1. Introduction
The thermal convection generated by heating from the bottom and cooling from the top in a closed cell is known as Rayleigh–Bénard convection (RBC), a classic model for studying complex convective phenomena (Ahlers, Grossmann & Lohse Reference Ahlers, Grossmann and Lohse2009; Chillà & Schumacher Reference Chillà and Schumacher2012; Verma, Kumar & Pandey Reference Verma, Kumar and Pandey2017). The dimensionless number quantifying the heat transfer efficiency in RBC is the Nusselt number (
$\textit{Nu}$
), defined as
$\textit{Nu}=qH/(\lambda \Delta T)$
, which is the ratio of the heat flux due to convection to that which would be transported solely by conduction. Here
$q$
is the input heat flux supplied at the bottom plate and
$\lambda$
is the thermal conductivity of the working fluid. The dimensionless parameter that controls the intensity of RBC is the Rayleigh number
$Ra=\alpha g \Delta TH^3/(\nu \kappa )$
, where
$\nu$
,
$\kappa$
,
$\alpha$
,
$g$
and
$\Delta T$
are the kinematic viscosity, the thermal diffusivity, the thermal expansion coefficient, the gravitational acceleration constant and the temperature difference along the direction of gravity, respectively.
It is well known that the thermal boundary layer plays a crucial role in convection systems, particularly in global heat transport. The efficiency of global heat transport is directly affected by the thermal boundary layer since the majority of the temperature drop occurs within it. The temperature profile in RBC systems, particularly for fluids with moderate to high Prandtl numbers (
$\textit{Pr}\gt 0.8$
), has been extensively studied (Wang & Xia Reference Wang and Xia2003; Zhou et al. Reference Zhou, Li, Lu and Liu2011; Shi, Emran & Schumacher Reference Shi, Emran and Schumacher2012; Wagner, Shishkina & Wagner Reference Wagner, Shishkina and Wagner2012; Zhou & Xia Reference Zhou and Xia2013; Scheel & Schumacher Reference Scheel and Schumacher2014), with these studies typically classifying the temperature distribution from the heated bottom plate to the centre of the cell into three distinct regions: the thermal boundary layer, the mixing zone and the bulk region. In the thermal boundary layer, a steep temperature gradient develops due to conductive heat transfer from the bottom plate, which acts as the dominant resistance to heat transport. The thickness of the boundary layer is determined by
$Ra$
and
$\textit{Pr}$
, with higher-
$\textit{Pr}$
fluids generally exhibiting thinner thermal boundary layers (Grossmann & Lohse Reference Grossmann and Lohse2000; Scheel & Schumacher Reference Scheel and Schumacher2014). As the fluid enters the mixing zone, convective flow begins to take over, leading to a decrease in the temperature gradient, and heat transport transitions from conduction-dominated to convection-dominated (Shraiman & Siggia Reference Shraiman and Siggia1998; Zhou et al. Reference Zhou, Li, Lu and Liu2011). In the bulk region, the temperature becomes more homogeneous as the convective motion redistributes thermal energy, smoothing out spatial temperature variations (Wagner et al. Reference Wagner, Shishkina and Wagner2012). These findings highlight the critical role of the thermal boundary layer in controlling overall heat transfer efficiency and form the foundation for understanding the scaling relationships among
$\textit{Nu}$
,
$Ra$
and
$\textit{Pr}$
(Grossmann & Lohse Reference Grossmann and Lohse2001; Wang & Xia Reference Wang and Xia2003). The temperature profile resulting from these three regions typically exhibits a monotonic decrease in temperature with increasing distance from the heating plate, eventually reaching a nearly constant value in the bulk region.
However, deviations from this expected profile, such as inverse temperature gradients (regions where temperature increases with height), have been observed under certain conditions. These anomalous temperature distributions are particularly intriguing, as they reveal complex interactions between flow structures, boundary layers and geometry. Segawa, Naert & Sano (Reference Segawa, Naert and Sano1998) observed weak inverse temperature gradients near the centre of a cylindrical cell (
$\varGamma =1$
) in mercury, attributing the phenomenon to the stratification effect. Chu & Goldstein (Reference Chu and Goldstein1973) observed stable inverse temperature gradients outside the boundary layer in a water-filled rectangular cell at
$Ra \lt 8.01 \times 10^5$
, and explained the effect by the presence of relatively warm, stable ‘blobs’ near the cold plate, as captured in flow visualisations. Similarly, Wang & Xia (Reference Wang and Xia2003) reported inverse gradients outside the boundary layer in water convection experiments in rectangular cells, while noting their absence in cylindrical geometries. They emphasised the role of cell geometry in generating such temperature anomalies. Furthermore, Wan et al. (Reference Wan, Wei, Verzicco, Lohse, Ahlers and Stevens2019) systematically studied fluids of various Prandtl number in a cylindrical cell and observed positive temperature gradients (inverse behaviour) both at the centre and near the sidewalls, resulting from plume dynamics that transports warm or cold fluid across the cell before it returns to the centre.
