Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-06T15:29:04.278Z Has data issue: false hasContentIssue false

Experimental study of diffusiophoresis in a cellular flow

Published online by Cambridge University Press:  04 November 2025

Florence Raynal*
Affiliation:
Laboratoire de Mécanique des Fluides et d’Acoustique, CNRS UMR 5509, École centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1 , Écully CÉDEX 69134, France
Menghua Zhao
Affiliation:
Laboratoire de Mécanique des Fluides et d’Acoustique, CNRS UMR 5509, École centrale de Lyon, INSA Lyon, Université Claude Bernard Lyon 1 , Écully CÉDEX 69134, France Laboratoire de Physique, ENS de Lyon, CNRS, Lyon F-69342, France
Romain Volk
Affiliation:
Laboratoire de Physique, ENS de Lyon, CNRS, Lyon F-69342, France
*
Corresponding author: Florence Raynal, florence.raynal@ec-lyon.fr

Abstract

In this paper, we study experimentally the dispersion of colloids in a two-dimensional, time-independent, Rayleigh–Bénard flow in the presence of salt gradients. Due to the additional scalar, the colloids do not follow exactly the Eulerian flow field, but have a (small) extra velocity $\boldsymbol{v}_{{dp}} = D_{{dp}}\, \boldsymbol{\nabla }\log C_s$, where $D_{{dp}}$ is the phoretic constant, and $C_s$ is the salt concentration. Such a configuration is motivated by the theoretical work by Volk et al. (2022, J. Fluid Mech., vol. 948, A42), which predicted enhanced transport or blockage in a stationary cellular flow depending on the value of a blockage coefficient. By means of high dynamical range light-induced fluorescence, we study the evolution of the colloids concentration field at large Péclet number. We find good agreement with the theoretical work, although a number of hypotheses are not satisfied, as the experiment is non-homogeneous in space, and intrinsically transient. In particular, we observe enhanced transport when salt and colloids are injected at both ends of the Rayleigh–Bénard chamber, and blockage when colloids and salt are injected together and phoretic effects are strong enough.

Information

Type
JFM Papers
Copyright
© The Author(s), 2025. Published by Cambridge University Press
Figure 0

Figure 1. The flow in the Rayleigh–Bénard cell (with length $L_{\textit{tot}}={150}\,\textrm {mm}$, height $h={7.5}\,\textrm {mm}$, width $w={15}\,\textrm {mm}$) is set above the onset of the first instability and below the second instability using a heating thermal Kapton heater at the bottom and a liquid cooler at the top. Two injection sites are located on each side of the cell. The vertical walls are made of transparent acrylic glass. The fluorescent species (whether colloids or fluorescein) is injected through site (1), and its dispersion is followed using a laser sheet.

Figure 1

Figure 2. $(a)$ Magnitude $\|\boldsymbol{u}\|$ of the velocity field measured by PIV for $\Delta T = 1.37\,^\circ\text{C}$. $(b)$ Vertical velocity profile along the centreline inside the RB chamber for several values of the temperature difference $\Delta T$, from $1.00\,^\circ \textrm {C}$ to $1.49\,^\circ \textrm {C}$. $(c)$ Maximum of the velocity magnitude $U$ as a function of $\Delta T$.

Figure 2

Figure 3. $(a)$ Raw image obtained using the LIF set-up and exposure time $t_e=50\,\textrm {ms}$, $10\,\textrm {h}$ after colloid injection. $(b)$ Camera calibration curves: squares record intensity measured with increasing homogeneous fluorescein concentration in $2.5\ \textrm {ml}$ cuvettes for two exposure times, $t_e=5$ and $50\,\textrm {ms}$. The straight lines correspond to linear fits derived in the linear range $I \leqslant 44\,000$ ($60\,\%$ of the dynamical range). $(c)$ Comparison of $x$-profiles of recorded intensity averaged over the vertical coordinate $y$ and two exposure times. Blue dots show raw intensity profile measured with $t_e=50$ ms. The red line shows intensity profile measured with $t_e=5$ ms, transformed using the linear transformation $\mathcal{T}[I]=\gamma I + \kappa$, with $\gamma = 10.2$ and $\kappa = - 951$. $(d)$ The $x$-profiles of concentration averaged over the vertical coordinate $y$ built using the HDR procedure and calibration curves obtained in the chamber with known (homogeneous) colloid concentration. The dashed red line indicates without correction for exponential attenuation through the chamber. The blue solid line indicates with compensation for exponential attenuation.

