Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-07T05:19:51.652Z Has data issue: false hasContentIssue false

Psychometric Properties of the NIH Toolbox Cognition Battery in Healthy Older Adults: Reliability, Validity, and Agreement with Standard Neuropsychological Tests

Published online by Cambridge University Press:  01 July 2019

Emmi P. Scott*
Affiliation:
Department of Neurology, Medical University of South Carolina, Charleston, SC 29425, USA
Anne Sorrell
Affiliation:
Appalachian State University, Boone, NC, USA
Andreana Benitez
Affiliation:
Department of Neurology, Medical University of South Carolina, Charleston, SC 29425, USA
*
*Correspondence and reprint requests to: Emmi P. Scott, Department of Neurology, Medical University of South Carolina, 96 Jonathan Lucas Street MSC 323, Charleston, SC 29425, USA. E-mail: scottemm@musc.edu
Rights & Permissions [Opens in a new window]

Abstract

Objective:

Few independent studies have examined the psychometric properties of the NIH Toolbox Cognition Battery (NIHTB-CB) in older adults, despite growing interest in its use for clinical purposes. In this paper we report the test–retest reliability and construct validity of the NIHTB-CB, as well as its agreement or concordance with traditional neuropsychological tests of the same construct to determine whether tests could be used interchangeably.

Methods:

Sixty-one cognitively healthy adults ages 60–80 completed “gold standard” (GS) neuropsychological tests, NIHTB-CB, and brain MRI. Test–retest reliability, convergent/discriminant validity, and agreement statistics were calculated using Pearson’s correlations, concordance correlation coefficients (CCC), and root mean square deviations.

Results:

Test–retest reliability was acceptable (CCC = .73 Fluid; CCC = .85 Crystallized). The NIHTB-CB Fluid Composite correlated significantly with cerebral volumes (r’s = |.35−.41|), and both composites correlated highly with their respective GS composites (r’s = .58−.84), although this was more variable for individual tests. Absolute agreement was generally lower (CCC = .55 Fluid; CCC = .70 Crystallized) due to lower precision in fluid scores and systematic overestimation of crystallized composite scores on the NIHTB-CB.

Conclusions:

These results support the reliability and validity of the NIHTB-CB in healthy older adults and suggest that the fluid composite tests are at least as sensitive as standard neuropsychological tests to medial temporal atrophy and ventricular expansion. However, the NIHTB-CB may generate different estimates of performance and should not be treated as interchangeable with established neuropsychological tests.

Information

Type
Regular Research
Copyright
Copyright © INS. Published by Cambridge University Press, 2019. 
Figure 0

Table 1. NIH toolbox cognition battery tests with corresponding GS tests

Figure 1

Table 2. Sample characteristics at baseline visit

Figure 2

Table 3. Test–retest reliability and practice effects (mean interval 15.03 months, SD = 3.11)

Figure 3

Table 4. Pearson’s correlations between cognitive test scores and cerebral volumes

Figure 4

Table 5. Correlations and agreement between age-adjusted standard scores (M = 100, SD = 15) on NIHTB-CB and GS measures

Figure 5

Fig. 1. Agreement between age-adjusted NIHTB-CB and GS composite scores. (A) Scatter plots with regression lines and shading for 95% CIs of age-adjusted NIHTB and GS crystallized (left) and fluid (right) cognition composite scores. (B) Solid horizontal lines in Bland–Altman plots represent mean differences and upper and lower limits of agreement, illustrating where 95% of differences are expected to fall in the general population. Shading reflects 95% CIs around the mean difference. Dashed lines represent the zero line of perfect agreement. (C) Frequency distributions of discrepancy scores approximate normal distribution.

Supplementary material: File

Scott et al. supplementary material

Scott et al. supplementary material 1

Download Scott et al. supplementary material(File)
File 8 MB