Hostname: page-component-74656f9884-rdgjk Total loading time: 0 Render date: 2026-11-08T16:42:32.387Z Has data issue: false hasContentIssue false

Hybrid approach for end-stage heart failure treatment in a 6-month-old baby

Published online by Cambridge University Press:  17 March 2023

Biagio Castaldi*
Affiliation:
Department of Women’s and Children’s Health, University of Padua, Italy
Massimo Padalino
Affiliation:
Department of Cardiac Thoracic and Vascular Sciences and Public Health, University of Padua, Italy
Domenico Sirico
Affiliation:
Department of Women’s and Children’s Health, University of Padua, Italy
Alvise Guariento
Affiliation:
Department of Cardiac Thoracic and Vascular Sciences and Public Health, University of Padua, Italy
Vladimiro Vida
Affiliation:
Department of Cardiac Thoracic and Vascular Sciences and Public Health, University of Padua, Italy
Giovanni Di Salvo
Affiliation:
Department of Women’s and Children’s Health, University of Padua, Italy
*
Author for correspondence: Biagio Castaldi, Pediatric Cardiology Unit, Department of Women’s and Children’s Health -University of Padua, Via Giustiniani 3, 35128 Padova, Italy. Tel: +390498213558. E-mail: b.castaldi@yahoo.it
Rights & Permissions [Opens in a new window]

Abstract

A 6-month-old baby girl, with a history of 2 months of intensive care management and two episodes of cardiac arrest, was transferred from another European country to initiate the “Giessen approach” for end-stage heart failure in children. At the admission, left ventricular ejection fraction was 20%. Severe mitral valve regurgitation and severe left atrial dilatation were present. Right ventricular function was preserved, and tricuspid valve regurgitation was mild. As a result, the patient underwent surgical pulmonary artery banding. Additionally, unloading of the left atrium was achieved by implanting an 8 mm atrial flow regulator device through a hybrid per-atrial approach. Two months after the procedure, the patient was progressively weaned from the inotropes and transferred to the ward.

Information

Type
Brief Report
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© University of Padua, 2023. Published by Cambridge University Press
Figure 0

Figure 1. Hybrid approach for AFR implantation in 6-month-old infant. (a) Atrial septum from a transverse view. The total septal length was 30 mm. (b) The atrial septum was punctured with a 18 Ga, than stabilised a SV5 guidewire in the left atrium. On the guidewire, an 8x20 mm Sterling balloon was inflated (green arrows). (c) After the inflation, a 4 mm atrial septal defect was obtained. (d) An 11 Fr Terumo sheath was advanced in the atrial septal defect, and the left disk was deployed in the dilated left atrium. (e) By keeping a gentle traction on the system, the right disk was opened. Once verified the device stability, the device was deployed. (f) Color-Doppler demonstrated the left to right shunt. The diameter was 7 mm.