To date, a detailed understanding of this phenomenon in low-
$\textit{Pr}$
fluids remains limited due to experimental and computational challenges. In thermal convection of low-
$\textit{Pr}$
fluids, such as liquid metals, the viscous boundary layer is embedded within the thermal boundary layer, suggesting a direct influence of the thermal boundary layer on the bulk flow (Takeshita et al. Reference Takeshita, Segawa, Glazier and Sano1996). This strong coupling between flow structure and heat transfer leads to distinct convection behaviours compared with moderate- or high-
$\textit{Pr}$
fluids. In low-
$\textit{Pr}$
-liquid convection, inertial effects dominate, leading to more chaotic and turbulent flows at the same
$Ra$
, which contrasts with the more stable flow regimes in high-
$\textit{Pr}$
fluids (Schumacher, Götzfried & Scheel Reference Schumacher, Götzfried and Scheel2015; Pandey & Verma Reference Pandey and Verma2016; Pandey, Scheel & Schumacher Reference Pandey, Scheel and Schumacher2018). Despite these unique characteristics, the study of temperature distribution in low-
$\textit{Pr}$
fluids has been relatively underexplored due to the challenges associated with both experimental and numerical techniques. Regarding experiments, due to the opacity of liquid metals, a primary challenge is to find suitable measurement techniques to obtain flow behaviour (Zürner et al. Reference Zürner, Schindler, Vogt, Eckert and Schumacher2020). For simulations, studying boundary layers in low-
$\textit{Pr}$
fluids necessitates resolving very fine spatial and temporal scales, demanding significant computational resources (Schumacher et al. Reference Schumacher, Bandaru, Pandey and Scheel2016; Pandey et al. Reference Pandey, Scheel and Schumacher2018). In most boundary-layer measurement experiments, a rectangular cell is typically used, as many theoretical models are based on two-dimensional assumptions (Brown & Ahlers Reference Brown and Ahlers2006; Xi, Zhou & Xia Reference Xi, Zhou and Xia2006). This approach avoids complications arising from the twisting and oscillatory behaviours that large-scale flows in cylindrical cells often exhibit (Xi et al. Reference Xi, Zhou, Zhou, Chan and Xia2009; Zhou et al. Reference Zhou, Xi, Zhou, Sun and Xia2009). These complex flow structures in cylindrical geometries make it difficult to attribute temperature changes along a single vertical direction to a clear cause. By focusing on a quasi-two-dimensional cell, we aim to isolate and better understand the temperature distribution in low-
$\textit{Pr}$
fluids, particularly as it relates to flow structures.
To address these challenges and extend understanding of inverse temperature gradients in low-
$\textit{Pr}$
convection, we investigate the temperature structure of a liquid metal (low-
$\textit{Pr}$
fluid) in a quasi-two-dimensional rectangular convection cell using high-precision displacement control techniques. By systematically analysing the vertical temperature profiles and their relationship with the underlying flow structures, we aim to clarify the mechanisms responsible for the emergence of inverse temperature gradients in such systems. Our work contributes new insights into the fundamental physics of thermal boundary layers and non-trivial heat transport phenomena in low-Prandtl-number convection.
(a) Schematic diagram of the experimental system, including a high-precision motor, a thermistor stainless steel shell (outer diameter of 2 mm), with the cables arranged inside, and a convection cell with a size of
$126\,\textrm{mm} \times 25.2\,\textrm{mm} \times 126\,\mathrm{mm}$
. Here
$z$
represents the distance between the thermistor and the bottom plate. (b) Schematic diagram of installation of the convection system.

