Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-08T01:53:33.935Z Has data issue: false hasContentIssue false

An efficient way to evidence and to measure the metal ion fraction in high power impulse magnetron sputtering (HiPIMS) post-discharge with Pt, Au, Pd and mixed targets

Published online by Cambridge University Press:  14 December 2016

S. Cuynet*
Affiliation:
Groupe de Recherche sur l’Energétique des Milieux Ionisés (GREMI), UMR7344 Université d’Orléans – CNRS, 14 rue d’Issoudun BP6744, F-45067 Orléans CEDEX 2, France
T. Lecas
Affiliation:
Groupe de Recherche sur l’Energétique des Milieux Ionisés (GREMI), UMR7344 Université d’Orléans – CNRS, 14 rue d’Issoudun BP6744, F-45067 Orléans CEDEX 2, France
A. Caillard
Affiliation:
Groupe de Recherche sur l’Energétique des Milieux Ionisés (GREMI), UMR7344 Université d’Orléans – CNRS, 14 rue d’Issoudun BP6744, F-45067 Orléans CEDEX 2, France
P. Brault
Affiliation:
Groupe de Recherche sur l’Energétique des Milieux Ionisés (GREMI), UMR7344 Université d’Orléans – CNRS, 14 rue d’Issoudun BP6744, F-45067 Orléans CEDEX 2, France
*
†Email address for correspondence: stephane.cuynet@univ-orleans.fr
Rights & Permissions [Opens in a new window]

Abstract

The proportion of metal ions in a high power impulse magnetron sputtering discharge is key information for the potential development of new materials and new layer architectures deposited by this technique. This paper aims to measure this proportion by using a homemade system consisting of a quartz crystal microbalance and a grid energy analyser assembly. Such a system yields relevant results on the composition of the post-discharge depending on the nature of the gas (Ar, Kr, Xe) and the target materials (Pt, Pd, Au, $\text{Pt}_{50}\text{Au}_{50}$ and $\text{Pt}_{5}\text{Pd}_{95}$ ). In our conditions, the highest proportion of metal ions in the post-discharge are obtained by using Ar gas and reaches 10 %, 12 %, 50 %, 19 % and 88 % for Pt, Au, Pd, $\text{Pt}_{50}\text{Au}_{50}$ and $\text{Pt}_{5}\text{Pd}_{95}$ targets, respectively.

Information

Type
Research Article
Copyright
© Cambridge University Press 2016 
Figure 0

Figure 1. (a) Picture of the experimental set-up for the magnetron sputtering process. (b) Three-dimensional view of the QCM-GEA system placed in front of the magnetron device.

Figure 1

Figure 2. (a) Schematic of the quartz balance and the polarization system. (b,c) Assembling polarization system with quartz microbalance to form the QCM-GEA.

Figure 2

Figure 3. Deposition rate on the QCM-GEA as function of the discriminative voltage $V_{d}$ for various QCM-GEA/target distances and different $\text{U}_{\mathit{HiPIMS}}$: 1000, 1300, 1600, 1900 V. Deposition rates arbitrary normalized to the deposition rate of the $\text{U}_{\mathit{HiPIMS}}$ equal to 1500 V and for a $V_{d}$ null. Image at the bottom right corner shows results for a 50 W DCMS process.

Figure 3

Figure 4. Target currents at $-1500~\text{U}_{\mathit{HiPIMS}}$, pulse duration $100~\unicode[STIX]{x03BC}\text{s}$, frequency 50 Hz, for different targets and gases: respectively Au, Pt, Pd, $\text{Pt}_{50}\text{Au}_{50}$, $\text{Pt}_{5}\text{Pd}_{95}$ and Ar, Kr, Xe.

Figure 4

Figure 5. QCM-GEA normalized deposition rate (full lines) and ions/neutrals ratio $\unicode[STIX]{x1D6E9}$ (dashed lines) as a function of $\text{U}_{\mathit{HiPIMS}}$, for different targets and gases: respectively Au, Pt, Pd, $\text{Pt}_{50}\text{Au}_{50}$, $\text{Pt}_{5}\text{Pd}_{95}$ and Ar, Kr, Xe.