Figure 3

Table 1. Diffusion coefficient for fluorescein, salt (LiCl) and colloids, and corresponding Péclet number of the flow $\textit{Pe}=UL/D$ for two extreme temperature differences, $\Delta T = 1.0\,^\circ \textrm {C}$ and $\Delta T=1.5\,^\circ \textrm {C}$. Here, $D$ is a generic diffusion coefficient, and $D_{\textit{f}}$, $D_s$, $D_c$ are the corresponding values for fluorescein, salt and colloids, respectively.

Figure 4

Figure 4. $(a)$ Fluorescein concentration profile as a function of time for $\Delta T=1.10\pm 0.06\,^\circ \textrm {C}$ ($\textit{Pe}_{\textit{f}}=6270$). $(b)$ Three concentration profiles extracted from (a) (corresponding to the three horizontal lines on this figure) for $t={4000}\ \text{s}$ (${1}\,\textrm {h}\,{7}\,\min$), $t={16\,000}\ \text{s}$ (${4}\,\textrm {h}\,{27}\,\min$) and $t={32\,000}\ \text{s}$ (${8}\,\textrm {h}\,{53}\,\min$). Solid lines correspond to Gaussian functions with the same variance according to (3.1).

Figure 5

Figure 5. Typical dispersion curves for fluorescein and different values of the temperature difference $\Delta T=0.99,1.02,1.47$ (corresponding to Péclet numbers of the fluorescein $\textit{Pe}_{\textit{f}}$ between $5760$ and $8630$). As found previously in Solomon & Gollub (1988b), the global behaviour corresponds to an effective diffusion, with an effective diffusion coefficient given by (3.4).

Figure 6

Figure 6. Reference case (colloids alone). $(a)$ Normalised colloid concentration profile as a function of time for $\Delta T=1.1\,^\circ \textrm {C}$ ($\textit{Pe}_c=3.9\times 10^5$). $(b)$ Three concentration profiles extracted from (a) (corresponding to the three horizontal lines on this figure) for $t={15\,000}\ \text{s}$ (${4}\,\textrm {h}\,{10}\,\min$), $t={30\,000}\ \text{s}$ (${8}\,\textrm {h}\,{20}\,\min$) and $t={60\,000}\ \text{s}$ (${16}\,\textrm {h}\,{40}\,\min$). $(c)$ Dispersion curves $\langle x^2 \rangle _c(t)$ obtained with colloids and temperature difference $\Delta T \in [1,1.33]$$\,^\circ$C. The darker the symbol, the larger the colloid Péclet number. The two dashed lines stand for the theoretical predictions for the spreading of neutral particles of the same size as the colloids, calculated using (3.4) transposed to colloids, $\langle x^2\rangle _c(t)\approx \langle x^2\rangle _c(0)+2\times B\times D_c \sqrt {\textit{Pe}_c}\times t$, with $\sqrt {\langle x^2\rangle _c(0)}\approx 12\,\textrm {mm}$ and $B=0.5$ as for fluorescein (3.4), for $\Delta T=1\,^\circ \textrm {C}$ and $\Delta T=1.5\,^\circ \textrm {C}$.

Figure 7

Figure 7. Typical image of a reference case ($\Delta T=1.1\,^\circ \textrm {C}$ and $t=43\,000\,\textrm {s}=12\,\textrm {h}$).

Figure 8

Figure 8. Salt distribution (numerical simulations) in the stationary regime, for a constant horizontal mean gradient $\boldsymbol{G}=G\,\boldsymbol{e}_x$; here, ${\textit{Pe}}_s=3140$, $G=1$, and the size of a cell is $L=\pi$. $(a)$ Stationary salt concentration field $C_s$ in two consecutive cells, with an imposed constant mean gradient $\boldsymbol{G}=G\,\boldsymbol{e}_x$; the white arrows represent the cellular velocity field. $(b)$ Horizontal profile along the horizontal dashed line in (a). $(c)$ Two vertical profiles along the vertical dashed lines. The salt concentration is approximately constant in the cells, except around the vertical and horizontal separatrixes.

Figure 9

Figure 9. $(a)$ Schematic displacement of a particle in the salt gradient (light blue region) around the vertical ascending separatrix $x=L$. The Eulerian velocity field $\boldsymbol{u}$ is vertical and ascending, and $\boldsymbol{v}_{{dp}}$ is horizontal; the total velocity of particles around the vertical separatrixes is therefore $\boldsymbol{v}_t=\boldsymbol{u}+\boldsymbol{v}_{{dp}}$, with $\boldsymbol{u}\approx U\, \boldsymbol{e}_y$. Particles that change cell are located on the grey strip of width $\ell _d$. $(b)$ Schematic location of particles that change cell, in grey, for cells located between $x=0$ and $x=2L$; an example of a trajectory is shown in red. Outside this grey strip, the particles remain trapped in their cells. From Volk et al. (2022).

