Thermal convection with mixed thermal boundary conditions: effects of insulating lids at the top

Published online by Cambridge University Press:  15 March 2017

Fei Wang
Affiliation:
Department of Physics, The Chinese University of Hong Kong, Shatin, Hong Kong, China
Shi-Di Huang
Affiliation:
Department of Physics, The Chinese University of Hong Kong, Shatin, Hong Kong, China
Ke-Qing Xia*
Affiliation:
Department of Physics, The Chinese University of Hong Kong, Shatin, Hong Kong, China
*
†Email address for correspondence: kxia@cuhk.edu.hk

Abstract

The effects of insulating lids on the convection beneath were investigated experimentally using rectangular convection cells in the flux Rayleigh number range $2.3\times 10^{9}\leqslant Ra_{F}\leqslant 1.8\times 10^{11}$ and cylindrical cells in the range $1.4\times 10^{10}\leqslant Ra_{F}\leqslant 1.2\times 10^{12}$ with the Prandtl number $Pr$ fixed at 4.3. It is found that the presence of the insulating lids leads to reduction of the global heat transfer efficiency as expected, which primarily depends on the insulating area but is insensitive to the detailed insulating patterns. At the leading-order level, the magnitude of temperature fluctuations in the bulk fluid is, again, found to be insensitive to the insulating pattern and mainly depends on the insulating area; while the temperature probability density function in the bulk is essentially invariant with respect to both the insulating area and the spatial pattern of the lids. The flow dynamics, on the other hand, is sensitive to both the covering area and the spatial distribution of the lids. At fixed $Ra_{F}$ , the flow strength is found to increase with increasing insulating area so as to transfer the same amount of heat through a smaller cooling area. Moreover, for a constant insulating area, a symmetric insulating pattern results in a symmetric flow pattern, i.e. double-roll structure; whereas an asymmetric insulating pattern leads to asymmetric flow, i.e. single-roll structure. It is further found that the symmetry breaking of the insulating pattern leads to a stronger flow that enhances the horizontal velocity more than the vertical velocity.

Information

Type
Rapids
Copyright
© 2017 Cambridge University Press 
Figure 0

Figure 1. A schematic drawing of the rectangular cell with a CAC configuration for the top boundary. See text for details.

Figure 1

Figure 2. Schematic drawings of (a) the convection cell with homogeneous boundary condition at the top, i.e. $\unicode[STIX]{x1D709}=0$, and (b–e) convection cells with different insulating patterns at the top plates. Each pattern is named as ‘insulating area $+$ insulating location’. For example, ‘$1/4$ centre’ means that the insulating material covers the central region with an area equal to $1/4$ of the total area of the top plate.

Figure 2

Figure 3. (a) The global heat transfer efficiency $Nu$ as a function of the flux Rayleigh number $Ra_{F}$ for different configurations of the rectangular cell. (b) The corresponding data normalised by $Nu$ in the ‘CCC’ case. (c) $Nu$ and (d) normalised $Nu$ for the cylindrical cells. The dashed line with the value $Nu/Nu_{Homo.}=1$ in (d) is plotted for reference.

Figure 3

Figure 4. The global heat transfer efficiency $Nu$ as a function of the Rayleigh number $Ra$ for different configurations in (a) the rectangular cells and (b) the cylindrical cells. The solid lines correspond to power-law fittings with the fitting parameters listed in table 1.

Figure 4

Table 1. Fitting parameters of the $Nu{-}Ra$ scaling in figure 4.

Figure 5

Figure 5. (a) The bulk temperature r.m.s. $\unicode[STIX]{x1D70E}_{T}$ normalised by the global temperature difference $\unicode[STIX]{x0394}T$ as a function of $Ra_{F}$. (b) The probability density functions (PDFs) of the normalised bulk temperature fluctuations at $Ra_{F}=1.1\times 10^{11}$ for five different configurations of the rectangular cell. The green solid and red dashed lines indicate the exponential distribution and Gaussian distribution, respectively.

Figure 6

Figure 6. (a–e) Time-averaged velocity fields for five configurations at $Ra_{F}=1.1\times 10^{11}$. The scale bar represents $(U^{2}+V^{2})^{1/2}$ in units of $\text{cm}~\text{s}^{-1}$. (f–j) The corresponding contour maps of the stream function with the scale bar in unit of $\text{cm}^{2}~\text{s}^{-1}$. The stream function values are set to zero at the cell boundaries. The contour interval is $0.6~\text{cm}^{2}~\text{s}^{-1}$. Note that the ‘CAC’ and ‘ACA’ configurations correspond to symmetric insulating patterns ($\unicode[STIX]{x1D6EC}=0$) at the top, while the ‘CCA’ and ‘CAA’ configurations correspond to asymmetric insulating patterns ($\unicode[STIX]{x1D6EC}=1$).

Figure 7

Table 2. Flow-field quantities obtained from the PIV-measured time-averaged velocity field for different configurations in the rectangular cell at $Ra_{F}=1.1\times 10^{11}$. $\unicode[STIX]{x1D709}$: fractional insulating area; $\unicode[STIX]{x1D6EC}$: symmetry parameter with $\unicode[STIX]{x1D6EC}=0$ ($\unicode[STIX]{x1D6EC}=1$) standing for symmetric (asymmetric) insulating pattern; structure: indicating whether the flow field has a single-roll (SR) or a double-roll (DR) structure; $V_{max}$: the maximum value of the velocity magnitude; KE: mean kinetic energy per unit mass $\mathit{KE}=(U^{2}+V^{2})/2$; $\unicode[STIX]{x1D6F9}_{max}$ ($\unicode[STIX]{x1D6F9}_{min}$): the maximum (minimum) stream function with positive (negative) value stands for overturning in the counter-clockwise (clockwise) direction.

Figure 8

Figure 7. (a) Horizontal cuts of the vertical velocity $V(x)$ at $Y=0$  cm. (b) Vertical cuts of the horizontal velocity $U(y)$ at $X=0$  cm for CCA and CAA cases, $X=-L/4$ for CAC case, and $X=L/4$ for the ACA case.