Effect of skin thickness on electromagnetic dosimetry analysis of a human body model up to 100 GHz

Published online by Cambridge University Press:  06 November 2024

Fatih Kaburcuk*
Affiliation:
Sivas University of Science and Technology, Sivas, Turkey
Rights & Permissions [Opens in a new window]

Abstract

The accuracy of electromagnetic (EM) exposure assessments depends mainly on the resolution of a voxel human body model. The resolution of the conventional human body model is limited to a few millimeters. In the millimeter wave (mmWave) frequency range, EM waves are absorbed by the superficial tissues in the human body. Therefore, resolution and skin thickness of the human body model are important for accuracy of the EM wave exposure metrics recommended by international human safety guidelines. Realistic thickness modeling of the skin tissue on the human body may provide greater accuracy in the EM exposure assessment, especially at mmWave frequency range. In this paper, effects of the skin thickness on the EM exposure metrics in one-dimensional multi-layered models obtained from different regions of the body model are investigated using the dispersive algorithm based on the finite-difference time-domain method over the frequency range from 1 to 100 GHz. Furthermore, effects of eyelid tissue in a human eye on the EM exposure metrics are studied over the frequency range. The EM exposure metrics such as absorbed power density, heating factor, and power transmission coefficient are calculated up to 100 GHz to evaluate the limits of EM wave exposure.

Information

Type
Research Paper
Copyright
© The Author(s), 2024. Published by Cambridge University Press in association with The European Microwave Association.
Figure 0

Table 1. Skin thickness [33] of different regions in the realistic human body

Figure 1

Table 2. Three-term Debye parameters of human tissues from 20 GHz to 100 GHz [37]

Figure 2

Figure 1. (a) 3D human body model [34], (b) 1D multi-layered models shown as dashed lines and derived from 2D cross sectional views (from top to bottom: forehead, eye, chest, forearm, and thigh models).

Figure 3

Table 3. Comparison of maximum local SAR, SAR1g, and SAR10g for the forehead model with IPD of 10 W/m2

Figure 4

Figure 2. APDs of five different models and 1D forearm model presented in [32] when the IPD is 1000 W/m2 for 30 GHz.

Figure 5

Figure 3. Heating factors of the simple 1D model in [23] and 1D models with 2 mm and realistic skin thickness.

Figure 6

Figure 4. APDs of different models with 2 mm and realistic skin thickness for the IPD of 1000 W/m2 at (a) 30 and (b) 60 GHz.

Figure 7

Figure 5. PTCs of the forehead, chest, and thigh 1D models with 2 mm and realistic skin thickness.

Figure 8

Figure 6. PTCs of the open-eye and closed-eye models with 2 mm and 0.57 mm eyelid thicknesses.

Figure 9

Figure 7. Heating factors of the open-eye and closed-eye models with 2 mm and realistic eyelid thicknesses.