Hostname: page-component-74656f9884-qr5l4 Total loading time: 0 Render date: 2026-11-03T18:26:54.524Z Has data issue: false hasContentIssue false

Nonlinear dynamics in dusty plasmas subjected to photo-discharging

Published online by Cambridge University Press:  19 December 2024

Michael McKinlay*
Affiliation:
Department of Physics and Astronomy, Ball State University, Muncie, IN 47306, USA
Edward Thomas Jr
Affiliation:
Physics Department, Auburn University, Auburn, AL 39849, USA
Saikat Chakraborty Thakur
Affiliation:
Physics Department, Auburn University, Auburn, AL 39849, USA
*
†Email address for correspondence: michael.mckinlay@bsu.edu

Abstract

Experimental research into the control of particle charge in dusty plasmas conducted at Auburn University indicates that photocurrents generated by exposing dust to intense, near-ultraviolet light can provide a reliable and novel method of independently controlling dust charge without radically altering the background plasma; the experiment also showed that some particles may respond differently to this photo-discharge, with some exhibiting highly periodic responses to the discharge and others exhibiting chaotic behaviour. Since the dust particles in the experiment were a polydisperse sample of different sizes and shapes, particle geometry may play a role in explaining this difference. Simulations of particle discharge and dynamics are used in an attempt to reproduce experimental results and investigate a possible correlation between particle symmetry and dynamic periodicity.

Information

Type
Research Article
Copyright
Copyright © The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. A schematic of the Auburn DPX apparatus during the photo-discharging experiment. The primary chamber (left) contains a plasma generating anode (disk) connected to a high voltage, current-limited power supply; a confining electrode (ring) connected to a low-voltage DC bias; and a tray containing the dust sample. The secondary chamber (right) provides access to a vacuum pump and argon gas via a mass flow controller. Windows on the sides and front provide access to optical equipment.

Figure 1

Figure 2. (a) Samples of the lanthanum hexaboride (LaB$_6$) particles used in the experiment, imaged by an SEM. The particles have a wide distribution of sizes and shapes compared with particles used in typical laboratory experiments. (b) A dust particle undergoing periodic displacement in response to pulses of NUV light during the photo-discharging experiment. The image shows the overlay of $\sim$20 seconds of video frames, or $\sim$19 complete pulses (McKinlay & Thomas 2021).

Figure 2

Figure 3. (a,b) Vertical positions of two example particles from the photo-discharging experiment as a function of pulse-time (with the pulse turning on at 0.0 s and off at 0.5 s). One particle in panels (a,c) exhibits periodic motion, while another in panels (b,d) exhibits more chaotic motion. (c,d) Same behaviour plotted in the velocity versus position phase space. Each plot contains data from 19 complete pulses. The colour and brightness of the data are used to show the passage of time (as indicated by the bar at the top of each figure); becoming darker with each pulse.

Figure 3

Figure 4. An illustration of how particle geometry may affect photo-discharging. The highly symmetric spherical particle in panel (a) will have the same cross-sectional area, and thus the same photocurrent, for a light pulse of a given intensity, while the ellipsoidal particle in panel (b) has a cross-section (and thus photocurrent) which may change as it rotates.

Figure 4

Figure 5. Simulated surfaces or ‘hulls’ of four example particles: a sphere (a), a prolate spheroid (b), an oblate spheroid (c) and a scalene ellipsoid (d). The lighter violet colouring indicates the region of the particle surface illuminated by a simulated parallel light source pointing from the left (as viewed here). While half of the surface area of these regular, convex particles is always illuminated by the pulse, the cross-section of those particles which are more elongated or flattened will change with their orientation.

Figure 5

Table 1. Axial lengths (in $\mathrm {\mu }$m) and $\kappa$-values for the example particles in figure 5. A $\kappa$-value of 0 indicates symmetry about an axis, while positive and negative values indicate stretching or compression along an axis, respectively. These particles were among those simulated and are discussed later as part of the simulation results.

Figure 6

Table 2. Coefficients for the functional forms of the floating potential (in V), ion density (in $10^{15}\,{\rm m}^{-3}$) and electron temperature (in eV) shown in (2.19), (2.20) and (2.21), after being fitted to data from the Langmuir probes. All coefficients shown above assume a vertical position, $z$, measured in cm.