2. Experimental system
We adopt a quasi-two-dimensional rectangular cell with width-to-height ratio of
$0.2$
to study the temperature characteristics of RBC filled with GaInSn, which is in a liquid state at room temperature. To measure the temperature distribution along the centre of the convection cell, as shown in figure 1(a), a high-precision thermistor with a head diameter of
$0.38$
mm (model GAG22K7MCD419) is installed on the movable platform with a minimum step size of
$0.001$
mm. The thermistor is calibrated against a standard platinum resistance thermometer, ensuring measurement accuracy within
$0.01\,^{\circ }{\textrm C}$
. The thermistor is inserted through a stainless steel tube with an inner diameter of 1 mm and an outer diameter of 2 mm, with only the head exposed outside the tube. The other end of the stainless steel tube is sealed with sealant to prevent the liquid metal from flowing out due to the capillary effect. To accurately measure the temperature profile, we set up 77 measurement positions in the mid-height region of the cell. The temperature probes remained at each position for 30 minutes, with the first 5 minutes spent stationary to prevent any vibration-induced measurement errors after probe movement, followed by 25 minutes of data acquisition. The resistance measurements are conducted using a single-channel, 7.5-digit digital multimeter (Keysight 34470A), which has a sampling rate of approximately 30 Hz. For certain experimental conditions, we also measure the temperature distribution across the entire height of the cell, from the bottom plate to the top plate. Moreover, we also install a pair of vertically aligned temperature sensors on the stainless steel tube to analyse the temperature correlation at each position, a method previously proposed by Zhou & Xia (Reference Zhou and Xia2001). Therefore, the local flow characteristics can be obtained according to the measured time delay between two adjacent sensors. To be more specific, let us assume that one of our two temperature sensors is located inside the boundary layer, while the other is located outside of it. In that case, the correlation coefficient between the two sensors will be lower than if both sensors were placed outside the boundary layer. To achieve precise measurements of the thermal boundary layer and heat transfer characteristics, careful thermal shielding arrangements are implemented in the experimental set-up. A schematic of the convection cell installation is shown in figure 1(b). The convection cell is mounted on a hollow support tube situated in a copper basin. This configuration prevents direct contact between the heated bottom plate of the convection cell and the copper basin, thereby avoiding direct thermal influence from the basin on the bottom plate. Heating pads are affixed to the outer wall of the copper basin, and their power is controlled in real time via a feedback program to ensure that the basin’s average temperature matches that of the heated bottom plate. This thermal matching effectively suppresses downward heat leakage from the bottom plate. The copper basin is supported by a horizontal plate equipped with three adjustable legs. By fine-tuning the height of these legs, the horizontal alignment of the convection cell can be maintained within
$0.5^{\circ }$
. The entire convection system is enclosed in a water-cooled insulation cover made of copper. A temperature control program keeps the internal air temperature of this cover stable at
$35\,^{\circ }\rm C$
, providing a consistent thermal environment. Insulation cotton is used to fill the gap between the convection cell and the water-cooled insulation cover, preventing air flow from disturbing the heat transfer process of the cell. The entire apparatus is mounted on bakelite for structural stability and insulation. In the present experiments, by varying the temperature difference between the top and bottom plates,
$\Delta T$
, but keeping the average temperature of the upper and lower plates at
$35\,^{\circ }\rm C$
, we can achieve
$Ra$
from
$5.76 \times 10^5$
to
$2.28 \times 10^7$
.
3. Results and discussion
For the first step, we plot the variation of mean temperature
$\overline {T}$
with
$z$
for six
$Ra$
in figure 2, where
$z$
represents the distance from the bottom plate. As the temperature probe moves away from the bottom plate, the mean temperature
$\overline {T}$
drops sharply over a short distance. However,
$\overline {T}$
does not decrease to a level near the centre temperature; instead, it continues to drop below the centre temperature before gradually rising back to the centre temperature as it approaches the cell centre. By examining the point at which the temperature is at its lowest, we observe that it falls within the range of
$z/H=0.1$
and
$z/H=0.3$
, shifting closer to the bottom plate as
$Ra$
increases. This inverse temperature gradient is similar to those reported in previous studies (Chu & Goldstein Reference Chu and Goldstein1973; Segawa et al. Reference Segawa, Naert and Sano1998; Wang & Xia Reference Wang and Xia2003; Wan et al. Reference Wan, Wei, Verzicco, Lohse, Ahlers and Stevens2019).
(a–f) The measured temperature profiles along the centreline in the convection cell under six different
$Ra$
. Here
$z$
is normalised by the height of the cell
$H$
and
$\overline {T}$
represents the mean temperature at each measured location.

