequency distribution of counts plot for storage tests with graphite in the form of powder (open circles) and pressed targets (open triangles) showing the difference in the level of acquired contamination: Storage 1, humidified lab air +1.5% CO2 (A=50 pMC); Storage 2, humidified lab air +1.5% CO2 (A=108 pMC); and Storage 3, humidified lab air +1.5% CO2 (A=980 pMC). The freshly prepared samples (gray circles) are plotted for comparison in each of the three graphs. (b) Calculated 14C activity (pMC) of the stored pressed targets (open triangles), the stored graphite powder samples (open circles), and the freshly prepared targets (filled gray circles). For each storage condition, the results shown in (a) are the averages for five pressed targets and five graphite powder samples, respectively, that were stored for a period of 10 days before measurements were performed.

Figure 4

Figure 5 (a) Powder X-ray diffraction (PXRD) pattern of iron, graphitization product (GP), and GP after hydrogenation. GP primarily contains carbon in the form of graphite and iron carbide (Fe3C) as indicated by the PXRD pattern. Following hydrogenation at 600°C, Fe3C in GP is converted back to Fe, releasing methane. SEM images of (b) GP and (c) Fe powder (Alfa Aesar, 325 mesh).