Linear stability analysis of magnetoconvection in finite-sized systems: competition between spatial confinement and magnetic field

Published online by Cambridge University Press:  12 January 2026

Xin Tao
Affiliation:
State Key Laboratory for Strength and Vibration of Mechanical Structures and School of Aerospace, Xi’an Jiaotong University, Xi’an 710049, PR China
Xiaojue Zhu
Affiliation:
Max Planck Institute for Solar System Research, Göttingen 37077, Germany
Ming-Jiu Ni
Affiliation:
School of Engineering Sciences, University of Chinese Academy of Sciences, Beijing 100049, PR China
Yi-Chao Xie*
Affiliation:
State Key Laboratory for Strength and Vibration of Mechanical Structures and School of Aerospace, Xi’an Jiaotong University, Xi’an 710049, PR China
*
Corresponding author: Yi-Chao Xie, yichao.xie@xjtu.edu.cn

Abstract

We present a linear stability analysis of two-dimensional magnetoconvection considering the effects of spatial confinement (characterised by the aspect ratio $\varGamma$) and magnetic field (characterised by the Hartmann number $\textit{Ha}_{i=x,y,z}$ with subscript representing its direction). It is found that when the magnetic field is perpendicular to the convection domain ($y$-direction), it does not affect the onset of convection due to zero Lorentz force. With a magnetic field in the $z$ (vertical) or $x$ (horizontal) directions, the onset of convection is delayed, resulting in a larger critical Rayleigh number $Ra_c$ for the onset of convection. We outline phase diagrams showing the dominating factors determining $Ra_c$. When $\varGamma \leqslant 0.83\textit{Ha}_z^{-0.5}$ for vertical and $\varGamma \leqslant 0.66\textit{Ha}_x^{-1.01}$ for horizontal magnetic field, $Ra_c$ is mainly determined by the geometrical confinement with $Ra_c=502\varGamma ^{-4.0}$. When $\varGamma \geqslant 2^{1/6}\pi ^{1/3}\textit{Ha}_z^{-1/3}$ for vertical and $\varGamma \geqslant 5$ for the horizontal magnetic field, $Ra_c$ is mainly determined by the magnetic field with $Ra_c=\pi ^2\textit{Ha}^2$. In the intermediate regime, both the magnetic field and spatial confinement determine $Ra_c$, and a horizontal magnetic field is found to suppress convection more than a vertical magnetic field. In addition, under a horizontal magnetic field, there exists a subregime characterised by $Ra_c = 9.9\,\varGamma ^{-2.0} \textit{Ha}_x^2$, which is explained by a theoretical model. The magnetic field also modifies the length scale $\ell$. For a vertical magnetic field, $\ell$ decreases with increasing $\textit{Ha}_z$, following $\ell =2^{1/6}\pi ^{1/3}\textit{Ha}^{-1/3}$. For a horizontal magnetic field, when $\varGamma \lt 0.62\textit{Ha}_x^{0.47}$, the flow is a single-roll structure with $\ell$ being the width of the domain. The study thus shed new light on the interplay between magnetic field and spatial confinement.

Information

Type
JFM Papers
Copyright
© The Author(s), 2026. Published by Cambridge University Press
Figure 0

Table 1. Summary of parameter range of magnetoconvection with a vertical magnetic field. Here, $Ra$, $\textit{Pr}$ and $\textit{Ha}$ are the Rayleigh, Prandtl and Hartmann numbers, respectively. The scaling exponent $\beta$ is obtained from the relation $\textit{Nu} \sim (Ra/\textit{Ha}^{2})^{\beta }$, if available in the referenced work. $\varGamma$ is the aspect ratio. For rectangular cells with length $L$, width $W$ and height $H$, $\varGamma _x=L/H$ and $\varGamma _y=W/H$. For cylindrical cells, $\varGamma =D/H$ with $D$ being the diameter of the cell. The references are ($a$) Cioni et al. (2000); ($b$) Aurnou & Olson (2001); ($c$) Burr & Müller (2001); ($d$) Yu et al. (2018); ($e$) Liu et al. (2018); ($f$) Lim et al. (2019); ($g$) Yan et al. (2019); ($h$) Zürner et al. (2020); ($i$) Akhmedagaev et al. (2020); ($j$) Grannan et al. (2022); ($k$) Xu et al. (2023); ($l$) Teimurazov et al. (2024).

