Hostname: page-component-6898cfcb55-th4rj Total loading time: 0 Render date: 2026-11-11T18:28:43.887Z Has data issue: false hasContentIssue false

Melt-layer thickness measurements during crushing experiments on fresh-water ice

Published online by Cambridge University Press:  20 January 2017

R.E. Gagnon*
Affiliation:
Institute for Marine Dynamics, Motional Research Council of Canada, St. John’s, Newfoundland A1B 3T5, Canada
Rights & Permissions [Opens in a new window]

Abstract

A stainless-steel platen, with a centrally located pressure sensor on the front face, has been used to crush mono-crystalline, bubble-free fresh-water ice samples. Two electrical conductors, located on the face of the pressure sensor, were connected to a bridge circuit so that the presence of liquid between the two conductors could be detected and its thickness measured. Video records of the ice/ steel contact zone during crushing were obtained by mounting samples on a thick Plexiglas plate which permitted viewing through the specimen to the ice/steel interface. Total load and pressure records exhibited a sawtooth pattern due to the compliance of the ice and the testing apparatus, and spalling of ice from the contact zone. When the region of contact was in the vicinity of the pressure transducer, liquid was detected and peaks occurred in the liquid sensor output when load drops occurred. Contact between the platen and the ice consisted of low pressure zones of highly damaged crushed and/or refrozen ice, opaque in appearance, and transparent, high-pressure regions of relatively undamaged ice. Upper limits for the liquid-layer thickness on the high-pressure undamaged ice were ~3 µm on the ascending sides of the sawteeth in the load records and ~ 21 µ on the sharp descending sides.

Information

Type
Research Article
Copyright
Copyright © International Glaciological Society 1994
Figure 0

Fig. 1.Crushing apparatus with mirror for viewing the contact zone during experiments.

Figure 1

Fig. 2.Schematic of the liquid sensor and pressure transducer.

Figure 2

Fig. 3.Calibration data used to convert the output from the liquid sensor to layer thicknesses.

Figure 3

Fig. 4.Load, pressure and liquid-sensor records for a typical test run at &-10°C with a nominal actuator speed of 0.5 cm s-1.

Figure 4

Fig. 5.Sections of the load, pressure and liquid-sensor records, on an expanded scale, for the test shown in Figure 4.

Figure 5

Fig. 6.Video frame showing the platen/ice contact zone during a crushing test. The transparent undamaged zone (A), which covers a fraction of the pressure-sensor piston (B) and marginally encompasses the liquid sensor (C), bears approximately 88% of the load. It is surrounded by opaque material (D) consuting of small ice particles and partially refrozen extruded material from the high-pressure zone. The bright region in the upper righthand corner is light refecting internally from the sloping surface of the specimen.

Figure 6

Fig. 7.Schematic of the process of pressure melting and viscous flow of melt which occurs when the ice moves against the platen. The relative velocity of the ice towards the platen is ∼0.14 cm s−1 on the ascending side of a sawtooth and ∼26cm s−1 on the descending side at a load drop. The fluid-layer thickness is on the order of μm.

Figure 7

Fig. 8.Schematic of the spalling process that occurs at a load drop.

Figure 8

Fig. 9.Section of the time series of the relative displacement of the ice against the crushing platen, and corresponding load for the test shown in Figure 4. The time segment is the same as that in Figure 5. The relative displacement was determined from the nominal actuator speed, the load data and the known compliance of the ice/ apparatus system. For the purpose of presentation, the load record has been filtered to diminish resonance.

Figure 9

Table 1.Layer-thickness measurements from the liquid sensor