Preliminary experience with transcatheter closure of wind-sock-like perimembranous ventricular septal defects using Amplatzer Vascular Plug IV devices

Published online by Cambridge University Press:  11 December 2023

Ming Chern Leong*
Affiliation:
Paediatric & Congenital Heart Centre, Institute Jantung Negara (National Heart Institute), Kuala Lumpur, Malaysia
Xin Yi Hoo
Affiliation:
Paediatric & Congenital Heart Centre, Institute Jantung Negara (National Heart Institute), Kuala Lumpur, Malaysia
Mazeni Alwi
Affiliation:
Paediatric & Congenital Heart Centre, Institute Jantung Negara (National Heart Institute), Kuala Lumpur, Malaysia
*
Corresponding author: M. C. Leong; Email: mcleong@ijn.com.my
Rights & Permissions [Opens in a new window]

Abstract

Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.

Information

Type
Brief Report
Copyright
© The Author(s), 2023. Published by Cambridge University Press
Figure 0

Table 1. Summary of the characteristics of the patient and perimembranous ventricular septal defect at the time of intervention

Figure 1

Figure 1. (a) Pre-procedure echocardiogram showing a ventricular septal defect with a windsock morphology which has a small mouth (4.8 mm in diameter) at the left ventricular end and a smaller 3.2 mm right ventricular exit. [Thick arrow]. The tricuspid valve is shown by the thin arrow. (b) Color Doppler image profiling the tricuspid valve aneurysmal sac. (c) Left ventricular angiography showing a perimembranous ventricular septal defect with an aneurysmal tissue which is mildly tortuous. (d) Left ventriculogram showing retrograde device implantation. The device was away from the aortic valve (white line). (e) The left ventricular lobe of the device was minimally protruding into the left ventricle. (f) Transesophageal echocardiogram showing the right ventricular lobe of the device protruding mildly into the right ventricle (*) while the left ventricular outflow tract (#) is not obstructed by the device.

Figure 2

Figure 2. (a) Transesophageal echocardiography revealed a perimembranous ventricular septal defect with the morphology of a long windsock aneurysmal sac. (b) Color-compare image profiling the morphology of the perimembranous ventricular septal defect. (c) The left ventriculogram showed a long, narrowed tunnel aneurysmal sac (arrow). (d) Left ventricular angiography showed the device (arrow) sitting snugly in the sac without tension. (e) Transesophageal echocardiogram in the short axis showing the device in the sac (arrow) without protruding significantly into the right ventricle. (f) Transthoracic echocardiography of the left ventricular outflow tract revealed the left ventricular lobe of the Amplatzer Vascular Plug IV not protruding into the outflow tract.