Figure 1

Figure 1. Schematics of the two-dimensional magnetoconvection system under consideration. The gravity is pointing in the -$z$-direction. The bottom boundary is held at a temperature $\Delta T$ higher than the top boundary which is kept at constant temperature $T$. The two sidewalls are adiabatic. All the walls satisfy the no-slip and no-penetration velocity boundary condition. The magnetic field can be in either $x$-,$y$- or $z$-direction. The aspect ratio of the domain is defined as $\varGamma =D/H$ with $D$ and $H$ being the width and height of the domain, respectively.

Figure 2

Figure 2. ($a$) Critical Rayleigh number for onset of convection $Ra_c$ versus $\varGamma$ with no magnetic field for flow patterns with odd numbers of rolls in the $x$-direction and those with even numbers of rolls in the $x$-direction. The inset shows the transition from a one-roll pattern to a double-roll pattern with increasing $\varGamma$. (b) $Ra_c$ versus $\varGamma$. The black dashed line marks $Ra_c \sim \varGamma ^{-4.0}$ fitted to the data with $\varGamma \leqslant 1/10$. The horizontal dash-dotted line marks $Ra_c=1708$ with periodic boundary conditions in the $x$-direction. The blue dashed line is the LSA result from Ahlers et al. (2022).

Figure 3

Figure 3. Critical Rayleigh number for the onset of convection $Ra_c$ versus $\varGamma$ for different $\textit{Ha}_z$. The solid lines represent the LSA results, and the circles denote the DNS results at $\textit{Ha}_z = 100$ and $1000$. The horizontal dash-dotted line marks $Ra_c=1708$. For the meaning of the dashed line and the dash-dot-dotted line, see the main text.

Figure 4

Figure 4. (a) Marginal stability curve in a convection cell with periodic horizontal boundary conditions for different $\textit{Ha}_z$ obtained from Chandrasekhar (1952). Here, $a$ is the wavelength. (b) Lines are the same as those in panel (a) with the horizontal axis changed from $a$ to the aspect ratio of a single-roll structure $\varGamma_r$ using $a=\pi/\varGamma_r$, and the circles represent the $Ra_c$ (minimum value of the curve for a given $\textit{Ha}_z$) and corresponding $\varGamma _r$.

Figure 5

Figure 5. Flow pattern at the onset of convection for $\textit{Ha}_z=300$ in a cell with (a) $\varGamma =1/5$ and the number of rolls being $n=1$; (b) $\varGamma =1/2$ and $n=2$; (c) $\varGamma =1$ and $n=4$. The lines with arrows represent the streamlines. The colour represents the normalised kinetic energy of the flow, i.e. $E(x,z)/\kern-1pt\max (E(x,z))$ with $E(x,z)=u^2(x,z)+w^2(x,z)$. Note that the flow patterns shown in the remainder of the paper all follow the same style.

Figure 6

Figure 6. $Ra_c$ versus $\textit{Ha}_z$ for different $\varGamma$. The dashed line represents the asymptotic relation, cf. (1.2). The horizontal dash-dotted line marks $Ra_c=1708$.

Figure 7

Figure 7. Phase diagram showing the dominating factors that determine the onset of convection with a vertical magnetic field. Regime I (blue area) represent the region where $Ra_c$ is mainly determined by geometrical confinement; Regime III (purple area) represents the region where $Ra_c$ is mainly determined by the Lorentz force. Regime II (orange area) represents the region where the geometrical confinement and magnetic confinement are coupled together in determining $Ra_c$. The squares are data points with $0.99Ra_c(\textit{Ha}_z)=Ra_c(\textit{Ha}_z=0)$. The triangles represent the $\varGamma$ corresponding to the single-roll structure of the most unstable mode for a given $\textit{Ha}_z$ in the horizontally periodic layer with top/bottom no-slip boundaries. The red solid line separating regimes I and II is a power-law fit to the squares with $\varGamma _{c_1}=0.83\textit{Ha}_z^{-0.50}$. The black solid line separating regimes II and III is $\varGamma _{c_2} = 2^{1/6} \pi ^{1/3} \textit{Ha}_z^{-1/3}$.