The temperature profile is further non-dimensionalised and compared against theoretical predictions. Figure 3(a) shows the temperature distribution at six different Ra values, where the temperature distribution is represented by
$\theta$
, with
$\theta =[T_{\textit{bot}}-\overline {T}(z)]/ (T_{\textit{bot}}-T_{\textit{bulk}})$
and
$T_{\textit{bulk}}=(T_{\textit{bot}}+T_{\textit{top}})/2$
. The non-dimensional temperature profile
$\theta$
also exhibits an inverse temperature gradient. Our experimental data show good agreement with the rising segment of the profile reported by Shishkina et al. (Reference Shishkina, Horn, Emran and Ching2017), while the theoretical prediction does not capture the inverse gradient but instead approaches
$T_{\textit{bulk}}$
monotonically. To reveal temperature fluctuations at different positions and better understand the characteristics of the boundary layer, we plot the profiles of root-mean-square (RMS) temperature
$\sigma _T$
for six
$Ra$
values in figure 3(b). It can be seen that there is a peak value of
$\sigma _T/\Delta T$
near the bottom wall. The distance between the hot wall and the position of the peak is generally defined as the thickness of the thermal boundary layer (Belmonte, Tilgner & Libchaber Reference Belmonte, Tilgner and Libchaber1994; Wang & Xia Reference Wang and Xia2003; Zhou & Xia Reference Zhou and Xia2013). It is surprising that the temperature fluctuation along the
$z$
direction in figure 3(b) does not continue to decrease gradually after a peak, but rather increases gradually to form a second peak and then decreases to an almost constant value. This feature has not been observed in previous studies and is explored in detail in the following discussions. To verify the reliability of the double-peak feature observed in the
$\sigma _T/\Delta T$
profiles, we also conduct experiments using water in the same set-up. No such double-peak behaviour is observed in the water experiments. Figures 4(a) and 4(b) present a representative condition for liquid metal and water under the same temperature difference of 9.98 K, respectively. In water, the temperature sharply decreases away from the bottom plate and then stabilises near the bulk temperature of the cell, with no inverse temperature gradient observed. Meanwhile,
$\sigma _T / \Delta T$
exhibits a single peak, with the maximum located near the thermal boundary layer. In the same convection cell, the temperature distribution characteristics of liquid metal and water show significant differences. This suggests that the occurrence of the inverse temperature gradient and double-peak feature may be attributed to the extremely low
$\textit{Pr}$
of GaInSn (
$\textit{Pr} = 0.029$
), which is two orders of magnitude lower than that of water.
(a) The profiles of the normalised mean temperature
$\theta$
under six different
$Ra$
. The red solid line represents the result calculated using equation (43) from Shishkina et al. (Reference Shishkina, Horn, Emran and Ching2017), with the coefficients corresponding to the case of
$\textit{Pr} = 0.032$
and
$Ra = 10^7$
. (b) The profiles of the normalised RMS temperature
$\sigma _T/\Delta T$
under the six different
$Ra$
. Here
$z$
is normalised by the height of the cell
$H$
.

Comparison of normalised temperature
$\theta$
and RMS temperature
$\sigma _T/\Delta T$
between liquid metal and water under the same temperature difference of 9.98 K. (a) Liquid metal at
$Ra = 7.20 \times 10^6$
and (b) water at
$Ra = 7.56 \times 10^8$
. The inset shows a logarithmic plot in the range
$0 \leqslant z/H \leqslant 0.3$
.

The commonly accepted explanation for the inverse temperature gradient is the formation of a stable cold-fluid cluster near the centreline, caused by cold fluid descending from the top plate and accumulating in the lower half of the cell (Chu & Goldstein Reference Chu and Goldstein1973; Wan et al. Reference Wan, Wei, Verzicco, Lohse, Ahlers and Stevens2019). Building on the flow structure analysis of Sugiyama et al. (Reference Sugiyama, Ni, Stevens, Chan, Zhou, Xi, Sun, Grossmann, Xia and Lohse2010) in a quasi-two-dimensional cell, it was shown that for low-
$\textit{Pr}$
fluids (
$\textit{Pr} \lt 0.8$
), the large-scale circulation tends to remain in a single-roll state without undergoing reversals. In their supplementary materials, temperature and velocity fields for
$\textit{Pr}=0.7$
illustrate a persistent band of cold fluid extending through the lower half of the cell. By contrast, for water, where reversals occur more often, the flow structures become more complex during these events, leading to strong mixing between hot and cold fluid and preventing the long-lived accumulation of either. This difference in flow organisation is consistent with our experimental observation that the inverse temperature gradient emerges in liquid metals but not in water.
