Hostname: page-component-74656f9884-c52kr Total loading time: 0 Render date: 2026-11-08T08:27:51.541Z Has data issue: false hasContentIssue false

Emission spectra of noble gases and their mixtures under ion beam excitation

Published online by Cambridge University Press:  17 October 2016

M.U. Khasenov*
Affiliation:
National Laboratory Astana, Nazarbayev University, 53 Kabanbay Batyr Avenue, Astana 010000, Kazakhstan
*
Address correspondence and reprint requests to: M.U. Khasenov, National Laboratory Astana, Nazarbayev University, 53, Kabanbay Batyr Avenue, NLA, Astana 010000, Kazakhstan. E-mail: mendykhan.khassenov@nu.edu.kz

Abstract

The luminescence spectra of noble gases and their binary mixtures were measured using heavy ion beam excitation from a DC-60 accelerator. Spectra were measured in the range of 200–975 nm; the gas spectra were dominated by lines of p–s and d–p atomic transitions; in neon and argon, lines from atomic oxygen, N2, N2 +, and OH radical bands were also observed. The ultraviolet region of the spectra was represented by a “third continuum” of noble gases. In krypton, the band of the KrO excimer molecule with a maximum at 557 nm was also observed. The maxima of the heteronuclear ionic molecules bands were located at wavelengths of 329 and 506 nm (Ar–Xe), 491 nm (Kr–Xe), and 642 nm (Ar–Kr). The relative intensities of the 2p–1s transitions of the noble gases atoms were measured and are discussed.

Information

Type
Research Article
Copyright
Copyright © Cambridge University Press 2016 
Figure 0

Fig. 1. Schematic representation of the installation: flange with Ti foil (1); irradiation chamber (2); pressure gauge (3); pressure controller (4); quartz window (5); collimator (6); fiber (7); spectrometer (8); PC (9); gas inlet valve (10).

Figure 1

Fig. 2. Spectra of Ar(79.6 kPa), Kr(80.6 kPa), and Xe(30.7 kPa) under argon beam excitation in the range of 200–600 nm. Integration time of the spectrometer: 3s.

Figure 2

Fig. 3. Spectra of Ar(59.3 kPa)–Xe(6.7 kPa), Kr(53.3 kPa)–Xe(13.6 kPa) and Ar(53 kPa)–Kr(13.6 kPa) mixtures under argon beam excitation in the range of 300–650 nm. Integration time of spectrometer: 3s (Kr–Xe, Ar–Kr) and 1s (Ar–Xe).

Figure 3

Fig. 4. Spectra of Kr–Xe under argon beam excitation in the range of 420–570 nm, a partial pressure of Kr of 53.3 kPa (1, 3) and 52 kPa (2) and a partial pressure of Xe of 0.67 kPa (1), 1.5 kPa (2), and 13.6 kPa (3).

Figure 4

Fig. 5. Spectra of Ar(66.6 kPa) and Ar(65.3 kPa)–Xe(0.67) in the range of 650–975 nm. BK-7 glass lens.

Figure 5

Table 1. The intensity lines of the 2p–1s transitions of argon (79.6 kPa) and neon (80 kPa) excited by argon ions (relative units, corrected for the spectral sensitivity of the installation)

Figure 6

Fig. 6. Spectra of Kr(53.3 kPa) and Kr(52.6 kPa)–Xe(0.67 kPa) in the range of 750–930 nm. Integration time of spectrometer: 1s.

Figure 7

Table 2. The intensity lines of the 2p–1s transitions of krypton (80.6 kPa), xenon (30.7 kPa), and the lines of xenon in the Kr(52.6 kPa)–Xe(0.67 kPa) and Ar(65.3 kPa)–Xe(0.67 kPa) mixtures excited by argon ions (corrected relative units)

Figure 8

Table 3. Emission intensity distribution (in percentage) on the 2p levels of Xe in the xenon (30.7 kPa), Kr(52.6 kPa)–Xe(0.67 kPa), Ar(65.3 kPa)–Xe(0.67 kPa) mixtures, and 2p levels of Kr in the krypton(80.6 kPa) and Ar(59.3 kPa)–Kr(0.67 kPa) mixture