Impacts of resonant magnetic perturbations on edge carbon transport and emission on EAST with EMC3-EIRENE modelling

Published online by Cambridge University Press:  15 May 2020

S. Y. Dai*
Affiliation:
Key Laboratory of Materials Modification by Laser, Ion and Electron Beams (Ministry of Education), School of Physics, Dalian University of Technology, Dalian116024, PR China DUT-BSU Joint Insititute, Dalian University of Technology, Dalian116024, PR China
H. M. Zhang
Affiliation:
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei230031, PR China
B. Lyu*
Affiliation:
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei230031, PR China
L. Wang
Affiliation:
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei230031, PR China
Y. Feng
Affiliation:
Max-Planck-Institute für Plasmaphysik, D-17491Greifswald, Germany
Z. X. Wang
Affiliation:
Key Laboratory of Materials Modification by Laser, Ion and Electron Beams (Ministry of Education), School of Physics, Dalian University of Technology, Dalian116024, PR China
D. Z. Wang
Affiliation:
Key Laboratory of Materials Modification by Laser, Ion and Electron Beams (Ministry of Education), School of Physics, Dalian University of Technology, Dalian116024, PR China
*
†Email addresses for correspondence: daishuyu@dlut.edu.cn, blu@ipp.ac.cn
†Email addresses for correspondence: daishuyu@dlut.edu.cn, blu@ipp.ac.cn
Rights & Permissions [Opens in a new window]

Abstract

The modelling of edge carbon transport and emission on EAST tokamak under resonant magnetic perturbation (RMP) fields has been conducted with the three-dimensional edge transport code EMC3-EIRENE. The measured vertical distribution of CVI emission by the extreme ultraviolet spectrometer system for the perturbed case shows a reduction in the CVI emission by 20 % compared to the equilibrium case. The chord-integrated CVI emission can be reconstructed by EMC3-EIRENE modelling, which presents an increase in the CVI emission with RMP fields. The discrepancy between experiments and simulations has been investigated by parameter study to examine the sensitivity of the simulation results on the edge plasma conditions and the impurity perpendicular transport. It is found that the variation of edge plasma conditions for the equilibrium case cannot resolve the discrepancy in the CVI emission between simulations and measurements. The simulations with enhanced impurity perpendicular transport coefficient allows a reasonable agreement with the measured reduction of CVI emission.

Information

Type
Research Article
Copyright
© The Author(s), 2020. Published by Cambridge University Press
Figure 0

Figure 1. Three-dimensional schematic view of the RMP coil system (a), top view of toroidal locations of the EAST ports, EUV spectrometer and RMP coils (b) and schematic view of the EUV spectrometer system (c) on EAST.

Figure 1

Figure 2. Time evolution of plasma current (a), injected power (b), line-averaged electron density (c), stored energy (d) and RMP coil currents for upper and lower arrays (e) for shot #67578.

Figure 2

Figure 3. Profiles of the vertical distributions of CVI (33.7 Å) emission intensities measured by the EUV spectrometer for the cases with and without RMP applications.

Figure 3

Figure 4. Two-dimensional distributions of the connection length for the cases without RMP (a) and with RMP (b) applications by EMC3-EIRENE modelling at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$. The Poincaré plot for the perturbed fields is superimposed on the connection length distribution in figure 4(b).

Figure 4

Figure 5. Horizontal profiles of the electron density (a) and temperature (b) in the experiments and simulations at the midplane of EAST for the perturbed case (shot #67578, $t_{2}=5.5~\text{s}$). A mapping of the electron density and temperature profiles at the inboard midplane has been performed according to the measurements at the outboard midplane.

Figure 5

Figure 6. Two-dimensional distributions of $\text{C}^{1+}$ (a), $\text{C}^{2+}$ (b), $\text{C}^{3+}$ (c), $\text{C}^{4+}$ (d), $\text{C}^{5+}$ (e) and $\text{C}^{6+}$ (f) by EMC3-EIRENE modelling for the perturbed case at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$.

Figure 6

Figure 7. Two-dimensional distribution of the CVI emission intensity by EMC3-EIRENE modelling for the perturbed case at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$. The green dashed lines indicate the vertical observation range of the EUV spectrometer.

Figure 7

Figure 8. Profiles of the vertical distributions of the CVI emission intensities calculated according to EMC3-EIRENE simulation results for the cases with and without RMP applications at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$.

Figure 8

Figure 9. Profiles of the vertical distributions of the CVI emission intensity ratio between the perturbed and equilibrium cases measured by the EUV spectrometer and calculated according to EMC3-EIRENE modelling ($D_{\text{imp}}=0.4~\text{m}^{2}~\text{s}^{-1}$) at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$.

Figure 9

Figure 10. Profiles of the vertical distributions of the CVI emission intensity ratio between the perturbed and equilibrium cases measured by the EUV spectrometer and calculated according to EMC3-EIRENE modelling ($D_{\text{imp}}=0.4~\text{m}^{2}~\text{s}^{-1}$) at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$. The different upstream plasma densities ($n_{u}=0.73\times 10^{19}$, $0.85\times 10^{19}$ and $1.0\times 10^{19}~\text{m}^{-3}$) are used for the equilibrium case ($D_{\bot }=0.4~\text{m}^{2}~\text{s}^{-1}$ and $\unicode[STIX]{x1D712}_{\bot }=2.0~\text{m}^{2}~\text{s}^{-1}$).

Figure 10

Figure 11. Two-dimensional distributions of $\text{C}^{5+}$ densities for $n_{u}=0.73\times 10^{19}~\text{m}^{-3}$ (a) and $1.0\times 10^{19}~\text{m}^{-3}$ (b) by EMC3-EIRENE modelling for the equilibrium case at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$.

Figure 11

Figure 12. Profiles of the vertical distributions of the CVI emission intensity ratios between the perturbed and equilibrium cases measured by the EUV spectrometer and calculated according to EMC3-EIRENE modelling ($D_{\text{imp}}=0.4~\text{m}^{2}~\text{s}^{-1}$) at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$. The different upstream plasma densities ($n_{u}=0.73\times 10^{19}$, $0.85\times 10^{19}$ and $1.0\times 10^{19}~\text{m}^{-3}$) are used for the equilibrium case. $D_{\bot }=0.4~\text{m}^{2}~\text{s}^{-1}$ and $\unicode[STIX]{x1D712}_{\bot }=1.0~\text{m}^{2}~\text{s}^{-1}$ for (a) and $D_{\bot }=0.4~\text{m}^{2}~\text{s}^{-1}$ and $\unicode[STIX]{x1D712}_{\bot }=3.0~\text{m}^{2}~\text{s}^{-1}$ for (b).

Figure 12

Figure 13. Profiles of the vertical distributions of the CVI emission intensity ratios between the perturbed and equilibrium cases measured by the EUV spectrometer and calculated according to EMC3-EIRENE modelling for different impurity perpendicular diffusivities $D_{\text{imp}}=3.0$, 3.5 and $4.0~\text{m}^{2}~\text{s}^{-1}$ for the perturbed case at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$.

Figure 13

Figure 14. Two-dimensional distribution of the CVI emission intensity by EMC3-EIRENE modelling for the perturbed case with $D_{\text{imp}}=3.5~\text{m}^{2}~\text{s}^{-1}$ at the toroidal angle of $\unicode[STIX]{x1D711}=56.25^{\circ }$. The green dashed lines indicate the vertical observation range of the EUV spectrometer.