We further calculated the thermal boundary-layer thickness using two different methods: the slope method yields
$\delta _{\textit{th}}$
, while the position of the first peak in the RMS temperature profile gives
$\delta _{\sigma }$
. These results, along with comparisons with previous studies (Naert, Segawa & Sano Reference Naert, Segawa and Sano1997; Scheel, Kim & White Reference Scheel, Kim and White2012; Pandey Reference Pandey2021; Schindler et al. Reference Schindler, Kim, Vogt and Eckert2025), are shown in figure 5. Both the thermal boundary-layer thickness
$\delta _{\textit{th}}$
,
$\delta _{\sigma }$
and the location of the second peak decrease with increasing
$Ra$
, with the scaling of
$\delta _{\textit{th}}/H \approx (2.5642 \pm 0.0154)Ra^{-0.2776 \,\pm\, 0.0331}$
,
$\delta _{\sigma }/H \approx (2.6812 \pm 0.0231)Ra^{-0.2617 \,\pm\, 0.0213}$
and second peak
$/H\approx (3.5564 \pm 0.0443)Ra^{-0.2168 \,\pm\, 0.0186}$
. Our measured boundary-layer thickness shows the closest agreement with the results reported by Scheel et al. (Reference Scheel, Kim and White2012). We also performed detailed measurements of the heat transfer efficiency
$\textit{Nu}$
. Figure 6 shows our measured
$\textit{Nu}$
along with data from previous studies (Takeshita et al. Reference Takeshita, Segawa, Glazier and Sano1996; Cioni, Ciliberto & Sommeria Reference Cioni, Ciliberto and Sommeria1997; Glazier et al. Reference Glazier, Segawa, Naert and Sano1999; Stevens et al. Reference Stevens, van der Poel, Grossmann and Lohse2013; King & Aurnou Reference King and Aurnou2015; Zürner et al. Reference Zürner, Schindler, Vogt, Eckert and Schumacher2019). It can be seen that our results show fairly good agreement with the experimental data from Glazier et al. (Reference Glazier, Segawa, Naert and Sano1999). The scaling relation we obtained is
$\textit{Nu} \approx (0.1589 \pm 0.0151)Ra^{0.2622 \,\pm\, 0.0061}$
, which satisfies the theoretical prediction of
$\textit{Nu} \sim Ra^{1/4}$
in regime
$I_l$
proposed by Grossmann & Lohse (Reference Grossmann and Lohse2000, Reference Grossmann and Lohse2001). The scaling behaviour of
$\textit{Nu}$
is found to be similar to that of
$1/\delta _{\sigma }$
and
$1/\delta _{\textit{th}}$
. Since the thermal boundary layer limits the global heat transport in the cell, the heat transfer efficiency of the system may be expected to exhibit a similar
$Ra$
dependence to that of the boundary-layer thickness. Figure 6 also presents the
$\textit{Nu}$
values estimated from the boundary-layer thicknesses, expressed as
$H/(2\delta _{\sigma })$
and
$H/(2\delta _{\textit{th}})$
. These estimates are higher than the directly measured
$\textit{Nu}$
values. In early experiments using air, Belmonte et al. (Reference Belmonte, Tilgner and Libchaber1994) found that the scaling and magnitude of
$H/(2\delta _{\textit{th}})$
for
$Ra$
are similar to those of the global
$\textit{Nu}$
. However, Lui & Xia (Reference Lui and Xia1998) reported in measurements using water that the thermal boundary-layer thickness measured at the plate centre is insufficient to quantify the global
$\textit{Nu}$
of the cell. Furthermore, in the water measurements by Zhou & Xia (Reference Zhou and Xia2013), significant discrepancies are observed between
$H/(2\delta _{\textit{th}})$
,
$H/(2\delta _{\sigma })$
and
$\textit{Nu}$
. Within the range
$2.6 \times 10^{10} \lt Ra \lt 6.4 \times 10^{11}$
, the average values of
$H/(2\delta _{\textit{th}})$
,
$H/(2\delta _{\sigma })$
and
$\textit{Nu}$
are 416.2, 619.9 and 350.2, respectively.
The measured thermal boundary-layer thickness
$\delta _{\sigma }$
,
$\delta _{\textit{th}}$
and the location of the second peak. Our data are compared with those of previous work, as indicated in the legend. The solid lines represent fitted results. The red solid line corresponds to
$\delta_{(\sigma)} /H \approx (2.6812 \pm 0.0231)Ra^{-0.2617 \,\pm\, 0.0213}$
, the blue solid line to
$\delta _{\textit{th}} /H \approx (2.5642 \pm 0.0154)Ra^{-0.2776 \,\pm\, 0.0331}$
and the black solid line to the dimensionless second peak location by
$H$
$\approx (3.5564 \pm 0.0443)Ra^{-0.2168 \,\pm\, 0.0186}$
. The inset shows a magnified view of
$\delta _{\textit{th}}$
and
$\delta _{\sigma }$
.

Heat transfer in liquid metal convection. The scaling of
$\textit{Nu}$
versus
$Ra$
is shown. Our data are compared with those of previous work, as indicated in the legend. The dashed line represents fitted results.

