Hostname: page-component-74656f9884-8r8nv Total loading time: 0 Render date: 2026-11-08T12:30:22.336Z Has data issue: false hasContentIssue false

Cyclotron auto resonance maser and free electron laser devices: a unified point of view

Published online by Cambridge University Press:  09 January 2017

E. Di Palma*
Affiliation:
ENEA – Frascati Research Center, Via Enrico Fermi 45, 00044, Frascati, Rome, Italy
E. Sabia
Affiliation:
ENEA – Frascati Research Center, Via Enrico Fermi 45, 00044, Frascati, Rome, Italy
G. Dattoli
Affiliation:
ENEA – Frascati Research Center, Via Enrico Fermi 45, 00044, Frascati, Rome, Italy
S. Licciardi
Affiliation:
University of Catania, Department of Mathematics, Via Santa Sofia, 64, 95125 Catania, Italy
I. Spassovsky
Affiliation:
ENEA – Frascati Research Center, Via Enrico Fermi 45, 00044, Frascati, Rome, Italy
*
†Email address for correspondence: emanuele.dipalma@enea.it
Rights & Permissions [Opens in a new window]

Abstract

We take advantage of previous research in the field of cyclotron auto resonance maser (CARM) and undulator-based free electron laser (U-FEL) sources to establish a common formalism for the relevant description of the underlying physical mechanisms. This strategy is aimed at stressing the deep analogies between the two devices and at providing a practical tool for their study based on the use of well-tested scaling formulae developed independently for the two systems.

Information

Type
Research Article
Copyright
© Cambridge University Press 2017 
Figure 0

Figure 1. Comparison between U-FEL (blue) and CARM (green) intensity growth curves in a small signal regime with the result reported in Chen & Wurtele (1991).

Figure 1

Figure 2. Small signal CARM growing intensity, with and without the imaginary contributions from (2.4).

Figure 2

Figure 3. Transverse mode pattern and associated gain length. The circle in the middle represents the electron beam transverse distribution, which is assumed to stay well inside the mode itself thus maximizing the filling factor.

Figure 3

Figure 4. The revisited semi-analytical formula from FEL compared with numerical code.

Figure 4

Figure 5. The analytical growth linear rate of the signal compared with the numerical simulation.

Figure 5

Figure 6. Efficiency behaviour (for optimal detuning $\unicode[STIX]{x1D6E5}$) versus transverse velocity spreadfor different values of $I_{g}$ (dotted line numerical computation, red line Lorentzian fit).