Figure 10

Table 2. Summary of the differences between theory and experimental conditions. For the experiment, the index $i=1,2$ stands for the injection hole of the salt (see figure 1), with $L^{(1)}=0$ and $L^{(2)}=L_{\textit{tot}}$.

Figure 11

Figure 10. Space-time diagram for the blockage coefficient $R$ in the salt-out configuration (4.7) for $\Delta T=1\,^\circ \textrm {C}$, with the experimental data $D_s =1360$$\unicode{x03BC} \textrm{m}^2\, \textrm{s}^{-1}$, $D_c = 2$$\unicode{x03BC} \textrm{m}^2\, \textrm{s}^{-1}$ and $D_{{dp}} = 290\, \unicode{x03BC} \textrm{m}^2\, \textrm{s}^{-1}$ ($D_{{dp}}/\sqrt {D_cD_s}\approx 5.56$). Values higher than $4$, which correspond to possible blockage, are shown in yellow. The salt is released at time $\tau =0$, while the colloids are released a time $t_0$ later; we set $t=\tau -t_0$ so as to have the colloids released at $t=0$. The dashed lines indicate the times at which the colloids are released in the experiments presented: black dashed line for $t_0=6\,\textrm {h}$; white dashed line for $t_0=17\,\textrm {h}$.

Figure 12

Figure 11. Salt-out configuration: first, salt (LiCl, non-fluorescent) is introduced through injection site (2) at $t=-t_0$; then colloids (fluorescent) are introduced through injection site (1) at $t=0$. The delay $t_0$ must be long enough so that some salt has reached the other side of the cell when colloids are introduced. The two horizontal bold arrows show the transient effects felt by the colloids after introduction: they naturally travel towards the right, as showed in the reference case (common transport); they are also attracted by salt and therefore furthermore travel towards the right (salt attraction).

Figure 13

Figure 12. Salt-out case. (a,c) Colloid concentration profile as a function of time for two different time lags $t_0$. (b,d) Corresponding $\langle x\rangle _c$ as a function of time (magenta curve). The dash-dotted blue line is the theoretical prediction (4.16). For comparison, the black curve is a reference case (colloids with no salt) for a similar Péclet number. Here, (a,b) $t_0={6}\,\textrm {h}$ ($\Delta T=1.03\,^\circ \textrm {C}$) and (c,d) $t_0={17}\,\textrm {h}$ ($\Delta T=1.1\,^\circ \textrm {C}$).

Figure 14

Figure 13. Salt-in configuration: fluorescent colloids, together with non-fluorescent LiCl salt, are introduced through injection site (1) at $t=0$. The two horizontal bold arrows show the transient effects felt by the colloids after introduction: they naturally tend to travel towards the right, as shown in the reference case (common transport); they are also attracted by salt and therefore also tend to travel towards the left. There is thus a competition at small time between the two processes.

Figure 15

Figure 14. Space–time diagram for the blockage coefficient $R$ in the salt-in configuration for $\Delta T=1\,^\circ \textrm {C}$. Values higher than $4$, which correspond to possible blockage, are shown in yellow. Both salt and colloids are released at time $t=0$ (see figure 13).

Figure 16

Figure 15. Salt-in configuration. (a,c,e) Normalised concentration profiles in $x$, together with (b,d,f) their average position $\langle x\rangle _c(t)$, for three different values of the temperature difference $\Delta T$, increasing from top to bottom: (a,b) $\Delta T=1.02\,^\circ \textrm {C}$, (c,d) $\Delta T=1.26\,^\circ \textrm {C}$, (e,f) $\Delta T=1.45\,^\circ \textrm {C}$. The solid line has equation $x=1.43 \,\langle x^2 \rangle _s(t)/L$ (from (4.18)), with $L=9.4\,\textrm {mm}$ and $\langle x^2 \rangle _s(t) \approx 9.4^2 + 13 \times 10^{-4} \sqrt {\textit{Pe}_s} t$ (from (3.6)). Blockage may happen whenever the profile crosses this line (necessary condition). From the mean profiles $\langle x^2\rangle _c(t)$ in (b,d,f), it is visible that blockage lasts the longest for the largest temperature difference $\Delta T$ (largest Péclet number). The dashed line in (e) at time $t=1.5\,\textrm {h}$ is the time corresponding to the snapshot of figure 16.

Figure 17

Figure 16. Blockage situation for $\Delta T=1.45\,\,^\circ \textrm {C}$ and $t=5400\,\textrm {s}=1.5\,\textrm {h}$ (dashed line in figure 15$e$). The coefficient $R$ increases from left to right, following (4.17).