For a better understanding of the second peak, we extract the temperature information that changed with time at typical locations as shown in figure 7(a). Figure 7(b) presents the temperature time series at a position within the thermal boundary layer, and the dashed line indicates the mean temperature of the bottom plate, which is
$38.18\,^{\circ }\rm C$
. The corresponding probability density function (PDF) is shown in figure 7(c). The red line and vertical red dashed line in the PDF indicate the Gaussian distribution and mean temperature, respectively. The PDF at this position shows that the temperature distribution is approximately Gaussian, which is consistent with the temperature characteristics of water, where the temperature distribution within the boundary layer exhibits a Gaussian distribution (Zhou & Xia Reference Zhou and Xia2013). Figure 7(d) shows the temperature time series near the thermal boundary layer. The corresponding PDF is shown in figure 7(e). Different from the temperature characteristics in the boundary layer, its PDF deviates from a Gaussian distribution with an elevated tail in the range above the mean temperature, which indicates that there is a higher probability of temperatures above the mean temperature. This is believed to be caused by hot plume bursts (Zhou & Xia Reference Zhou and Xia2002; Xi et al. Reference Xi, Zhou, Zhou, Chan and Xia2009). As the temperature probe gradually moves away from the thermal boundary layer, figure 7( f–m) shows that the number of temperature spikes decreases, and they almost disappear near the cell centre. Position (3) in figure 7(a) is between the first and the second peak. The temperature time series and its PDF are shown in figures 7( f) and 7(g). The PDF shows that the temperature recovers a Gaussian distribution. When the temperature probe reaches the second peak position, namely position (4), the temperature PDF in figure 7(i) reveals a peak in the range below the mean temperature, with a probability slightly higher than that of a Gaussian distribution, which indicates a higher probability of detecting fluid with temperatures below the mean at this location. When the probe reaches position (5), figure 7( j) shows that the temperature bursts rarely occur. However, a small number of plumes still pass through the probe, which makes the temperature deviate from the Gaussian distribution. After reaching the centre of the cell, which is location (6), the temperature shows a Gaussian distribution, indicating that the plume is not detected in the cell centre. In water, the temperature at the cell centre also exhibits a Gaussian distribution (Zhou, Sun & Xia Reference Zhou, Sun and Xia2007). In summary, our experimental measurements indicate that there is a certain region where the probability of observing temperatures below the mean is relatively higher.
The time series of temperature at different heights. (a) Profile of the mean temperature
$\overline {T}$
and the degree of temperature fluctuation
$\sigma _T/\Delta T$
measured at
$Ra=4.54\times 10^6$
. The vertical red dashed lines indicate the six selected positions (1)–(6) from which the data in (b–m) are derived. (b) The temperature
$T$
and (c) its PDF for
$z=2.22$
mm
$(0.49\delta _{\textit{th}})$
. The dashed line in (b) is the measured mean temperature of the bottom plate. (d,e) For
$z=4.80$
mm
$(1.08\delta _{\textit{th}})$
; (f,g) for
$z=9.45$
mm
$(2.13\delta _{\textit{th}})$
; (h,i) for
$z=18.33$
mm
$(4.12\delta _{\textit{th}})$
; ( j,k) for
$z=31.58$
mm
$(7.11\delta _{\textit{th}})$
; (l,m) for
$z=63.00$
mm (cell centre).

We further analyse the higher-order characteristics of the temperature distribution, specifically the skewness and flatness. The skewness and flatness are defined as
$T_S=\langle (T-\langle T\rangle ^3)\rangle /{\sigma _T}^3$
and
$T_F=\langle (T-\langle T\rangle ^4)\rangle /{\sigma _T}^4$
. Based on these definitions, a symmetric temperature distribution around its mean corresponds to a skewness value near
$0$
, while a temperature distribution resembling a Gaussian profile exhibits a flatness value approaching
$3$
.
Figure 8 shows the skewness
$T_S$
and flatness
$T_F$
at different positions for the selected three
$Ra$
conditions. Here, the distance
$z$
is non-dimensionalised by the thermal boundary-layer thickness
$\delta _{\textit{th}}$
. According to the skewness and flatness, the positions from the bottom plate to the centre of the cell can be divided into five regions. Region I is inside the boundary layer. The skewness and flatness are at relatively small values, with skewness close to
$0$
and flatness close to
$3$
at the beginning, indicating that the temperature distribution approximates a Gaussian distribution within the boundary layer. However, the closer to the boundary-layer location, the more
$T_S$
and
$T_F$
deviate from
$0$
and
$3$
, and the deviation is the largest for a distance beyond the boundary layer. Region II extends from the boundary layer to the vicinity of the intersection where hot fluid rises and cold fluid descends. Here
$T_S$
and
$T_F$
quickly reach their maximum values, and the temperature distribution’s PDF exhibits higher probability in the range above the mean temperature. Then they start to decrease, entering region III. In this region, the hot and cold fluids mix intensely as they rise and fall, leading to a more symmetric temperature distribution. In region III,
$T_S$
and
$T_F$
decrease to values near
$0$
and
$3$
, respectively, indicating a return to a Gaussian-like distribution. As the probe continues to move upward beyond region III and enters region IV, it detects descending cold fluid. Influenced by the descending cold fluid,
$T_S$
and
$T_F$
rise again, and when they reach their maximum values, they begin to decrease once more. Region V is located near the centre of the cell. At the centre of the cell,
$T_S$
and
$T_F$
decrease to values close to
$0$
and
$3$
, indicating that the centre is rarely affected by the ascending hot fluid or descending cold fluid and that the temperature distribution again approximates a Gaussian distribution. This phenomenon is distinctly different from the results observed in water. In water, the positions from the bottom plate to the centre of the cell can be divided into three regions based on
$T_S$
and
$T_F$
. The first region is within the boundary layer, where
$T_S$
and
$T_F$
are close to
$0$
and
$3$
, respectively. The second region is the central core region, where
$T_S$
and
$T_F$
gradually increase with increasing distance from the bottom plate, reaching their maximum values. The third region is the centre of the cell, where
$T_S$
and
$T_F$
gradually decrease to
$0$
and
$3$
, respectively (Zhou et al. Reference Zhou, Sun and Xia2008, Reference Zhou, Li, Lu and Liu2011; Zhou & Xia Reference Zhou and Xia2013).
