Hostname: page-component-74656f9884-2dmjx Total loading time: 0 Render date: 2026-11-10T22:48:30.026Z Has data issue: false hasContentIssue false

High-resolution microparticle profiles at NorthGRIP, Greenland: case studies of the calcium–dust relationship

Published online by Cambridge University Press:  14 September 2017

Urs Ruth
Affiliation:
Institut für Umweltphysik, Universität Heidelberg, Im Neuenheimer Feld 299, D-69120 Heidelberg, Germany E-mail: urs.ruth@urz.uni-heidelberg.de Alfred-Wegener-Institut für Polar- und Meeresforschung, Columbusstrasse, D-27568 Bremerhaven, Germany
Dietmar Wagenbach
Affiliation:
Institut für Umweltphysik, Universität Heidelberg, Im Neuenheimer Feld 299, D-69120 Heidelberg, Germany E-mail: urs.ruth@urz.uni-heidelberg.de
Matthias Bigler
Affiliation:
Climate and Environmental Physics, University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland
Jørgen P. Steffensen
Affiliation:
Department of Geophysics, The Niels Bohr Institute for Astronomy, Physics and Geophysics, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen, Denmark
Regine Röthlisberger
Affiliation:
Climate and Environmental Physics, University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland
Heinz Miller
Affiliation:
Alfred-Wegener-Institut für Polar- und Meeresforschung, Columbusstrasse, D-27568 Bremerhaven, Germany
Rights & Permissions [Opens in a new window]

Abstract

A novel flow-through microparticle detector was deployed concurrently with continuous flow analyses of major ions during the North Greenland Icecore Project 2000 field season. the easy-handling detector performs continuous counting and sizing. In this deployment the lower size-detection limit was conservatively set to 1.0 μm equivalent spherical particle diameter, and a depth resolution of ≤1cm was achieved for microparticle concentrations. the dust concentration usually followed the Ca2+ variability. Here results are presented from an inspection of the Ca/dust mass ratio in 23 selected intervals, 1.65 m long each, covering different climatic periods including Holocene and Last Glacial Maximum (LGM). A (Ca2+)/(insoluble dust) mass ratio of 0.29 was found for the Holocene and 0.11 for LGM. Changes to the Ca/dust ratio occur on an annual to multi-annual time-scale exhibiting the same pattern, i.e. a lower Ca/dust ratio for higher crustal concentrations. Moreover, the Ca2+/dust ratio may increase significantly during episodic events such as volcanic horizons due to enhanced dissolution of CaCO3. This calls into question the notion of deploying Ca2+ as a quantitative mineral dust reference species and shows the importance of variable source properties or fractionating processes during transport and deposition.

Information

Type
Research Article
Copyright
Copyright © the Author(s) [year] 2002
Figure 0

Fig. 1 Flow chart of the analytical set-up (highly simplified).

Figure 1

Fig. 2 Detection cell of the laser sensor (schematic).The cross section of the cell is 230 μm×250 μm; the laser beam is 250 μm×1.5 μm wide.

Figure 2

Table 1. Overview of the NorthGRIP core sections used for this study

Figure 3

Fig. 3 Examples of the insoluble dust and the Ca2+ measurements: (a) during the Holocene, (b) during the LGM. Also shown is the Ca2+/dust ratio, which is smoothed (see text). A preliminary estimate of expected annual layer thicknesses λ is included. Note the different scales in all panels for (a) and (b).

Figure 4

Fig. 4 Ca2+/dust ratio and mean dust concentration for all 23 sections plotted against δ18O. Each data point represents a 1.65 m long interval.

Figure 5

Table 2. Mean weight fractions of Ca in different types of crust material (adapted from Bowen, 1978)

Figure 6

Fig. 5 Examples of anomalous events in the microparticle and Ca2+ profiles. the sample is from the cold stadial between interstadials 1 and 2. the data for dust, Ca2+, SO42– and NO3– were obtained by CFA; the Ca2+/dust ratio was smoothed (see text); acidity was measured at approximately 6 cm depth resolution; in the same panel the ECM data are shown in high resolution (preliminary calibration). the fine histogram-style lines represent the high-resolution data reduced to the resolution of the acidity measurement. Labelled Ca2+ peaks refer to events discussed in text.