Figure 7

Figure 6. Plots of the Langmuir probe data and (a) fits of the floating potential, (b) ion density and (c) electron temperature from the photo-discharging experiment. To match the simulation as closely to the experiment as possible, the same functions fitted to the Langmuir probe data from the experiment were used as the plasma profiles for the simulation.

Figure 8

Figure 7. Distribution of dust sizes for the particles in the experiment and the simulation and the overlap between distributions. (a) Distribution of all the measured and simulated axial diameters. The mean axial diameter of dust in the experiment was $10.77\pm 5.42\,\mathrm {\mu }$m, while the mean axial diameter of the simulated particles was $14.56\pm 8.02\,\mathrm {\mu }$m. (b) Distribution of the effective diameters of the real and simulated particles; defined here as the geometric mean of axial diameters (the diameter of a spherical particle with an equivalent cross-section or volume). The mean effective diameter of the particles was $10.45\pm 4.66\,\mathrm {\mu }$m in the experiment compared with $13.41\pm 5.93\,\mathrm {\mu }$m in the simulation.

Figure 9

Figure 8. Vertical position of the particles from figure 5 – the sphere (a), prolate (b) and oblate (c) spheroids, and the scalene ellipsoid (d) – over the course of each simulated pulse (with the pulse turning on at 0.0 s, and off at 0.5 s). The colour and brightness are used to indicate the passage of time, with the data for each pulse growing steadily darker. The motion of the spherical particle is virtually identical for each pulse, while the motions of the less symmetric particles diverge.

Figure 10

Figure 9. Motion of the particles from figure 5 in phase space. The colour and brightness of the data are used to indicate the passage of time, with each pulse growing darker. The orbits of the sphere in panel (a) are closed and nearly identical; those of the spheroids in panels (b,c) are closed or nearly closed, but with moderate variation; and those of the scalene ellipsoid in panel (d) are slightly open and extremely varied.

Figure 11

Table 3. Values of $\delta _A$ and SNR for the four simulated ellipsoids described in figure 9, and the two particles from the experiment described in figure 3, ordered from most periodic to least.

Figure 12

Figure 10. Simulated particles viewed in (a) the real-space determined by the axial lengths of the ellipsoids and (b) the logarithmic $\kappa$-space. The transformation to $\kappa$-space projects the particles into a plane, which preserves information about particle shape at the expense of information about the physical scale. The colour and brightness of the points indicate the value of $\delta _A$, with lighter points corresponding to more periodic motion and darker points to more chaotic motion. (c,d) Same as panels (a,b) when looking ‘down’ through the centre of the panels (along the line defining spherical particles). The three axes in the $\kappa$-space in panel (d) define prolate spheroids, with each tick indicating a factor of $\kappa _0$.

Figure 13

Figure 11. (a) Results for $\delta _A$ and (b) the signal-to-noise ratio averaged over a grid of interrogation cells in $\kappa$-space (note that this is the same data as figure 10, just looking out away from the $\kappa$ plane instead of down towards it). In both panels, colour and shading are used to indicate periodicity, with lighter colours corresponding to more periodic behaviour and darker colours to more chaotic behaviour. Regions where $\delta _A$ exceeds unity are coloured black in both panels. The highest periodicity is located at the origin, with behaviour becoming less periodic and more chaotic as particles move away from the centre, and towards more scalene and oblate particles. The rings indicate circles of constant-$|\kappa |$ ($\kappa _0$, 2$\kappa _0$ and 3$\kappa _0$).

Figure 14

Table 4. Descriptions of behavioural regimes of simulated particle motion correlated with approximate ranges of SNR. Behaviour becomes more periodic as SNR increases and more chaotic as it decreases. Strongly periodic behaviour describes cases where ${\rm SNR} \gtrsim 3$. Strongly chaotic behaviour describes cases where SNR drops below 0 (regions where $\delta _A$ is over unity).

Figure 15

Figure 12. Same data as figure 11, but divided into the behavioural regimes described in table 4: strongly periodic (SP) behaviour is limited to spherical particles at the centre of the grid; weakly periodic (WP) behaviour is mostly confined to within a radius of ${\sim }\kappa _0$ from the centre and appears to indicate a slight preference towards prolate particles; weakly chaotic (WC) behaviour dominates the region between $\sim 1$ and $2\kappa _0$; strongly chaotic (SC) behaviour seems to be limited to particles beyond $\sim 2\kappa _0$. A slight asymmetry can be seen along the $\hat {\kappa }_{yz}$-axis; this asymmetry may be the result of an oversampling of spheroidal particles along this axis.