Profiles of the skewness
$T_S$
(a) and the flatness
$T_F$
(b) of temperature. Here the vertical distance
$z$
is normalised by the thermal boundary-layer thickness
$\delta _{\sigma }$
. Five different coloured regions divide the lower half of the cell into five zones: region I to region V. The six red vertical dashed lines correspond to the same positions (locations (1)–(6)) as those shown in figure 7 for
$Ra=4.54\times 10^6$
.

To further determine the five regions of temperature distribution in liquid metal, we also use two vertically arranged T-type thermocouples to analyse the delay time and correlation coefficient at different positions. A schematic diagram of the probe is shown in figure 9(a). By placing two temperature probes vertically, one above the other, it is possible to determine the flow direction. If a fluid parcel moves upward, it will first pass the lower probe and then the upper one, resulting in a negative delay time. Conversely, downward motion will produce a positive delay time (Zhou & Xia Reference Zhou and Xia2001). Moreover, this probe arrangement can also be used to identify flow regions. When both probes are located within the same flow region, the temperature signals exhibit high correlation. If the probes are situated in different regions, the correlation will be reduced. The cross-correlation coefficient
$R(z)=C_z(\tau _0)$
is used to characterise the strength of the correlation, where
$C_z(\tau _0)$
is the maximum value of the cross-correlation function. The cross-correlation function is defined as
$C_z(\tau )=\langle \delta T_1(t)\delta T_2(t+\tau )\rangle /[\langle (\delta T_1)^2\rangle \langle (\delta T_2)^2\rangle ]^{1/2}$
, where
$\delta T_1(t)$
and
$\delta T_2(t)$
are the temperature fluctuations at the lower and upper probes, respectively. At each position, we perform a correlation analysis between the temperature time series at two locations. The maximum value of the correlation function is taken as the correlation coefficient
$R$
for that position, and the time lag corresponding to this maximum value is defined as the delay time
$\tau$
.
Correlation analysis of two thermocouples arranged up and down. (a) Schematic of the probe in the flow field. (b) The distribution of the delay time
$\tau$
with position. (c) The distribution of the correlation coefficient
$R$
with position. The region divisions and red vertical dashed lines in (b,c) are the same as those in figure 8.

Plume information obtained from single-thermistor measurements. (a) Method for identifying plumes. (b) Parameters used to characterise plume properties. The distributions of (c) plume number and (d) plume strength, both normalised by their maximum values. The region divisions and red vertical dashed lines in (c,d) are the same as those in figure 9.

Figure 9(b) shows the variation of the delay time
$\tau$
with a position over half the height of the cell. At the bottom plate, the delay time is distinctly negative across different
$Ra$
values, gradually approaching zero as the distance from the bottom plate increases. However, unlike situations in water, where the delay time stabilises near zero and then becomes negative again, the delay time in liquid metal becomes positive after reaching near zero and continues to increase. Negative delay times are caused by the upward movement of tilted plumes, whereas positive delay times correspond to the downward movement of tilted plumes. After reaching a maximum value, the delay time rapidly decreases to around zero because the probe has reached the centre of the cell, where it is difficult to detect plume movement, and the temperature signals from the two probes have almost no time difference. The delay time in region II and region IV exhibits negative and positive values, respectively, indicating the detection of rising hot plumes and descending cold plumes in these regions. In the intermediate region III, the delay time is close to zero, suggesting that the mixing of hot and cold plumes results in a weak vertical velocity in this region. Figure 9(c) shows the corresponding correlation coefficient. When leaving the temperature boundary layer, one probe is inside the boundary layer and the other is outside, so the correlation coefficient first decreases. When both probes are located in the rising thermal plume region (region II), the correlation coefficient increases continuously and reaches its first peak as the upper probe approaches the descending cold plume region (region IV). As the upper probe enters region IV while the lower probe remains outside, the correlation coefficient gradually decreases. Once both probes are located within the descending cold plume region, the correlation begins to rise again and reaches its maximum near the centre of the cell. The spatial distributions of delay time and correlation provide additional evidence for the division of the five regions.
