Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-06T22:22:57.557Z Has data issue: false hasContentIssue false

GAS ION SOURCE PERFORMANCE OF THE ENVIRONMICADAS AT HEKAL LABORATORY, DEBRECEN, HUNGARY

Published online by Cambridge University Press:  09 March 2021

Mihály Molnár*
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary
Marianna Mészáros
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary
Róbert Janovics
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary
István Major
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary
Katalin Hubay
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary
Botond Buró
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary
Tamás Varga
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary University of Debrecen, Debrecen, H-4001, Hungary
Titanilla Kertész
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary University of Debrecen, Debrecen, H-4001, Hungary
Virág Gergely
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary University of Debrecen, Debrecen, H-4001, Hungary
Ádám Vas
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary University of Debrecen, Debrecen, H-4001, Hungary
Gergely Orsovszki
Affiliation:
Isotoptech Zrt., Debrecen, H-4026, Hungary
Anita Molnár
Affiliation:
Isotoptech Zrt., Debrecen, H-4026, Hungary University of Debrecen, Debrecen, H-4001, Hungary
Mihály Veres
Affiliation:
Isotoptech Zrt., Debrecen, H-4026, Hungary
Martin Seiler
Affiliation:
National Laboratory for Age Determination, NTNU, Trondheim, NO-7491, Norway
Lukas Wacker
Affiliation:
Laboratory for Ion Beam Physics, ETH Zürich, Zürich, CH-8093, Switzerland
A J Timothy Jull
Affiliation:
Isotope Climatology and Environmental Research Centre, Institute for Nuclear Research, Bem tér 18/C, Debrecen, H-4026, Hungary University of Arizona AMS Laboratory, University of Arizona, Tucson, AZ 85721 USA University of Arizona, Department of Geosciences, Tucson, AZ 85721 USA
*
*Corresponding author. Email: molnar.mihaly@atomki.mta.hu.
Rights & Permissions [Opens in a new window]

Abstract

A coupled accelerator mass spectrometer–gas interface system has been successfully operating at the Hertelendi Laboratory of Environmental Studies, Debrecen, Hungary, since 2013. Over the last 6 years more than 500 gas targets were measured below 100 µg carbon content for carbon isotopic composition. The system was tested with blanks, OxII, IAEA-C1, IAEA-C2, and IAEA-C7 standards. The performance of our instrumentation shows good agreement with other published gas-interface system data and also shows a quite good agreement with the nominal value of international standard samples. There is a measurable but quite small memory effect after modern samples, but this does not significantly affect the final results. Typical ion currents at the low energy side were between 10–15 µA with a 5% CO2 in He mixing ratio. The relative errors average ±6% for samples greater than or equal to 10 µgC sample with mean count rates of 300 counts per microgram C for OxII. The blank is comparable with other systems, which is 0.0050 ± 0.0018 F14C or 34,000–47,000 yr BP, which allows for the routine measurement of both of small environmental and archeological samples.

Information

Type
Research Article
Copyright
© The Author(s), 2021. Published by Cambridge University Press for the Arizona Board of Regents on behalf of the University of Arizona
Figure 0

Figure 1 Flow chart and overview of sample types (with number of samples in brackets), applied off-line sample preparation methods, and modes of gas transfer into the Syringe of GIS interface for measurements discussed in this study.

Figure 1

Table 1 Summary of typical gas ion source measurement parameters and settings of EnvironMICADAS and comparison with MICADAS systems at other laboratories.

Figure 2

Figure 2 F14C and δ13C results of OxII tank (n=45) and OxII cracker (n=43) measurements. Open symbols are tank samples, and solid symbols are cracker samples. Solid black lines show the average values, and dashed black lines mark the associated 1σ standard deviations. Dashed red lines represent the nominal values (F14C =1.3407 ± 0.0005 and δ13C = –17.78 ± 0.08‰; Stuiver 1983). (Please see electronic version for color figures.)

Figure 3

Table 2 F14C results of OxII, IAEA standards, and blank CO2 samples, and comparison with nominal values.

Figure 4

Figure 3 Diagram showing the memory effect after measuring three successive blank samples (blank CO2) after a modern sample (OxII). The dark grey bar shows average F14C of 21 OxII samples, and light grey bars show average F14C of 21 blank CO2 samples (6 tank and 15 cracker blanks). Note the 2-magnitude order difference between the two x-axes (i.e., OxII and blank samples). Error bars show 1σ standard deviation.

Figure 5

Figure 4 F14C results of blank CO2 tank samples (n=25). Open symbols are measured values, and solid symbols are values after memory effect correction. Solid black line shows the average F14C (0.0058 ± 0.0022), and dashed black lines mark the associated 1σ standard deviation.

Figure 6

Figure 5 F14C results of blank CO2 cracker samples (n=69). Open symbols are measured values, and solid symbols are values after memory effect correction. Solid black line shows the average F14C (0.0050 ± 0.0018), and dashed black lines mark the associated 1σ standard deviation.

Figure 7

Figure 6 F14C results and constant contamination model of combusted blank samples (n=11). Open symbols mark the measured values, and solid symbols represent the constant contamination corrected values (F14C=0.0000 ± 0.0029). The solid black line shows the best fit and dashed black lines mark the associated 1σ standard deviation. The red line shows the reference value (F14C=0.0000). Error bars mark 1σ uncertainty.

Figure 8

Figure 7 F14C results of IAEA-C1 samples (n=14). Open symbols represent blank corrected values, and solid symbols show blank and memory-effect corrected values. Solid black line shows the average F14C (0.0029 ± 0.0020) and dashed black lines mark the associated 1σ standard deviation. The red line represents the reference value (F14C=0.0000 ± 0.0002; Rozanski 1991). Error bars mark 1σ uncertainty.

Figure 9

Figure 8 F14C results of IAEA-C2 samples (n=11). Open symbols mark blank corrected values. Solid black line shows average F14C (0.4105 ± 0.0049) and dashed black lines mark the associated 1σ standard deviation. Dashed red line represents the reference value (F14C=0.4114 ± 0.0003; Rozanski 1991). Error bars mark 1σ uncertainty.

Figure 10

Figure 9 F14C results of IAEA-C7 samples (n=12). Open symbols show data which were corrected for blank, memory effect and constant contamination, while solid symbols mark values which were corrected only for blank and constant contamination. Solid black line shows average F14C (0.4957 ± 0.0116) and dashed black lines mark the associated 1σ standard deviation. The red line marks the reference value (F14C=0.4953 ± 0.0012; Le Clerq and van der Plicht 1998). Error bars mark 1σ uncertainty.