Figure 8

Figure 8. Flow pattern at the onset of convection in a cell with $\varGamma =2$ and for (a) $\textit{Ha}_z=0$ and the number of rolls being $n=2$; (b) $\textit{Ha}_z=30$ and $n=3$; (c) $\textit{Ha}_z=100$ and $n=5$; (d) $\textit{Ha}_z=1000$ and $n=12$. For each panel, the lines with arrows represent streamlines and the colour represents the normalised kinetic energy.

Figure 9

Table 2. Summary of LSA results for the critical Rayleigh number $Ra_c$ and the number of rolls $n$, evaluated at representative Hartmann numbers $\textit{Ha}_z$ and aspect ratios $\varGamma$. In each data entry, the first value denotes $Ra_c$ and the second value denotes $n$.

Figure 10

Figure 9. (a) Number of rolls $n$ as a function of $\textit{Ha}_z$ for different $\varGamma$. (b) Wavenumber $a$ calculated from the number of rolls in panel (a) using $n \pi / \varGamma$ as a function of $\textit{Ha}_z$ for different $\varGamma$. The dashed line represents the asymptotic relation, cf. (1.3).

Figure 11

Figure 10. $Ra_c$ versus $\varGamma$ for different $\textit{Ha}_x$. The solid lines represent the LSA results, and the circles denote the DNS results at $\textit{Ha}_x = 100$ and $1000$. The dashed line and the horizontal dash-dotted line are the same as those in figure 2(b). The black solid line marks $Ra_c\sim \varGamma ^{-2}$.

Figure 12

Figure 11. (a) $Ra_c$ versus $\textit{Ha}_x$ for different $\varGamma$ shown by the solid lines. For a given $\varGamma$ and sufficiently large $\textit{Ha}_x$, the data can be fitted by a power law, i.e. $Ra_c=S\textit{Ha}^2$ with the dependence of the prefactor $S$ on $\varGamma$ shown in panel (b). The dashed line in panel (a) represents the asymptotic relation, cf. (1.3) and the horizontal dash-dotted line marks $Ra_c=1708$. (b) Prefactor $S$ versus $\varGamma$. The dash-dotted line marks the asymptotic value of $\pi ^2$ and the dashed line marks a fitting to the data, giving $S=9.9\varGamma ^{-2.0}$.

Figure 13

Figure 12. (a) Compensated plot of $Ra_c$ versus $\varGamma ^{-2}$. The up-pointing triangle marks the left boundary of the $Ra_c=K\kern-1pt\varGamma ^{-2}$ scaling region, while the down-pointing triangle marks the right boundary. The squares are data points with $0.99Ra_c(\textit{Ha}_x)=Ra_c(\textit{Ha}_x=0)$. (b) Prefactor $K$ versus $\textit{Ha}_x$. For $\textit{Ha}_x\gt 30$, the data can be fitted by a power law, i.e. $K=12.2\textit{Ha}_x^{1.98}$.

Figure 14

Figure 13. Flow patterns at the onset of convection in a cell with $\varGamma =1/5$ for (a) $\textit{Ha}_x=0$, (b) $\textit{Ha}_x=1000$. The black lines with arrows represent streamlines and the colour represents the normalised kinetic energy. (c) Horizontal profiles of normalised vertical velocity $w^*$ at $z = 1/2$ for the two patterns in (a,b), where $w^* = w / \max (w)$.

