Transcatheter closure of a right pulmonary artery to left atrium fistula using multi-modality image fusion guidance

Published online by Cambridge University Press:  04 December 2024

Natalie Soszyn*
Affiliation:
Division of Cardiology, Department of Pediatrics, Heart Institute, Children’s Hospital Colorado, University of Colorado Denver, Aurora, CO, USA
Edward A. Gill
Affiliation:
University of Colorado School of Medicine, University of Colorado Hospital, Aurora, CO, USA
Jenny E. Zablah
Affiliation:
Division of Cardiology, Department of Pediatrics, Heart Institute, Children’s Hospital Colorado, University of Colorado Denver, Aurora, CO, USA
Gareth J. Morgan
Affiliation:
Division of Cardiology, Department of Pediatrics, Heart Institute, Children’s Hospital Colorado, University of Colorado Denver, Aurora, CO, USA
*
Corresponding author: Natalie Soszyn; Email: nsoszyn@gmail.com
Rights & Permissions [Opens in a new window]

Abstract

We present the case of 53-year-old woman with a late diagnosis of an right pulmonary artery-left atrium fistula who underwent transcatheter device closure using multi-modality imaging for pre-procedural planning and procedural guidance.

Information

Type
Brief Report
Copyright
© The Author(s), 2024. Published by Cambridge University Press
Figure 0

Figure 1. Cardiac CT was used for pre-procedural guidance and delineates the location of the RPA-LA communication (represented by the yellow line). The cardiac CT was then used to create a 3D reconstruction using virtual reality for segmentation. Notably, the 3D reconstruction using the cardiac CT dataset overestimated the size of the communication between the RPA and LA.

Figure 1

Figure 2. A bubble study was performed in the SVC which demonstrated late filling of the LA with bubbles in a couple of cardiac cycles after right heart opacification via a communication from the RPA (green arrow). (Panel A) Real-time TOE was overlaid onto live fluoroscopy using EchoNavigator software to demonstrate the location of the communication and aid in device deployment. The blue arrow demonstrates the AVP-IV device during and after deployment from the RPA on 2-D and 3-D TOE (Panel B and C).

Figure 2

Table 1. Haemodynamic assessment prior to RPA-LA fistula closure

Figure 3

Figure 3. A 3D CT reconstruction was fused with live fluroscopy using VesselNavigator (Phillips, Best, The Netherlands) to guide the procedure.