Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-10T12:43:53.382Z Has data issue: false hasContentIssue false

Particle densities, velocities and size distributions in large avalanches from impact-sensor measurements

Published online by Cambridge University Press:  14 September 2017

Mark Schaer
Affiliation:
Eidgenössisches Institut für Schnee- und Lawinenforsckung (SLF), CH-7260 Davos Dorf Switzerland
Dieter Issler
Affiliation:
Eidgenössisches Institut für Schnee- und Lawinenforsckung (SLF), CH-7260 Davos Dorf Switzerland
Rights & Permissions [Opens in a new window]

Abstract

In winter 1998/99, high-frequency pressure measurements with 10 cm sensors mounted 1–19 m above ground were carried out in the upper run-out zone of the avalanche test site at Vallée de la Sionne, Switzerland. Two large dry-snow avalanches clearly revealed a three-layered structure, with surprisingly low pressures in the suspension (or powder-snow) layer. The height of the saltation layer varied between 1 and > 3 m. From the duration, impulse and frequency of single-particle impacts (observed in the saltation layer and intermittently in the dense flow),particle-size and velocity distribution functions as well as strongly varying saltation-layer densities were found. With improved methods for peak detection and correction for grazing impacts, pressure measurements will become premier tool for testing granular flow models.

Information

Type
Research Article
Copyright
Copyright © the Author(s) [year] 2001
Figure 0

Table 1. Characteristic properties of studied avalanche events

Figure 1

Fig. 1. Pressure measurements at wedge, avalanche of 12 December 1998. Black line: sensor 0.9 m above ground; gray line: sensor 2.1m above ground.

Figure 2

Fig. 2. Pressure measurements at wedge and tubular mast, avalanches of 30 January 1999 (left column) and 10 February 1999 (right column). (a,f) Raw datafrom sensors at 3.0 m (gray lines in (a), black lines in (/)) and3.9m (black lines in (a), gray lines in (/)) on wedge (lower sensors were inside snow cover). (b,g) Detail view of wedge measurements. (c,h) Filtered data from tubular mast at 7.0 m (gray lines) and 19.0 m (black lines), (d, e, i,j) Enlarged views of data from mast.

Figure 3

Fig. 3. Correction procedure for NZJ(t) in the u-d plane. The images of class (i, 3) for two different values of the excentricity s are shown. For each image determine the area fractions rij,i’j’ (s) it occupies within size class (i’,j’).

Figure 4

Fig. 4. Scatter plot of apparent particle velocities vs time at 3.0 m above ground, avalanche of 30 January 1999. Quasistatic pressure was removed before peak detection. Particles whose velocity was likely overestimated were discarded (open circles).

Figure 5

Fig. 5. Time evolution of apparent particle velocities at 3.0 m (dashed line), 3.9 m (full black line) and 7.0 m (gray line), avalanches of 30 January (a) and 10 February 1999 (b).

Figure 6

Fig. 6. Scatter plot of apparent particle velocity vs apparent particle diameter at 3.0 m (crosses), 3.9 m (gray circles) and 7.0 m (black circles). Avalanche of 30 January 1999, interval 101–102 s.

Figure 7

Fig. 7. Time evolution of apparent particle diameters at 3.0 m (dashed line), 3.9 m (full black line) and 7.0 m (gray line), avalanches of 30 January (a) and 10 February 1999 (b).

Figure 8

Fig. 8. Comparison of normalized velocity distribution functions for different particle-size classes, before corrections for excentric impacts. Avalanche of 30 January 1999, interval 103–1035 s, sensor on mast at 7 m.

Figure 9

Fig. 9. Partial densities of different particle-size classes vs time. Avalanche of 10 February 1999, sensor at 7 m above ground. Widths of columns correspond to time-integration intervals. Estimated total density is plotted as line above partial densities.