Otoendoscopy as a better preoperative predictor than pure tone audiometry for ossicular erosion in mucosal chronic otitis media

Published online by Cambridge University Press:  01 May 2024

Abhishek Bhardwaj
Affiliation:
Department of Otorhinolaryngology & Head-Neck Surgery, All India Institute of Medical Sciences, Rishikesh, India
Kartikesh Gupta
Affiliation:
Department of Otorhinolaryngology & Head-Neck Surgery, All India Institute of Medical Sciences, Rishikesh, India
Suji PS
Affiliation:
Department of Otorhinolaryngology & Head-Neck Surgery, All India Institute of Medical Sciences, Rishikesh, India
Manu Malhotra*
Affiliation:
Department of Otorhinolaryngology & Head-Neck Surgery, All India Institute of Medical Sciences, Rishikesh, India
Madhu Priya
Affiliation:
Department of Otorhinolaryngology & Head-Neck Surgery, All India Institute of Medical Sciences, Rishikesh, India
Saurabh Varshney
Affiliation:
All India Institute of Medical Sciences, Deoghar, Jharkhand, India
Rachit Sood
Affiliation:
Department of Otorhinolaryngology & Head-Neck Surgery, All India Institute of Medical Sciences, Rishikesh, India
Arpana Singh
Affiliation:
Department of Microbiology, All India Institute of Medical Sciences, Rishikesh, India
*
Corresponding author: Manu Malhotra; Email: manumalhotrallrm@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

Objective

To compare the diagnostic accuracy of angled otoendoscopy with pure tone audiometry in predicting ossicular discontinuity in patients of mucosal chronic otitis media.

Methods

Ninety-four patients were included in this prospective study. A 2.7-mm 30° otoendoscope was used to examine ossicular status preoperatively. Hearing thresholds were recorded by pure tone audiometry. Intraoperative ossicular status was recorded as the gold standard. Otoendoscopic findings were recorded as per the criteria has been devised by the authors of this manuscript.

Results

Otoendoscopy was conclusive in 56 (59.6 per cent) patients, with 100 per cent sensitivity, 95.56 per cent specificity, 84.62 per cent positive predictive value, and 100 per cent negative predictive value in the conclusive group. Overall (in 94 patients), diagnostic test values of otoendoscopy were 73.33 per cent sensitivity, 97.47 per cent specificity, 84.62 per cent positive predictive value, and 95.06 per cent negative predictive value. As per the ROC curve, air–bone gap > 38.12dB had the optimal diagnostic test values, with 73 per cent sensitivity, 72 per cent specificity, 33.3 per cent positive predictive value, and 93.4 per cent negative predictive value.

Conclusion

Angled otoendoscopy has better diagnostic accuracy (93.6 per cent) than pure tone audiometry (72.3 per cent; p < 0.001) for preoperative ossicular discontinuity prediction in patients of mucosal chronic otitis media.

Information

Type
Main Article
Copyright
Copyright © The Author(s), 2024. Published by Cambridge University Press on behalf of J.L.O. (1984) LIMITED
Figure 0

Table 1. Criteria to record ossicular status on endoscopy; IS = incudostapedial; OD = ossicular discontinuity: OD+ = patients with ossicular discontinuity; OD− = patients without ossicular discontinuity

Figure 1

Table 2. Comparison of endoscopic assessment (as a test) with intra-operative assessment as the gold standard; OD = ossicular discontinuity: a = OD absent as per endoscopic assessment; b = endoscopic assessment non-conclusive

Figure 2

Table 3. Diagnostic test values of otoendoscopy; CI = confidence interval; LR = likelihood ratio

Figure 3

Table 4. Diagnostic test values at different ABG (air–bone gap) thresholds; CI = confidence interval; LR = likelihood ratio; negative predictive value = negative predictive value; PPV = positive predictive value

Figure 4

Figure 1. Otoendoscopy images as per the descriptions given in Table 1.

Figure 5

Figure 2. Receiver-operating characteristic (ROC) curve for different pure tone audiometry averages in predicting ossicular discontinuity. Diagonal segments are produced by ties. ABG = air–bone gap; AC = air-conduction threshold; PTA = pure tone audiometry; S.E. = standard error.