Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-07T12:45:07.116Z Has data issue: false hasContentIssue false

Restenosis after aortic stenting

Published online by Cambridge University Press:  20 January 2005

Joydeep Mookerjee
Affiliation:
Cardiac Unit, Great Ormond Street Hospital for Children, London, UK
Derek Roebuck
Affiliation:
Cardiac Unit, Great Ormond Street Hospital for Children, London, UK
Graham Derrick
Affiliation:
Cardiac Unit, Great Ormond Street Hospital for Children, London, UK
Rights & Permissions [Opens in a new window]

Abstract

Aortic coarctation is a recognized arteriopathy in patients with Williams’ syndrome. We present an adolescent with Williams’ syndrome who developed rapid restenosis after primary stenting of coarctation of the aorta. We believe such restenosis within the stent is due to a proliferative response of the abnormal aortic wall. Attention should be paid to the potential for restenosis during follow-up after stenting of aortic coarctation in patients with Williams’ syndrome.

Information

Type
Brief Report
Copyright
© 2004 Cambridge University Press
Figure 0

The aortogram following stenting of the coarctation (arrow).

Figure 1

The interval aortogram shows reduction of the calibre of the lumen within the stent (arrows).