Hostname: page-component-7b7567c8c-tnzcf Total loading time: 0 Render date: 2026-11-13T18:14:33.598Z Has data issue: false hasContentIssue false

A randomized trial comparing the intraoperative durability of double-gloving with Biogel® surgical gloves to 3 comparators

Published online by Cambridge University Press:  10 October 2024

Michelle Doll*
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Asmaa Namoos
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Le Kang
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Jibanananda Satpathy
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Michael J. Feldman
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Anthony Cassano
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Jaime Bohl
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Michel B. Aboutanos
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Brian Cameron
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Jason Kim
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Celine Asbury
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Mahdee Haque
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Olivia Hess
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
Henrik Ahlbom
Affiliation:
Molnlycke Healthcare, Gothenburg, Sweden
Gonzalo Bearman
Affiliation:
Virginia Commonwealth University School of Medicine, Richmond, VA, USA
*
Corresponding author: Michelle Doll; Email: michelle.doll@vcuhealth.org

Abstract

Objective:

To determine and compare the intraoperative durability of 4 major surgical glove brands.

Design, Setting, and Participants:

This study is a randomized open-label clinical trial in which surgical gloves from 4 manufacturers are randomized to 5 surgical subspecialty study groups: (1) orthopedic surgery, (2) neurosurgery, (3) colorectal surgery, (4) trauma or acute general surgery, and (5) cardiac and plastic surgeries. The study was divided into 10 periods, with a cross-over design, and was conducted at a tertiary care academic medical center. Participants were licensed and certified physicians, physicians-in-training, scrub nurses, or technicians working within the sterile field.

Interventions:

Participants from each study group were randomly assigned to 1 of 4 surgical glove manufacturer types and subsequently rotated through the other 3 glove brands such that each participant acted as their own control in the sequential cross-over design.

Main Outcomes and Measures:

The primary outcome was to determine and compare the intraoperative failure rate of Biogel® Sterile Surgical undergloves against sterile surgical undergloves from 3 other manufacturers, both as a combined competitor group and individually.

Results:

There were no differences between brands with respect to the primary outcome of underglove intraoperative failures. Brand 1 wearers were slightly more likely to detect glove failures when they occurred.

Conclusion:

The durability of surgical gloves intraoperatively is similar across 4 major glove manufacturers. Detection of intraoperative failures is infrequent, though specific glove characteristics may promote enhanced detection. Recognition of glove perforations intraoperatively is important in the maintenance of a maximally sterile field.

Trial Registration:

ClinicalTrials.gov Identifier: NCT03344354.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2024. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Table 1.Study randomization and cross-over

Figure 1

Table 2.Primary and secondary endpoints, intention to treat

Figure 2

Figure 1.CONSORT flow diagram.

Figure 3

Table 3.Primary and secondary endpoints, per protocol

Figure 4

Table 4.Adjusted analysis

Figure 5

Table 5.Adjusted analysis

Figure 6

Table 6.Provider satisfaction scores* for key glove features by brand