Hostname: page-component-7b7567c8c-fvjsw Total loading time: 0 Render date: 2026-11-15T22:38:14.617Z Has data issue: false hasContentIssue false

A dynamic flow model mimicking duodenoscope reprocessing after bacterial contamination for translational research

Published online by Cambridge University Press:  13 September 2022

Maarten Heuvelmans*
Affiliation:
Department of Medical Microbiology, University Medical Center Utrecht, Utrecht, The Netherlands
Willem Woudstra
Affiliation:
Department of Biomedical Engineering, University of Groningen, Groningen, The Netherlands
Herman F. Wunderink
Affiliation:
Department of Medical Microbiology, University Medical Center Utrecht, Utrecht, The Netherlands
Jan F. Monkelbaan
Affiliation:
Department of Gastroenterology and Hepatology, University Medical Center Utrecht, Utrecht, The Netherlands
Henny C. van der Mei
Affiliation:
Department of Biomedical Engineering, University of Groningen, Groningen, The Netherlands
*
Author for correspondence: Maarten Heuvelmans, Department of Medical Microbiology G04.643, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands. E-mail: M.Heuvelmans-17@umcutrecht.nl

Abstract

Objective:

Duodenoscopy-associated infections and outbreaks are reported globally despite strict adherence to duodenoscope reprocessing protocols. Therefore, new developments in the reprocessing procedure are needed.

Design:

We evaluated a novel dynamic flow model for an additional cleaning step between precleaning and manual cleaning in the reprocessing procedure.

Methods:

A parallel plate flow chamber with a fluorinated ethylene propylene bottom plate was used to mimic the duodenoscope channels. The flow chamber was inoculated with a suspension containing Klebsiella pneumoniae to simulate bacterial contamination during a duodenoscopic procedure. After inoculation the flow chamber was flushed with a detergent mimicking precleaning. Subsequently the flow chamber was subjected to different interventions: flow with phosphate-buffered saline (PBS), flow with 2 commercial detergents, flow with sodium dodecyl sulfate with 3 different concentrations, and flow with microbubbles. Adhering bacteria were counted using phase-contrast microscopy throughout the experiment, and finally, bacterial viability was assessed.

Results:

During precleaning both PBS and 1% (v/v) Neodisher Mediclean Forte were able to desorb bacteria, but neither proved superior. After precleaning only sodium dodecyl sulfate could desorb bacteria.

Conclusions:

Flushing during precleaning is an essential step for reducing adhering luminal bacteria, and sodium dodecyl sulfate is a promising detergent for bacterial desorption from duodenoscope channels after precleaning.

Information

Type
Original Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America
Figure 0

Fig. 1.The current steps of duodenoscope reprocessing.32 Green block: the duodenoscopic procedure; blue blocks: current steps of the reprocessing procedure; orange block: additional step evaluated in this study.

Figure 1

Fig. 2.Desorption of adhering bacteria during interventions with 2 hours of flow compared with flow chambers left empty for 2 hours. (A) The difference between the mean number of adhering bacteria prior to precleaning compared to the number of adhering bacteria after an intervention. (B) The difference between the mean number of adhering bacteria after precleaning compared to the number of adhering bacteria after intervention. The dotted line represents no intervention. *P < .05 was considered significant.

Figure 2

Fig. 3.Images of adhering K. pneumoniae to FEP. (A) Bacteria randomly adhering on FEP before application of microbubbles. (B) Clustering of adhering bacteria after application of microbubbles.

Figure 3

Table 1.Remaining Adhering Viable Bacteria on FEP After the Interventions

Figure 4

Table 2.Duodenoscope Contamination Model Characteristics

Supplementary material: File

Heuvelmans et al. supplementary material

Heuvelmans et al. supplementary material 1

Download Heuvelmans et al. supplementary material(File)
File 100.9 KB
Supplementary material: File

Heuvelmans et al. supplementary material

Heuvelmans et al. supplementary material 2

Download Heuvelmans et al. supplementary material(File)
File 34.8 KB