Ossicular chain reconstruction: endoscopic or microscopic?

Published online by Cambridge University Press:  07 January 2021

E A Guneri
Affiliation:
Department of Otorhinolaryngology, Dokuz Eylul University Medical School, Izmir, Turkey
A Cakir Cetin*
Affiliation:
Department of Otorhinolaryngology, Dokuz Eylul University Medical School, Izmir, Turkey
*
Author for correspondence: Dr Asli Cakır Cetın, Department of Otorhinolaryngology, Dokuz Eylul University Medical School, Balcova, Izmir 35340, Turkey E-mail: aslicakir84@hotmail.com Fax: +90 232 4123269
Rights & Permissions [Opens in a new window]

Abstract

Objective

To compare the results of endoscopic and microscopic ossicular chain reconstruction surgery.

Methods

Patients undergoing ossicular chain reconstruction surgery via an endoscopic (n = 31) or microscopic (n = 34) technique were analysed for age, gender, Middle Ear Risk Index, ossicular chain defect, incision type, ossicular chain reconstruction surgery material, mean air conduction threshold, air–bone gap, air–bone gap gain, word recognition score, mean operation duration and mean post-operative follow up.

Results

Post-operative air conduction, air–bone gap and word recognition score improved significantly in both groups (within-subject p < 0.001 for air conduction and air–bone gap, and 0.026 for word recognition score); differences between groups were not significant (between-subject p = 0.192 for air conduction, 0.102 for air–bone gap, and 0.709 for word recognition score). Other parameters were similar between groups, except for incision type. However, endoscopic ossicular chain reconstruction surgery was associated with a significantly shorter operation duration (p < 0.001).

Conclusion

Endoscopic ossicular chain reconstruction surgery can achieve comparable surgical and audiological outcomes to those of microscopic ossicular chain reconstruction surgery in a shorter time.

Information

Type
Main Articles
Copyright
Copyright © JLO (1984) Limited, 2021
Figure 0

Fig. 1. (a) Peri-operative endoscopic view of the discontinuity between the incus (‘i’) and stapes (‘s’). (b) Touching the malleus (‘m’) to confirm the integrity and mobility after the application of bone cement between the incus and stapes.

Figure 1

Fig. 2. (a) Peri-operative endoscopic view of the posteriorly relocated malleus (‘m’). (b) Repair using a titanium total ossicular replacement prosthesis (Grace Medical) with a cartilage footplate shoe.

Figure 2

Fig. 3. (a) Peri-operative endoscopic view of the discontinuity between the incus (‘i’) and stapes (‘s’). (b) Bone cement was applied between the incus, stapes and malleus (‘m’).

Figure 3

Fig. 4. (a) Peri-operative endoscopic view of the absence of stapes in the oval window (‘o’). (b) Placement of autologous malleus graft (‘m’) onto the oval window.

Figure 4

Table 1. Patient characteristics and clinical data

Figure 5

Table 2. Pre-operative air conduction threshold, ABG and WRS, for both groups

Figure 6

Table 3. General linear model of repeated-measures ANOVA

Figure 7

Table 4. ABG gain, ABG closure, and operation and follow-up duration, for both groups

Figure 8

Table 5. Operation duration according to incision type