Transcatheter closure of large perimembranous ventricular septal defects with inlet to outlet extension with the Amplatzer Vascular Plug-II

Published online by Cambridge University Press:  05 December 2022

Enrico Piccinelli
Affiliation:
Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, UKNational Heart and Lung Institute, Imperial College London, UKPolito BIO Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Italy
Carles Bautista-Rodriguez
Affiliation:
Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, UKNational Heart and Lung Institute, Imperial College London, UK
Alain Fraisse*
Affiliation:
Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, UKNational Heart and Lung Institute, Imperial College London, UK
*
Author for correspondence: Alain Fraisse, Paediatric Cardiology Services, Royal Brompton Hospital and Harefield NHS Foundation Trust, Sydney Street, SW3 6NP London, UK. Tel: +442073528121 ext 88680. E-mail: a.fraisse@rbht.nhs.uk
Rights & Permissions [Opens in a new window]

Abstract

Transcatheter closure of perimembranous ventricular septal defect is an alternative to surgery in selected small to medium defects with a reasonable distance between the defect and the aortic or tricuspid valves. Surgical closure is generally preferred for large defects with an inlet to outlet extension, aortic malalignment, or deficient aortic rim. We report two successful cases of percutaneous closure of large perimembranous ventricular septal defects with inlet to outlet extension using an Amplatzer Vascular Plug-II via a retrograde approach. Transcatheter closure of large perimembranous ventricular septal defect with inlet to outlet extension is feasible and facilitated by the characteristics of the Amplatzer Vascular Plug-II device and the specific implantation technique.

Information

Type
Brief Report
Copyright
© Royal Brompton hospital, 2022. Published by Cambridge University Press
Figure 0

Figure 1.(a) Transesophageal echocardiogram demonstrates a 10 mm large perimembranous ventricular septal defect with significant malalignment of the ventricular septum and no aortic rim. In (b) and (c), there is accessory tricuspid valve tissue (white star) and inlet extension, with no rim toward the septal leaflet of the tricuspid valve, with large left to right shunt. In (d), a left ventricular angiogram confirmed a large perimembranous ventricular septal defect measured at 10 mm (black arrow). Ao = Aorta; LV = Left ventricle; RV = Right ventricle; RA = Right atrium; LA = Left atrium.

Figure 1

Figure 2.(a) A 0.035'' Terumo guidewire over a 4Fr multipurpose catheter was easily advanced across the defect into the right pulmonary artery. In (b), transesophageal echocardiogram short-axis view confirmed the outlet extension of the defect. AoV = Aortic valve; RV = Right ventricle.

Figure 2

Figure 3.(a) A 12 mm AVP-II device was successfully positioned and released. In (b) and (c), transthoracic echocardiogram showed almost no residual shunt and normal opening of the tricuspid valve despite the protrusion of the AVP-II on the RV side. AVP-II = Amplatzer Vascular Plug-II; AoV = Aortic Valve; LV = Left ventricle; RV = Right ventricle; RA = Right atrium; LA = Left atrium.

Figure 3

Figure 4.(a) shows severely dilated left atrium and left ventricle on transthoracic echocardiogram. In (b), (c), and (d), transthoracic and transesophageal echocardiogram demonstrated a large perimembranous ventricular septal defect (16 mm) with inlet (white star) to outlet extension (white arrow showing the pulmonary valve), malalignment of the ventricular septum, and almost no aortic rim as well as no rim towards the septal leaflet of the tricuspid valve, with large left to right shunt. Ao = Aorta; LV = Left ventricle; RV = Right ventricle; RA = Right atrium; LA = Left atrium.

Figure 4

Figure 5.An 18 mm AVP-II device was successfully implanted with excellent result and no residual shunt. AVP-II = Amplatzer Vascular Plug-II; LV = Left ventricle; RV = Right ventricle; RA = Right atrium; LA = Left atrium.