Hostname: page-component-74656f9884-qr5l4 Total loading time: 0 Render date: 2026-11-04T21:18:34.930Z Has data issue: false hasContentIssue false

Deconvolution–convolution treatment on powder diffraction data collected with CuKα X-ray and NiKβ filter

Published online by Cambridge University Press:  29 June 2018

Takashi Ida*
Affiliation:
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
Shoki Ono
Affiliation:
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
Daiki Hattan
Affiliation:
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
Takehiro Yoshida
Affiliation:
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
Yoshinobu Takatsu
Affiliation:
Advanced Ceramics Research Center, Nagoya Institute of Technology, Asahigaoka, Tajimi, Gifu 507-0071, Japan
Katsuhiro Nomura
Affiliation:
Inorganic Functional Materials Research Institute, National Institute of Advanced Industrial Science and Technology, Anagahora, Shimoshidami, Moriyama, Nagoya, Aichi 463-8560, Japan
*
a)Author to whom correspondence should be addressed. Electronic mail: ida.takashi@nitech.ac.jp

Abstract

A method to remove small CuKβ peaks and step structures caused by NiK-edge absorption as well as CuKα2 sub-peaks from powder diffraction intensity data measured with Cu-target X-ray source and Ni-foil filter is proposed. The method is based on deconvolution–convolution treatment applying scale transform of abscissa, Fourier transform, and a realistic spectroscopic model for the source X-ray. The validity of the method has been tested by analysis of the powder diffraction data of a standard LaB6 powder (NIST SRM660a) sample, collected with the combination of CuKα X-ray source, Ni-foil Kβ filter, flat powder specimen and one-dimensional Si strip detector. The diffraction intensity data treated with the method have certainly shown background intensity profile without CuKβ peaks and NiK-edge step structures.

Information

Type
Technical Article
Copyright
Copyright © International Centre for Diffraction Data 2018 
Figure 0

Figure 1. Diffraction intensity data of LaB6 plotted on (a) 2θ and (b) ln sin θ.

Figure 1

Table I. Peak energy E, full width at half maximum W and integrated intensity I for doublet and quartet models for CuKα emission and a quintet model for CuKβ emission (Deutsch et al., 2004).

Figure 2

Figure 2. White X-ray (bremsstrahlung) spectra calculated by the formula of Trincavelli et al. (1998) and Eqs (15)–(17).

Figure 3

Figure 3. Comparison of the mass absorption coefficient spectra of Ni calculated by the Cromer–Liberman method (thick broken line), a simplified model (thin solid line), and the hypothetical spectrum without K-absorption edge (thin broken line).

Figure 4

Figure 4. (a) Overall background profile of observed diffraction data of LaB6 powder measured with a Cu-target X-ray tube and Ni-foil Kβ filter, and the deconvolved–convolved data calculated with the parameters (b) E0 = 45 keV and fB = 0, (c) E0 = 45 keV and fB = 1, (d) E0 = 10 keV and fB = 0.

Figure 5

Figure 5. Background intensity profile of the (a) observed and (b) deconvolved–convolved data in lower diffraction angle range.

Figure 6

Figure 6. Spectroscopic profile used for (a) deconvolution and (b) convolution.