Figure 15

Figure 14. Phase diagram showing the dominating factors that determine the onset of convection with a horizontal magnetic field. Regime I (blue area) represents the region where $Ra_c$ is mainly determined by geometrical confinement; Regime III (purple area) represents the region where $Ra_c$ is mainly determined by the Lorentz force. Regime II (orange area) represents the region where the geometrical confinement and magnetic confinement are coupled together in determining $Ra_c$. The squares are data points with $0.99Ra_c(\textit{Ha}_z)=Ra_c(\textit{Ha}_z=0)$. The red solid line separating regimes I and II is a power law fit to the squares with $\varGamma_{c_3}=0.66Ha_x^{-1.01}$. The black solid line separating regimes II and III is $\varGamma _{c_4} = 5$. The boundaries of the regime with $Ra_c=9.9\varGamma ^{-2.0}\textit{Ha}_x^{2}$ is marked by the triangles.

Figure 16

Table 3. Summary of LSA results for the critical Rayleigh number $Ra_c$ and the number of rolls $n$, evaluated at representative Hartmann numbers $\textit{Ha}_x$ and aspect ratios $\varGamma$. In each data entry, the first value denotes $Ra_c$ and the second value denotes $n$.

Figure 17

Figure 15. Flow pattern at the onset of convection in a cell with $\varGamma =2$ and for (a) $\textit{Ha}_x=0$ and the number of rolls being $n=2$; (b) $\textit{Ha}_x=30$ and $n=1$; (c) $\textit{Ha}_x=100$ and $n=1$; (d) $\textit{Ha}_x=1000$ and $n=1$. For each panel, the lines with arrows represent streamlines and the colour represents the normalised kinetic energy.

Figure 18

Figure 16. Critical aspect ratio $\varGamma ^*$ for the transition between double-roll structure and single-roll structure as a function of $\textit{Ha}_x$. For $\textit{Ha}_x \ge 30$, the data can be fitted by a power law shown as the solid line, i.e. $\varGamma ^* = 0.62 \textit{Ha}_x^{0.47}$.

Figure 19

Table 4. Validation of LSA accuracy. The $Ra_c$ results for typical values of $\textit{Ha}_z$ and $\textit{Ha}_x$ at several representative $\varGamma$ values for different orders $(M, N)$ are listed.

Figure 20

Figure 17. Normalised kinetic energy contour for $\textit{Ha}_x = 300$ and $\varGamma =2$ with the order of mode numbers being (a) $M = N = 60$ and (b) $M = N = 120$. The calculated $Ra_c$ is $1.126\times 10^6$ and $1.125\times 10^6$ in panels (a) and (b), respectively.

Figure 21

Figure 18. Determination of the critical Rayleigh number $Ra_c$ for the onset of convection in a $\varGamma =1$ cell based on $\textit{Nu}$ obtained from DNS with (a) $\textit{Ha}_z=100$ and (b) $\textit{Ha}_x=100$. The solid line is a linear fit to the data above the onset of convection and the dashed line marks $\textit{Nu}=1$ for the conduction state.

Figure 22

Table 5. Simulation details. Here, $\textit{Ha}_{i=x,z}$ is Hartmann number with its subscript indicates the direction of the magnetic field. $Ra$ is the Rayleigh number; $\textit{Nu}$ is the Nusselt number based on volume-averaged heat flux; $\textit{Nu}_{\varepsilon _{u+J}}$ is the Nusselt number based on kinetic energy dissipation rate via viscous and Ohmic counterparts; $\textit{Nu}_{\varepsilon _T}$ is the Nusselt number based on the thermal dissipation rate; $\varGamma$ is aspect ratio of the domain; $N_x$ and $N_z$ represent the resolution of the grid in horizontal and vertical directions, respectively.

Figure 23

Figure 19. Comparison of the flow pattern at the onset of convection in a $\varGamma = 1$ cell between LSA and DNS. (a, c) LSA results, (b, d) DNS results. (a, b) For $\textit{Ha}_z=100$ and (c, d) for $\textit{Ha}_x=100$. For each panel, the lines with arrows represent streamlines and the colour represents the normalised kinetic energy.