Hostname: page-component-74656f9884-j7cmm Total loading time: 0 Render date: 2026-11-09T13:32:55.655Z Has data issue: false hasContentIssue false

Experimental sensitivity analysis and control of thermoacoustic systems

Published online by Cambridge University Press:  16 December 2015

Georgios Rigas*
Affiliation:
Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
Nicholas P. Jamieson
Affiliation:
Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
Larry K. B. Li
Affiliation:
Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
Matthew P. Juniper
Affiliation:
Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ, UK
*
†Email address for correspondence: gr379@cam.ac.uk

Abstract

In this paper, we report the results of an experimental sensitivity analysis on a thermoacoustic system – an electrically heated Rijke tube. We measure the change of the linear stability characteristics of the system, quantified as shifts in the growth rate and oscillation frequency, that is caused by the introduction of a passive control device. The control device is a mesh, which causes drag in the system. The rate of growth is slow, so the growth rate and frequency can be measured very accurately over many hundreds of cycles in the linear regime with and without control. These measurements agree qualitatively well with the theoretical predictions from adjoint-based methods of Magri & Juniper (J. Fluid Mech., vol. 719, 2013, pp. 183–202). This agreement supports the use of adjoint methods for the development and implementation of control strategies for more complex thermoacoustic systems.

Information

Type
Rapids
Copyright
© 2015 Cambridge University Press 
Figure 0

Figure 1. Rijke tube layout and notation. Thermoacoustic oscillations can be excited because acoustic velocity fluctuations cause heat release fluctuations at the primary electrical heater. If the primary heater is in the upstream half of the tube then higher heat release is sufficiently in phase with higher pressure that thermal energy is converted to acoustic energy over a cycle, making the system unstable. A mesh is used as a passive control device here, which causes drag in the system.

Figure 1

Figure 2. Bifurcation diagram obtained experimentally in the Rijke tube. The system becomes unstable through a subcritical Hopf bifurcation. The forward path (right-pointing triangles) shows the position of the Hopf point, and the backward path (left-pointing triangles) shows the position of the fold point.

Figure 2

Figure 3. (a,b) Transient pressure signals obtained by applying step changes to the heater power input. (a) Growth, from $P_{H}-{\it\epsilon}$ to $P=223$ W. (b) Decay, from $P_{F}+{\it\epsilon}$ to $P=140$ W.(c,d) Amplitude of the filtered pressure signals obtained from the Hilbert transform. The linear growth (c) and linear decay (d) regions are represented by the red lines fitted between the noise floor and the point where nonlinear effects become important.

Figure 3

Figure 4. Linear stability characteristics for the baseline case as a function of the primary heater power: (a) growth/decay rate, ${\it\sigma}_{r}$; (b) frequency, ${\it\sigma}_{i}$. Experimental data (symbols) and linear fit (red line).

Figure 4

Figure 5. Stability regions as a function of the position of the drag device. Forward-path critical powers: Hopf points (squares); backward-path critical powers: fold points (circles). A bistable region exists between the two lines.

Figure 5

Figure 6. (a) Growth rates and (b) decay rates, ${\it\sigma}_{r,c}$, obtained with the control drag device positioned at $x_{c}/L=0.4$. Each curve represents the amplitude response for a different departure size above or below the Hopf or fold point.

Figure 6

Figure 7. (a) Growth rate and (b) shift in growth rate obtained experimentally as a function of power supplied to the heater and position of the drag device. Forward-path critical powers: squares; backward-path critical powers: circles. The primary heater was located at $x_{c}/L=0.25$.

Figure 7

Figure 8. Sensitivity of the growth rate to a drag device. (a) Experimental results and (b) theoretical predictions by Magri & Juniper (2013). Each experimental curve corresponds to a different primary heater power; the average sensitivity is also shown (solid circles).

Figure 8

Figure 9. (a) Frequency and (b) frequency shift obtained experimentally as a function of power supplied to the heater and the position of the drag device. Forward-path critical powers: squares; backward-path critical powers: circles.

Figure 9

Figure 10. (a) Sensitivity of the frequency to a drag device. Experimental results for various primary heater powers: open circles; average: solid circles. (b) An estimate of the frequency change (solid triangles) due to variations in the outlet temperature.