We further differentiate the identified regions based on the statistical characteristics of the thermal plumes. Figure 10 shows the plume information obtained from single-thermistor measurements. When a plume passes through the temperature probe, it causes a fluctuation in temperature, so we extract plume information based on these temperature fluctuations. Figure 10(a) illustrates the process of plume identification. The red dashed line represents the centre value of the temperature PDF, denoted as
$T_{bg}$
. In figure 10(b), the dashed line on the horizontal axis corresponds to
$T_{bg}$
. The blue dashed line in figure 10(a) represents
$T_{bg}$
, where
$\sigma _{bg}$
is the width of the Gaussian distribution, as shown in figure 10(b). Not all temperature fluctuations in figure 10(a) are caused by plumes, so a threshold is set here: temperature fluctuations exceeding
$T_{bg}+\sigma _{bg}$
are recorded as plume fluctuations. The position of the blue triangle in figure 10(a) indicates the peak exceeding
$T_{bg}+\sigma _{bg}$
, which marks the plume’s head. The subsequent temperature trough indicates the plume’s tail, while the preceding temperature trough marks the plume’s front end. The difference between the maximum and minimum temperatures of a plume represents the plume’s strength. Figures 10(c) and 10(d) respectively present the variation of the dimensionless plume number
$P_n$
and plume strength
$P_s$
with position, where
$P_n$
and
$P_s$
are normalised by the maximum value under each condition. It can be observed that both
$P_n$
and
$P_s$
exhibit a double-peak structure. The number of plumes reaches its first peak at the temperature boundary layer (the interface between region I and region II), but the plume strength reaches its first peak near the outside of the boundary layer (region II). The second peaks of both
$P_n$
and
$P_s$
are located within region IV, where prominent plume activity can be detected. In region V near the centre of the cell, both
$P_n$
and
$P_s$
continue to decrease and reach relatively low levels, indicating that plume activity is not significant in the central region of the cell. The analysis of plume characteristics also provides a basis for the division of the five regions.
4. Conclusion
In this work, high-precision thermistors are adopted to measure the temperature distribution along the centreline of a quasi-two-dimensional convection cell filled with liquid metal. Based on the measurements and analysis, several important conclusions can be drawn. Firstly, a clear inverse temperature gradient and double-peak feature in RMS profiles are observed along the half-height of the cell, confirming the presence of distinct thermal regions. The cold fluid detached from the top plate descends along the sidewalls and, upon reaching the lower half of the cell, returns towards the cell centreline, thereby forming a stable cold-fluid region above the bottom plate.
Secondly, the temperature distribution can be divided into five distinct regions: the boundary-layer region, the hot-fluid layer, the hot–cold fluid mixing region, the cold-fluid layer and the bulk region. This division of the lower half of the cell is corroborated by the distribution of the third and fourth moments of temperature, which indicates that the thermal boundary layer exhibits a near-Gaussian distribution with the third and fourth moments close to
$0$
and
$3$
, respectively. The hot-fluid layer shows deviations from this Gaussian distribution, while the hot–cold fluid mixing region exhibits a return to a near-Gaussian distribution. In the cold-fluid layer, the temperature distribution deviates from Gaussian again, but as we move towards the bulk region, the temperature profile gradually returns to a Gaussian distribution.
Finally, the second peak of
$\sigma _T$
can be easily understood based on the division of the flow regions. The first peak in the temperature
$\sigma _T$
appears near the thermal boundary layer due to the influence of plumes detaching from the boundary layer (Belmonte et al. Reference Belmonte, Tilgner and Libchaber1994; Wang & Xia Reference Wang and Xia2003). This second peak is caused by the formation of an independent hot–cold fluid mixing region in the lower or upper half of the cell, where separate areas in hot and cold fluids are present. In moderate- and high-
$\textit{Pr}$
(
$\textit{Pr} \gt 0.8$
) fluids (such as water, air and silicone oil), after detaching from the thermal boundary layer, the hot and cold plumes form a mixing zone, and the plumes gradually dissipate towards the centre of the cell. However, in a quasi-two-dimensional cell, the flow structure of low-
$\textit{Pr}$
fluids significantly differs from that of conventional fluids, leading to a distinct difference in the temperature distribution. The distinct layering observed in the cell underscores the interplay between thermal diffusion and convection in shaping the temperature distribution, offering valuable insights into the heat transfer dynamics in low-
$\textit{Pr}$
fluids.
Funding
This work was supported by the National Natural Science Foundation (NSFC) (grant nos. 52222607, 52176086, 51927812), the National Key R&D Program of China (grant no. 2022YFE03130000) and the Young Talent Support Plan of Xi’an Jiaotong University.
Declaration of interests
The authors report no conflict of interest.





















































